Skip to main content

HY-DH132N10-730

730 Wp N-type Bifacial 80%
ComparePV verdict

Efficiency leader, no clear weak spot

Rank 322 of 14,005
Compare panels Datasheet PDF
Power (Wp)
730
Strong · top 5%
Efficiency (%)
23.50
Strong · top 5%
Density (Wp/m²)
235.0
Strong · top 5%
Temp (%/°C)
-0.290
Typical · median -0.290
Weight (kg)
38.5
Typical · median 38.0 kg
Warranty (yrs)
30
Typical · median 30 yrs

The HY-DH132N10 Plus series is Runergy's answer for installations that demand maximum energy efficiency on limited roof or ground area. The modules are built on N-Type TOPCon technology combined with the G12 wafer platform, delivering stable performance even at elevated module temperatures typical of Polish summers. The use of half-cut cells reduces resistive losses and improves resistance to microcracks and partial shading, which matters for irregular roof layouts. The dual-glass, bifacial construction captures light reflected off the ground, boosting energy yield without increasing the footprint of the installation - an attractive solution for ground-mount farms and installations over light-colored surfaces. Thanks to the characteristics of N-Type cells, the module stands out with low annual power degradation and resistance to LID and LeTID effects, translating into predictable energy output throughout its service life. The series suits both residential prosumer setups and commercial PV farm projects, where long-term reliability and a low levelized cost of energy per installed watt matter most. It's a solution for investors seeking a balance between high performance and long-term durability.

Ranking

90 panels in the segment N-type 700-750 W
Metric This panel Median Position in segment Overall rank
Module efficiency 23.50% 22.88% Strong · top 5% 716
Power density 235.0 228.6 Strong · top 5% 800
Temperature coefficient -0.290 -0.290 Typical 2,165
Weight per kWp 52.7 53.5 Typical 6,396
Performance warranty 30 yrs 30 yrs Typical 21
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Signals from the data

2 positive · 0 caution
Best for

Commercial, utility-scale and shaded-installations.

Strengths
23.50% module efficiency

Top 5% of the N-type 700-750 W segment, against a median of 22.88%. Ranked 716th in the whole database.

235.0 watts per square metre

Top 5% of the N-type 700-750 W segment, against a median of 228.6. Ranked 800th in the whole database.

Notes from the database
  • 23.5% module efficiency - 0.6pp better than the N-type 700-750W median of 22.9%
  • At 235.0 W/m² power density, this panel generates 6.4 W/m² more per unit area than N-type 700-750W median (228.6 W/m²)
  • At -0.29%/°C, hot weather performance is typical for N-type 700-750W panels
  • Bifaciality factor of 80% can add 4-12% extra yield with reflective mounting surface
  • In the top 5% for efficiency among all N-type panels

Specifications

Open datasheet PDF
Nominal power (Pmax) 730 Wp Nameplate at 1000 W/m², 25 °C
Module efficiency 23.50 % Strong Segment median 22.88%
Vmpp · Impp 41.67 V · 17.52 A Operating point at max power
Voc · Isc 49.77 V · 18.59 A Sizes the string length
Max system voltage 1500 V Longer strings than 1000 V modules
Dimensions 2384×1303×35 mm · 3.11 m² of roof
Weight 38.5 kg Typical Typical · median 38.0 kg
Cells 132 · N-type Monocrystalline
Bifaciality 80 % Rear output as a share of front
Coefficient Pmax -0.290 %/°C Typical median -0.290 of its segment
Coefficient Voc · Isc -0.250 · 0.045 %/°C
NOCT 42 °C At 800 W/m², 20 °C ambient
Product warranty 12 years Hardware defects only
Performance warranty 30 years Typical median 30 yrs · median 30 yrs
End-of-warranty output 87.4 % Equals 638 W guaranteed
Degradation 1.00 → 0.40 % First year, then annual

Simulations

Live - change any input
Lifetime output & value
30 years at 1200 kWh/kWp/year and €0.50 per kWh
Power in year 30
-
Lifetime energy
-
Energy value
-
With bifacial gain
-

Degradation from this panel's own datasheet figures. No inverter, soiling or shading losses.

Heat losses
-0.290 %/°C against a segment median of -0.290
-
Bifacial gain
Rear gain over light concrete: -
-

Model: bifaciality × albedo × 0.6 view factor. A first-order estimate, not a yield simulation.

Filter these
Size
Panel Power Eff. Temp. Weight Difference
Runergy HY-DH132N10-730 730 W 23.50% -0.290 38.5 kg You are here
AIKO-A680-MDE72Mw 680 W 25.20% -0.260 29.0 kg -50 W, lighter, +1.7 pp
AIKO-A700-MAE78Dw 700 W 25.00% -0.260 34.5 kg -30 W, lighter, +1.5 pp
AIKO-A695-MAE78Dw 695 W 24.90% -0.260 34.5 kg -35 W, lighter, +1.4 pp
AIKO-A690-MAE78Dw 690 W 24.70% -0.260 34.5 kg -40 W, lighter, +1.2 pp
AIKO-A685-MAE78Dw 685 W 24.50% -0.260 34.5 kg -45 W, lighter, +1.0 pp
TSM-NEG21C.20Q-760 760 W 24.50% -0.260 38.3 kg +30 W, cooler, +1.0 pp
AIKO-A680-MAH78Dw 680 W 24.30% -0.260 34.7 kg -50 W, lighter, +0.8 pp
GK-4-78HGBD-780M 780 W 24.30% -0.260 38.7 kg +50 W, cooler, +0.8 pp
AIKO-A780-GRH78Dw 780 W 24.30% -0.260 39.8 kg +50 W, cooler, +0.8 pp
SS9-66HD-645M 645 W 20.76% -0.330 37.5 kg -85 W, hotter, -2.7 pp
SS9-66HD-650M 650 W 20.92% -0.330 37.5 kg -80 W, hotter, -2.6 pp
SS9-66HS-655M 655 W 21.09% -0.340 32.5 kg -75 W, lighter, -2.4 pp
SS9-66HD-660M 660 W 21.25% -0.330 37.5 kg -70 W, hotter, -2.2 pp
SS9-66HD-665M 665 W 21.41% -0.330 37.5 kg -65 W, hotter, -2.1 pp
SS9-66HS-670M 670 W 21.57% -0.340 32.5 kg -60 W, lighter, -1.9 pp
AIKO-A805-GRH78Dw 805 W 25.10% -0.260 39.8 kg +75 W, cooler, +1.6 pp

Found 1390 panels of the same or similar size to this one, within ±10 mm. See them here Found 1400 panels of the same or similar size to this one, within ±25 mm. See them here Found 1400 panels of the same or similar size to this one, within ±50 mm. See them here Found 1432 panels of the same or similar size to this one, within ±100 mm. See them here

Common questions

6 answered
How does N-type TOPCon technology in the Runergy HY-DH132N10 Plus differ from standard PERC panels?
N-type TOPCon cells feature an additional passivation layer that reduces carrier recombination and increases energy conversion efficiency compared to PERC cells. This results in higher power output (up to 730 Wp) and better performance at elevated temperatures, which matters during summer when module temperatures can exceed 60°C on a roof.
Is it worth installing bifacial Runergy HY-DH132N10 Plus panels on a light-colored roof?
Yes, the dual-glass bifacial construction captures light reflected from the surface below, so light, reflective surfaces such as white gravel, roofing membrane, or light concrete boost energy yield further, often by several percent compared to a monofacial module. On darker roofs the effect is smaller, but the panel still performs normally on the front side.
What warranty comes with Runergy HY-DH132N10 Plus panels?
The manufacturer provides a 12-year product warranty and a 30-year linear power output warranty. Thanks to the characteristics of N-type cells, annual power degradation is low, and the module maintains high energy yield throughout most of its service life, resulting in a predictable return on investment.
Are half-cut cells in the HY-DH132N10 Plus series more resistant to shading and microcracks?
Yes, splitting cells in half reduces resistive losses and means partial shading, from a chimney or antenna for example, causes a smaller drop in total panel output. The half-cut design also increases mechanical resistance to microcracks during transport and installation, which matters on uneven roof surfaces.
Is Runergy a reliable solar panel manufacturer?
Runergy is a China-based manufacturer holding Tier 1 status, meaning it appears on the list of reputable PV module suppliers backed by financial stability and production scale. Tier 1 status also makes it easier to secure financing and insurance for the installation, since banks and insurers treat such manufacturers as lower risk.
Is the Runergy HY-DH132N10 Plus series better suited for residential or commercial installations?
The series works well for both residential rooftop installations and large commercial or ground-mount solar farm projects. The high power output per panel (730 Wp) reduces the number of modules needed to reach a target system capacity, lowering costs for mounting structures and labor on larger projects.
Add to compare