Model Rated AC Type Phase Euro eff. MPPT Max DC kg/kW Warranty
LSP 100K 100 kW Hybrid 1-ph - 12 1100 V 1.2 kg/kW 5 yr
TriP 30K 30 kW Hybrid 3-ph - - 1000 V 1.4 kg/kW 5 yr
TriP 25K 25 kW Hybrid 3-ph - - 1000 V 1.7 kg/kW 5 yr
TriP 20K 20 kW Hybrid 3-ph - - 1000 V 2.1 kg/kW 5 yr
SNA US 15K 15 kW Hybrid 1-ph - 2 480 V 3.2 kg/kW 2 yr
TriP 15K 15 kW Hybrid 3-ph - - 1000 V 2.9 kg/kW 5 yr
GEN2-LB-EU 14K 14 kW Hybrid 1-ph 94.2% 3 550 V 3.4 kg/kW 10 yr
SNA2-EU-LT 14K 14 kW Hybrid 1-ph - 2 500 V 2.3 kg/kW 2 yr
SNA-EU 14K 14 kW Hybrid 1-ph - 2 500 V 3.1 kg/kW 2 yr
GEN-LB-US 13K 13 kW Hybrid 1-ph - 2 550 V 4.2 kg/kW 10 yr
GEN PRO-LB-EU 12K 12 kW Hybrid 1-ph 96.0% 3 530 V 2.5 kg/kW 10 yr
GEN2-LB-EU 12K 12 kW Hybrid 1-ph 94.2% 3 550 V 4.0 kg/kW 10 yr
LXP-LB-US 12K 12 kW Hybrid 1-ph - 3 600 V 4.6 kg/kW 10 yr
SNA2-EU-LT 12K 12 kW Hybrid 1-ph - 2 500 V 2.7 kg/kW 2 yr
SNA-EU 12K 12 kW Hybrid 1-ph - 2 500 V 3.6 kg/kW 2 yr
SNA US 12K 12 kW Hybrid 1-ph - 2 480 V 4.0 kg/kW 2 yr
TriP 12K 12 kW Hybrid 3-ph - - 1000 V 3.2 kg/kW 5 yr
LXP-LB-EU 12K 11.5 kW Hybrid 1-ph 96.0% 3 600 V 4.3 kg/kW 5 yr
GEN-LB-EU 10K 10 kW Hybrid 1-ph 94.3% 2 600 V 4.3 kg/kW 5 yr
GEN-LB-US 10K 10 kW Hybrid 1-ph - 2 550 V 5.5 kg/kW 10 yr
Reading this table

Rated AC is the continuous output

The nominal AC power from the datasheet, usually the number in the model name. Where only a maximum is published, that is shown instead.

Euro efficiency, not peak

The figure weighted across part loads, which sits below the peak efficiency a datasheet prints first.

kg per kW

Weight divided by rated power, so a 10 kW and a 3 kW unit can be compared for what they cost to mount.

A dash means no data

The manufacturer did not publish it. We never estimate a missing value.