Skip to main content

Schneider Electric CL18000 NA

18 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
18.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
2
Typical · median 2
Max DC (V)
1000
Typical · median 1000 V
Weight (kg)
54.0
Weak · 16.0 kg above median
Warranty (yrs)
-
Not published

The Conext CL-NA series from Schneider Electric consists of three-phase transformerless inverters built for commercial and industrial PV systems rated at 18 and 25 kVA. Their standout feature is a wide MPPT voltage range, which allows flexible string design and efficient energy harvest even under variable irradiance conditions, reducing losses and improving project LCOE. Thanks to a fan-cooled design, these units maintain stable performance across a broad ambient temperature range, a key advantage when mounted on warehouse roofs, retail buildings, or agricultural sites where thermal conditions can be demanding. The integrated DC disconnect simplifies safe servicing and shortens installation time, helping to lower BoS costs. UL 1741 certification confirms compliance with grid-safety standards, which matters for installers working in the North American market and on projects requiring strict documentation. Built-in Modbus communication enables integration with monitoring and energy-management systems, giving operators full real-time visibility into inverter performance. This makes the series a solid choice for installation companies seeking a proven, commercial-grade inverter with low operating costs.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.0% Not published -
MPPT trackers 2 2 Typical 168
Max DC input voltage 1000 V 1000 V Typical 229
Weight per kW 3.0 1.8 Weak · bottom 18% 491
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 18 kW Continuous output
Max apparent power 18.00 kVA
Phases Three-phase
Nominal AC voltage 480 V 244 - 305 V / 422 - 528 V
Max AC current 25.0 A
Grid frequency 60 Hz Range 60 +/- 3 Hz
Power factor 0.8 lead to 0.8 lag
Harmonic distortion (THD) 3.0 %
Max DC input power 19.00 kW DC/AC ratio 1.06
Max DC voltage 1000 V Caps the string length
MPPT voltage range 300 to 800 V
MPPT trackers 2 4 strings each
Max short-circuit current per MPPT 36.0 A Must exceed the panel's Isc
Max efficiency 98.0 % Best single operating point
CEC efficiency 97.5 % California Energy Commission weighting
Dimensions 714 × 674 × 268 mm Height × width × depth
Weight 54.0 kg 3.0 kg per kW
Enclosure TYPE 4
Cooling forced-air
Noise 55 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 2000 m
Interfaces EthernetDisplay
Protocols RS485 (MODBUS RTU)Ethernet / MODBUS TCPUSBdry contact
Protection AFCIDC switchSurge protection
Certifications UL1741IEEE 1547.1CSA C22.2 107.1-01FCC Part 15

Pros and cons

5 positive · 3 caution
What owners get
High 98.4% conversion efficiency

Schneider Electric's official datasheet lists 98.4% peak and 98.0% CEC efficiency for the 25 kVA model (98.0%/97.5% for the 18 kVA model), a result comparable to top-tier commercial inverters of its era and one that minimizes DC/AC conversion losses.

Wide MPPT voltage range

The 250-1000 V MPPT operating range (300-800 V full-power for the 18 kVA model, 500-800 V for the 25 kVA model) with 2 MPPT trackers and 4 strings per MPPT allows flexible string design across varying module configurations and roof orientations.

UL 1741 certification and grid compliance

UL 1741 certification confirms compliance with North American grid-safety standards, easing approval for commercial installations that require rigorous documentation, particularly in the North American market.

Integrated DC disconnect and Modbus

A built-in DC disconnect reduces the number of BoS components and installation time, while native Modbus communication enables integration with SCADA and monitoring systems without additional protocol converters.

Low noise level under 55 dBA

Per the official datasheet, acoustic emissions stay below 55 dBA, which is advantageous for installations near offices or retail buildings where fan-cooled unit noise can be a concern.

Trade-offs
Discontinued product line

The Conext CL-NA series (released 2015) is formally discontinued by Schneider Electric, as confirmed on the manufacturer's discontinued-products list. This means limited availability of spare parts and warranty service, and new deployments require selecting a replacement product.

Fan cooling instead of natural convection

Unlike newer tier-1 commercial inverters using convection or fanless cooling, the CL-NA relies on fans, increasing the risk of mechanical component failure and adding long-term maintenance costs.

No published end-of-life support date

Schneider has not published a formal end-of-life date or a designated replacement product for the CL-NA, making long-term service planning difficult for commercial installations relying on this series.

Inverter Power Euro eff. MPPT Weight Difference
Schneider Electric CL18000 NA 18 kW - 2 54.0 kg You are here
SUN-18K-G04P3-EU-CM2-LV 18 kW 98.1% - 28.7 kg 25.3 kg lighter
SUN-18K-G05 18 kW 98.0% 2 20.0 kg 34.0 kg lighter
SUN-18K-G02 18 kW 97.8% 2 28.0 kg 26.0 kg lighter
SUN-18K-G06P3-EU-AM2 18 kW 97.7% 2 12.7 kg 41.3 kg lighter
SUN-18K-G04-LV 18 kW - 2 28.7 kg 25.3 kg lighter
Fronius Verto 17.5 17.5 kW 98.3% 4 35.2 kg -0.5 kW, +2 MPPT, 18.8 kg lighter
Symo Advanced 17.5-3-M 17.5 kW 97.6% 2 42.0 kg -0.5 kW, 12.0 kg lighter
Fronius Symo 17.5-3 480 17.5 kW - - 43.4 kg -0.5 kW, 10.6 kg lighter

About the Conext CL-NA series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Is the Conext CL-NA series still available for purchase?
No, Schneider Electric has discontinued the Conext CL-18/25 NA series and officially lists it as a discontinued product. New units are no longer offered, though distributors may still have remaining stock. Service and technical support for already-installed units remain available, but for new projects it's worth considering a current model from Schneider Electric's lineup.
What is the MPPT voltage range on the Conext CL-NA 18 kVA and 25 kVA inverters?
The 18 kVA model operates at full power within a 300-800 V MPPT range, while the 25 kVA variant has a narrower full-power range of 500-800 V. Both units share a wider operating range of 250-1000 V and a maximum open-circuit voltage of 1000 V. This spacing allows installers to design longer PV strings and flexibly adapt the layout to available roof space.
What is the difference between the 18 kVA and 25 kVA models in the Conext CL-NA series?
The main difference is rated power - 18.0 kVA versus 25.0 kVA at the same 277/480 V nominal output. The 25 kVA model has a narrower full-power MPPT range (500-800 V versus 300-800 V on the 18 kVA unit) due to higher string input current. The choice depends on PV system size and panel count - larger commercial sites typically use the 25 kVA variant.
Is the Conext CL-NA inverter suitable for mounting on warehouse or industrial roofs?
Yes, thanks to fan cooling the unit maintains stable operation even in the demanding thermal conditions typical of warehouse and retail roofs, where metal roofing can get very hot in summer. An integrated DC disconnect simplifies safe servicing at height, and the transformerless three-phase design is well suited to commercial installations in the 18-25 kVA class.
Does the Conext CL-NA inverter have UL 1741 certification for use in the US or Canada?
Yes, the Conext CL-NA series carries UL 1741 certification, confirming compliance with the safety and grid-interconnection requirements used across North America. This matters for installers handling commercial projects in the US and Canada, where UL 1741 compliance documentation is typically required when submitting an installation to the local utility.
Does the Conext CL-NA inverter support Modbus communication for remote monitoring?
Yes, the unit offers Modbus communication, allowing integration with energy monitoring and management systems (SCADA, BMS platforms). Operators can read real-time operating parameters, instantaneous power, alarm states, and energy production data, which simplifies managing a larger fleet of inverters across commercial and industrial installations.