Skip to main content
Active Ingeteam Clear all Found 22 inverters
Model Rated AC Type Phase Euro eff. MPPT Max DC kg/kW Warranty
350TL M12 346 kW Grid-tie 3-ph 98.6% 12 1500 V 0.4 kg/kW -
330TL M12 330 kW Grid-tie 3-ph 98.6% 12 1500 V 0.5 kg/kW -
300TL 690V 298 kW Grid-tie 3-ph 98.6% 1 1500 V 0.4 kg/kW -
300TL 675V 292 kW Grid-tie 3-ph 98.6% 1 1500 V 0.4 kg/kW -
300TL 660V 285 kW Grid-tie 3-ph 98.6% 1 1500 V 0.4 kg/kW -
300TL 645V 279 kW Grid-tie 3-ph 98.6% 1 1500 V 0.4 kg/kW -
300TL 630V 272 kW Grid-tie 3-ph 98.6% 1 1500 V 0.4 kg/kW -
300TL 615V 266 kW Grid-tie 3-ph 98.6% 1 1500 V 0.4 kg/kW -
300TL 600V 260 kW Grid-tie 3-ph 98.6% 1 1500 V 0.4 kg/kW -
110TL M9 110 kW Grid-tie 3-ph 97.7% 9 1000 V 0.8 kg/kW 5 yr
100TL 100 kW Hybrid 3-ph 98.1% - 1100 V 0.8 kg/kW 5 yr
50TL M4 50 kW Grid-tie 3-ph 97.7% - 1000 V 0.9 kg/kW 5 yr
30TL M3 30 kW Grid-tie 3-ph 97.5% - 1000 V 1.1 kg/kW 5 yr
20TL M2 20 kW Grid-tie 3-ph 97.9% 2 1000 V 1.0 kg/kW 10 yr
15TL M2 15 kW Grid-tie 3-ph 97.6% 2 1000 V 1.3 kg/kW 10 yr
10TL M2 10 kW Grid-tie 3-ph 97.3% 2 1000 V 1.7 kg/kW 10 yr
10TL M 10 kW Hybrid 3-ph 96.7% 2 950 V 3.3 kg/kW 5 yr
6TL M2 6 kW Grid-tie 1-ph 96.4% - - 1.4 kg/kW 10 yr
6TL M 6 kW Hybrid 1-ph 95.2% 2 550 V 4.3 kg/kW 5 yr
4.5TL M 4.5 kW Hybrid 1-ph 95.2% 2 550 V 5.8 kg/kW 5 yr
Reading this table

Rated AC is the continuous output

The nominal AC power from the datasheet, usually the number in the model name. Where only a maximum is published, that is shown instead.

Euro efficiency, not peak

The figure weighted across part loads, which sits below the peak efficiency a datasheet prints first.

kg per kW

Weight divided by rated power, so a 10 kW and a 3 kW unit can be compared for what they cost to mount.

A dash means no data

The manufacturer did not publish it. We never estimate a missing value.