The Conext CL-NA series from Schneider Electric consists of three-phase transformerless inverters built for commercial and industrial PV systems rated at 18 and 25 kVA. Their standout feature is a wide MPPT voltage range, which allows flexible string design and efficient energy harvest even under variable irradiance conditions, reducing losses and improving project LCOE. Thanks to a fan-cooled design, these units maintain stable performance across a broad ambient temperature range, a key advantage when mounted on warehouse roofs, retail buildings, or agricultural sites where thermal conditions can be demanding. The integrated DC disconnect simplifies safe servicing and shortens installation time, helping to lower BoS costs. UL 1741 certification confirms compliance with grid-safety standards, which matters for installers working in the North American market and on projects requiring strict documentation. Built-in Modbus communication enables integration with monitoring and energy-management systems, giving operators full real-time visibility into inverter performance. This makes the series a solid choice for installation companies seeking a proven, commercial-grade inverter with low operating costs.
Ranking
Specifications
Pros and cons
Schneider Electric's official datasheet lists 98.4% peak and 98.0% CEC efficiency for the 25 kVA model (98.0%/97.5% for the 18 kVA model), a result comparable to top-tier commercial inverters of its era and one that minimizes DC/AC conversion losses.
The 250-1000 V MPPT operating range (300-800 V full-power for the 18 kVA model, 500-800 V for the 25 kVA model) with 2 MPPT trackers and 4 strings per MPPT allows flexible string design across varying module configurations and roof orientations.
UL 1741 certification confirms compliance with North American grid-safety standards, easing approval for commercial installations that require rigorous documentation, particularly in the North American market.
A built-in DC disconnect reduces the number of BoS components and installation time, while native Modbus communication enables integration with SCADA and monitoring systems without additional protocol converters.
Per the official datasheet, acoustic emissions stay below 55 dBA, which is advantageous for installations near offices or retail buildings where fan-cooled unit noise can be a concern.
The Conext CL-NA series (released 2015) is formally discontinued by Schneider Electric, as confirmed on the manufacturer's discontinued-products list. This means limited availability of spare parts and warranty service, and new deployments require selecting a replacement product.
Unlike newer tier-1 commercial inverters using convection or fanless cooling, the CL-NA relies on fans, increasing the risk of mechanical component failure and adding long-term maintenance costs.
Schneider has not published a formal end-of-life date or a designated replacement product for the CL-NA, making long-term service planning difficult for commercial installations relying on this series.
Alternatives
About the Conext CL-NA series
These answers cover the whole series. Where a figure differs, the specification above is this model's own.