Skip to main content

Inverter database

Grid-tie, hybrid, off-grid and microinverters, with every figure taken from the manufacturer's datasheet. Panel database

Manufacturer 14 with data
Found 1,399 inverters
Model Rated AC Type Phase Euro eff. MPPT Max DC kg/kW Warranty
Sofar Solar SOFAR 5KTLM-G3 5 kW Grid-tie 1-ph - 2 600 V - -
Sofar Solar SOFAR 5.5KTLX-G3 5 kW Grid-tie 3-ph 97.5% 2 1100 V 3.4 kg/kW -
Sofar Solar HYD 5000-EP 5 kW Hybrid 1-ph 94.6% 1 600 V 4.3 kg/kW -
Sofar Solar SOFAR 5KTLM-G3-A 5 kW Grid-tie 1-ph - 2 600 V - -
Sofar Solar ESI-5K-T1 5 kW Hybrid 3-ph 97.0% 3 1000 V 6.0 kg/kW -
Sungrow SG5.0RT-P2 5 kW Grid-tie 3-ph 97.2% 2 1100 V 3.6 kg/kW -
Sungrow SG5.0RS 5 kW Grid-tie 1-ph 97.3% 2 600 V 2.0 kg/kW -
Sungrow MG5RL 5 kW Hybrid 1-ph 96.7% 2 500 V 3.6 kg/kW -
Sungrow SH5.0RS 5 kW Hybrid 1-ph 97.3% 2 600 V 3.7 kg/kW -
SMA Solar SB5.0-1AV-41 (Sunny Boy 5.0) 5 kW Grid-tie 1-ph 96.5% 2 600 V 3.5 kg/kW 5 yr
SMA Solar STP5.0-3AV-40 (Sunny Tripower 5.0) 5 kW Grid-tie 3-ph 97.4% 2 850 V 3.4 kg/kW 5 yr
SMA Solar STP5.0-3SE-40 5 kW Hybrid 3-ph 97.3% 2 1000 V 6.0 kg/kW 5 yr
SMA Solar SBS5.0-10 (Sunny Boy Storage 5.0) 5 kW Hybrid 1-ph - 3 600 V 5.2 kg/kW 5 yr
Fronius International Fronius Symo GEN24 / GEN24 Plus 5.0 5 kW Hybrid 3-ph 97.5% 2 1000 V 3.1 kg/kW -
Fronius International Fronius Primo 5.0-1 5 kW Grid-tie 1-ph - 2 1000 V 4.3 kg/kW 10 yr
Fronius International Fronius Primo GEN24 5.0 208-240 [Plus] 5 kW Hybrid 1-ph - 2 600 V 3.0 kg/kW -
Fronius International Fronius Primo GEN24 5.0 5 kW Hybrid 1-ph 97.2% 2 600 V 3.1 kg/kW -
Fronius International Fronius Primo GEN24 5.0 Plus 5 kW Hybrid 1-ph 97.2% 2 600 V 3.1 kg/kW -
GoodWe GW5k-ET 5 kW Hybrid 3-ph 97.2% 2 1000 V 4.8 kg/kW -
GoodWe GW5KN-ET 5 kW Hybrid 3-ph - 2 1000 V 4.8 kg/kW -
Reading this table

Rated AC is the continuous output

The nominal AC power from the datasheet, usually the number in the model name. Where only a maximum is published, that is shown instead.

Euro efficiency, not peak

The figure weighted across part loads, which sits below the peak efficiency a datasheet prints first.

kg per kW

Weight divided by rated power, so a 10 kW and a 3 kW unit can be compared for what they cost to mount.

A dash means no data

The manufacturer did not publish it. We never estimate a missing value.