Skip to main content
Active Schneider Electric Clear all Found 16 inverters
Model Rated AC Type Phase Euro eff. MPPT Max DC kg/kW Warranty
CL125E 125 kW Grid-tie 3-ph 98.7% 1 1500 V 0.6 kg/kW -
CL-60E 66 kW Grid-tie 3-ph 98.5% 1 1000 V 1.0 kg/kW -
CL-60A 63.4 kW Grid-tie 3-ph - 1 1000 V 1.1 kg/kW -
CL25000 NA 25 kW Grid-tie 3-ph - 2 1000 V 2.2 kg/kW -
CL25000 E 25 kW Grid-tie 3-ph 98.0% 2 1000 V 2.2 kg/kW -
CL20000 E 20 kW Grid-tie 3-ph 98.0% 2 1000 V 2.7 kg/kW -
TL 20000 E 20 kW Grid-tie 3-ph 97.5% 2 1000 V 3.4 kg/kW 5 yr
CL18000 NA 18 kW Grid-tie 3-ph - 2 1000 V 3.0 kg/kW -
TL 15000 E 15 kW Grid-tie 3-ph 97.3% 2 1000 V 4.5 kg/kW 5 yr
XW+ 8548 E 6.8 kW Hybrid 1-ph - - 64 V 8.1 kg/kW -
XW+ 6848 NA 6.8 kW Hybrid 1-ph - - 60 V 8.1 kg/kW -
XW+ 7048 E 5.5 kW Hybrid 1-ph - - 64 V 9.7 kg/kW -
XW+ 5548 NA 5.5 kW Hybrid 1-ph - - 60 V 9.7 kg/kW -
RL 5000 E 5 kW Grid-tie 1-ph 97.0% 2 550 V 4.8 kg/kW 5 yr
RL 4000 E 4 kW Grid-tie 1-ph 97.0% 2 550 V 5.2 kg/kW 5 yr
RL 3000 E 3 kW Grid-tie 1-ph 97.0% 2 550 V 6.7 kg/kW 5 yr
Reading this table

Rated AC is the continuous output

The nominal AC power from the datasheet, usually the number in the model name. Where only a maximum is published, that is shown instead.

Euro efficiency, not peak

The figure weighted across part loads, which sits below the peak efficiency a datasheet prints first.

kg per kW

Weight divided by rated power, so a 10 kW and a 3 kW unit can be compared for what they cost to mount.

A dash means no data

The manufacturer did not publish it. We never estimate a missing value.