Skip to main content

Schneider Electric RL 3000 E

3 kW Grid-tie Single-phase
Datasheet PDF
Rated AC (kW)
3.00
Strong · top 21%
Euro eff. (%)
97.0
Typical · median 96.9%
MPPT
2
Strong · top 22%
Max DC (V)
550
Typical · median 550 V
Weight (kg)
20.0
Typical · median 10.8 kg
Warranty (yrs)
5
Typical · median 5 yrs

The Conext RL series comprises single-phase grid-tie inverters from Schneider Electric built for residential installations, available in 3, 4 and 5 kW ratings plus an -S variant with an integrated DC disconnect, eliminating the need for a separate external switch. The standout feature of this family is its dual MPPT tracking, which allows optimal energy management across roofs with differing tilt, orientation, or partial shading - so installers are not forced to compromise by wiring mismatched panels into a single string. The units come with pluggable MC4 connectors on both the DC and AC sides, substantially speeding up installation and field servicing. Another advantage is automatic country and language configuration, simplifying deployment across different regions without manual reprogramming. The series also stands out for its compatibility with the Conext ComBox module, enabling zero export operation - a critical solution for markets lacking feed-in incentive schemes. This makes it a solid choice for installers seeking a reliable, easy-to-configure inverter for single-family homes, where configuration flexibility and reduced installation time matter more than raw peak output alone.

Ranking

449 inverters up to 3 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.0% 96.9% Typical 85
MPPT trackers 2 1 Strong · top 22% 6
Max DC input voltage 550 V 550 V Typical 125
Weight per kW 6.7 5.5 Typical 278
Warranty 5 yrs 5 yrs Typical 29
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 3 kW Continuous output
Max apparent power 3.00 kVA
Phases Single-phase
Nominal AC voltage 230 V 184-276V
Max AC current 13.9 A
Grid frequency 50 Hz Range 50/60 Hz +/- 5 Hz
Power factor 0.8 leading - 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC voltage 550 V Caps the string length
MPPT voltage range 180 to 500 V
Start-up voltage 100 V
MPPT trackers 2
European efficiency 97.0 % Weighted across part loads
Max efficiency 97.5 % Best single operating point
Dimensions 420 × 480 × 160 mm Height × width × depth
Weight 20.0 kg 6.7 kg per kW
Enclosure IP65
Cooling natural
Noise 40 dB
Operating temperature -20 to 65 °C
Max humidity 100 %
Max altitude 2000 m
Interfaces EthernetDisplay
Protocols RS485ModbusEthernet
Protection DC switch
Warranty 5 years Standard manufacturer cover
Certifications CEEN/IEC 62109-1EN/IEC 62109-2AS3100AS5033VDE-AR-N 4105RD1699CEI 0-21UTE C15-712-1AS4777VDE 0126IEC 62116IEC 61727IEC 61683G83/2G59/2C10/C11 ed. 06.2012RoHSREACHIEC 60068-2EN 61000-6-3EN 61000-6-2

Pros and cons

5 positive · 2 caution
What owners get
Dual MPPT tracker

Two MPPT inputs (full-power range 160-500V for the RL3000E and 180-500V for the RL4000E/5000E) allow handling two independent strings with different tilt, orientation, or shading without production loss - a feature that was uncommon in single-phase residential inverters when the series launched in 2013.

High energy conversion efficiency

The manufacturer rated peak efficiency at 97.5% and European efficiency at 97.0% across the entire 3/4/5 kW lineup, figures Schneider Electric marketing materials compared favorably against competitors sitting around 96%.

MC4 plug-in connectors on DC and AC

Plug-in MC4 connectors on both the DC input and AC output significantly reduce installation and field service time compared to solutions requiring on-site cable crimping.

-S variant with built-in DC disconnect

The integrated DC disconnect switch in the -S variant eliminates the need for additional external switchgear, reducing material cost and installation time for contractors.

Zero export mode support

Compatibility with the Conext ComBox module enables zero export operation, a key feature in markets lacking grid feed-in compensation schemes (e.g., some European markets between 2013-2021).

Trade-offs
Discontinued - limited service support

The Conext RL series was discontinued in 2021 after 8 years on the market (launched 2013) and is listed on Schneider Electric's discontinued products page. For installers, this means limited availability of spare parts and technical support, complicating servicing of existing installations.

No support for modern energy storage standards

As a pure grid-tied string inverter, the RL series offers no battery storage integration or backup power functionality, unlike the manufacturer's newer Conext XW Pro line, limiting its appeal for current hybrid PV+battery projects.

Inverter Power Euro eff. MPPT Weight Difference
Schneider Electric RL 3000 E 3 kW 97.0% 2 20.0 kg You are here
SolarEdge SE3000H (HD‑Wave, single phase) 3 kW 98.3% - 7.8 kg +1.3 pp efficiency, 12.2 kg lighter
XG3KTR-S 3 kW 98.3% 2 12.0 kg +1.3 pp efficiency, 8.0 kg lighter
SPI3K-B 3 kW 98.0% 2 18.5 kg +1.0 pp efficiency, 1.5 kg lighter
ASW3K-LT-G2 Pro 3 kW 97.9% 2 16.0 kg +0.9 pp efficiency, 4.0 kg lighter
Solis-3P3K-4G 3 kW 97.8% 2 17.3 kg +0.8 pp efficiency, 2.7 kg lighter
T3-M 3 kW 97.8% 2 16.5 kg +0.8 pp efficiency, 3.5 kg lighter
T3-G3 3 kW 97.8% 2 17.0 kg +0.8 pp efficiency, 3.0 kg lighter
X3-MIC-3K-G2 3 kW 97.8% 2 15.5 kg +0.8 pp efficiency, 4.5 kg lighter

About the Conext RL series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Is the Schneider Electric Conext RL series still available for purchase?
No, the Conext RL series has been discontinued by Schneider Electric and appears on the manufacturer's discontinued products list. Units may still be found in distributor stock, but no new factory orders are being produced. Warranty service and spare parts availability should be confirmed directly with your local Schneider Electric representative, since support for discontinued models can be time-limited.
What is the difference between the Conext RL 3, 4, and 5 kW models and the -S variant?
The main difference is the rated power output (3, 4, or 5 kW) and the DC-side equipment. The -S variant has a built-in DC disconnect, so installers don't need to add an external disconnect switch required by regulations in many countries. Other specs, such as the dual MPPT trackers and MC4 connectors, are identical across all power ratings.
How does dual MPPT work on the Conext RL and when is it needed?
Two independent MPPT trackers let you split the array into two separate strings and optimize each one independently. This is useful when a roof has two sections with different tilt angles, orientation (e.g., east-west), or when part of the array experiences partial shading. Without this feature, the installer would have to wire all panels into a single string, reducing overall system performance under non-uniform conditions.
What warranty comes with the Conext RL inverters?
The standard manufacturer warranty on the Conext RL series is 5 years, with the option to extend coverage to 10 years. The exact extension terms and availability in a given country should be verified with your local Schneider Electric distributor, as warranty terms can vary by region, especially now that the series has been discontinued.
Can the Conext RL operate in zero-export mode without feeding energy to the grid?
Yes, when paired with the Conext ComBox module, Conext RL inverters can run in zero-export mode, limiting output so no energy is fed back into the grid. This is essential in markets without net metering or feed-in incentives, or where the grid operator prohibits export. Without the ComBox, the inverter operates in standard grid-tie mode.
Is the Conext RL faster to install than comparable inverters?
Yes, plug-in MC4 connectors on both the DC and AC sides make installation and field servicing significantly faster, since there's no need to hand-wire terminal connections. Additionally, automatic country and language configuration removes the need for manual reprogramming of grid settings during commissioning, speeding up deployment across different regions.