Skip to main content
Found 3,957 inverters
Model Rated AC Type Phase Euro eff. MPPT Max DC kg/kW Warranty
TSOL-MS1800 1.8 kW Microinverter 1-ph 96.5% 4 60 V 3.1 kg/kW 12 yr
EVT1800SE 1.8 kW Microinverter 1-ph - 4 60 V 2.7 kg/kW 15 yr
HMS-1800DW-4T 1.8 kW Microinverter 1-ph - 2 65 V 2.5 kg/kW -
HMS-1800-4WB 1.8 kW Microinverter 1-ph - 4 65 V 3.1 kg/kW -
HYX-M1800-S/HYX-M1800-SW 1.8 kW Microinverter 1-ph - 4 65 V 2.8 kg/kW 12 yr
HMT-1800-4T-208-NA 1.728 kW Microinverter 3-ph - 2 65 V 3.4 kg/kW -
HMS-1800-4T-NA 1.66 kW Microinverter 1-ph - 4 65 V 3.3 kg/kW -
Growatt 1500-S 1.6 kW Grid-tie 1-ph 97.0% 1 550 V 4.0 kg/kW 5 yr
NEO 1600M-X2 1.6 kW Microinverter 1-ph - 4 60 V 3.2 kg/kW 12 yr
GW1600-MIS 1.6 kW Microinverter 1-ph - 4 65 V 3.3 kg/kW -
SOFAR 1600TL-G3 1.6 kW Grid-tie 1-ph 97.2% 1 550 V 3.9 kg/kW -
SOFAR 1.6KTL2-G3 1.6 kW Grid-tie 1-ph 96.7% 1 550 V 3.8 kg/kW -
S1600S 1.6 kW Microinverter 1-ph 95.4% - 60 V 4.7 kg/kW -
SUN1600G3-EU-230 1.6 kW Microinverter 1-ph - 4 60 V 3.2 kg/kW 10 yr
ISolar SPL 2K 1.6 kW Off-grid 1-ph - - - 4.0 kg/kW -
ISolar MLV 2K 24V 1.6 kW Off-grid - - - - 6.6 kg/kW -
ISolar MLV 2K 48V 1.6 kW Off-grid - - - - 6.9 kg/kW -
POW-HVM2.0H-12V 1.6 kW Off-grid 1-ph - 1 450 V 2.8 kg/kW -
POW-HVM2H-12V-N 1.6 kW Off-grid - - - - 2.9 kg/kW -
C 12/2000/80 1.6 kW Off-grid 1-ph - - - 7.5 kg/kW -
Reading this table

Rated AC is the continuous output

The nominal AC power from the datasheet, usually the number in the model name. Where only a maximum is published, that is shown instead.

Euro efficiency, not peak

The figure weighted across part loads, which sits below the peak efficiency a datasheet prints first.

kg per kW

Weight divided by rated power, so a 10 kW and a 3 kW unit can be compared for what they cost to mount.

A dash means no data

The manufacturer did not publish it. We never estimate a missing value.