Skip to main content

Solectria PVI-25TL-480

25 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
25.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
2
Typical · median 2
Max DC (V)
1000
Typical · median 1000 V
Weight (kg)
22.0
Strong · 16.0 kg below median
Warranty (yrs)
10
Strong · top 18%

The PVI-TL-480 series comprises transformerless three-phase inverters built for commercial and industrial PV projects, from rooftops to carports and ground-mount arrays. The defining advantage of this family is its transformerless design, which reduces unit weight and footprint while improving overall conversion efficiency. Each model features two independent MPPT trackers paired with a flexible wiring box, giving system designers the freedom to configure strings to match irregular roof layouts or partially shaded array sections. The inverters are compatible with bifacial PV modules, making them suitable for both conventional PERC projects and newer designs that capture reflected light from the ground. Safety is reinforced by integrated arc-fault protection and a built-in SunSpec-compliant transmitter that enables module-level rapid shutdown in line with NEC requirements. The entire unit is housed in a NEMA 4X enclosure rated for harsh outdoor conditions, helping to minimize service downtime. An adjustable mounting angle from 15 to 90 degrees, along with remote diagnostics and firmware updates, makes the PVI-TL-480 series a compelling choice for installers seeking flexibility, durability, and low operating costs on commercial-scale projects.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.0% Not published -
MPPT trackers 2 2 Typical 168
Max DC input voltage 1000 V 1000 V Typical 229
Weight per kW 0.9 1.8 Strong · top 6% 37
Warranty 10 yrs 5 yrs Strong · top 18% 8
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 25 kW Continuous output
Max apparent power 25.00 kVA
Phases Three-phase
Nominal AC voltage 480 V -12% to +10%
Max AC current 30.5 A
Grid frequency 60 Hz Range 57-63Hz
Power factor 0.8 leading to 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 37.50 kW DC/AC ratio 1.50
Max DC voltage 1000 V Caps the string length
MPPT voltage range 560 to 850 V
Start-up voltage 330 V
MPPT trackers 2 3 strings each
Max input current per MPPT 45.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 36.0 A Must exceed the panel's Isc
Max efficiency 98.5 % Best single operating point
CEC efficiency 98.0 % California Energy Commission weighting
Dimensions 405 × 400 × 200 mm Height × width × depth
Weight 22.0 kg 0.9 kg per kW
Enclosure NEMA 4X
Noise 60 dB
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces EthernetBluetoothDisplay
Protocols ModbusSunSpecEthernetBluetooth
Protection AFCIDC switchSurge protection
Warranty 10 years Standard manufacturer cover
Certifications IEEE 1547-2018UL 1741-SBUL1741-SAUL1699BUL1998CSA-C22.2 NO.107.1-01FCC Part 15 (Subpart B, Class A)

Pros and cons

5 positive · 2 caution
What owners get
Transformerless design

The absence of a transformer reduces unit weight and footprint while limiting conversion losses relative to classic transformer-based inverters, delivering higher weighted (European/CEC) efficiency and easier transport and mounting on roofs with limited load capacity.

Dual independent MPPT trackers

A flexible wiring box with two independent MPPT trackers lets designers freely configure strings for orientation, shading, or irregular roof geometry - a key advantage for carports and multi-plane commercial installations.

Bifacial module compatibility

Support for bifacial modules allows the same inverter platform to serve both classic PERC projects and newer installations capturing albedo-reflected light, without swapping conversion hardware.

Integrated AFCI and SunSpec rapid shutdown

A built-in SunSpec-compliant transmitter enables module-level rapid shutdown per NEC 690.12, while integrated arc-fault detection reduces fire risk without requiring separate module-level power electronics.

NEMA 4X enclosure

NEMA 4X ingress protection allows installation in harsh outdoor conditions (moisture, dust, corrosion) without added enclosures, reducing service downtime in industrial and ground-mount installations.

Trade-offs
1000V DC architecture, not 1500V

The series is built on a 1000V DC bus, while since roughly 2018-2020 the commercial and utility segment has shifted to 1500V architecture (including this manufacturer's own XGI 1500 line), enabling longer strings and lower BoS cost per kWp. This limits PVI-TL-480's competitiveness in new large-scale projects.

2013-era product generation

The platform launched in 2013, making it older than current tier-1 string inverter designs (e.g., SMA Sunny Highpower Peak3, Huawei SUN2000), which in practice means lower power-to-weight density and less developed remote analytics compared to today's segment leaders.

Inverter Power Euro eff. MPPT Weight Difference
Solectria PVI-25TL-480 25 kW - 2 22.0 kg You are here
MID 25KTL3-X2 (Pro.E) 25 kW 98.6% 3 24.0 kg +1 MPPT, 2.0 kg heavier
MID 25KTL3-X 25 kW 98.6% 2 23.0 kg 1.0 kg heavier
MID 25KTL3-X1 25 kW 98.5% - 29.5 kg 7.5 kg heavier
PRO25T-S3 25 kW 98.5% 2 20.0 kg 2.0 kg lighter
HYX-S25K-LT 25 kW 98.5% - 44.0 kg 22.0 kg heavier
GW25K-MT 25 kW 98.4% - 40.0 kg 18.0 kg heavier
Fronius Verto 25.0 400 25 kW 98.3% 4 35.2 kg +2 MPPT, 13.2 kg heavier
BNT025KTL 25 kW 98.3% 2 19.0 kg 3.0 kg lighter

About the PVI-TL-480 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the maximum power output of the Solectria PVI-TL-480 inverter series?
The PVI-TL-480 series consists of three-phase transformerless inverters rated up to 480 kVA, designed for large commercial and industrial installations. The transformerless design delivers high conversion efficiency while keeping the unit lightweight and compact, simplifying transport and installation on rooftops, carports, and ground-mount systems.
Are PVI-TL-480 inverters compatible with bifacial solar modules?
Yes, the PVI-TL-480 series is fully compatible with bifacial modules. This means the inverters can be used in both traditional PERC-based projects and newer installations that rely on reflected light from the ground surface, increasing design flexibility and potential energy yield, especially for ground-mount and carport systems.
What are the two MPPT trackers on the PVI-TL-480 inverter used for?
Two independent MPPT trackers with a flexible connection box allow designers to split module strings into two separate groups, matched to different tilt angles, orientations, or shading conditions. This is especially useful on irregular rooftops or installations where part of the array is partially shaded by chimneys, HVAC units, or neighboring structures.
Can the PVI-TL-480's NEMA 4X enclosure handle outdoor installation in harsh conditions?
Yes, PVI-TL-480 inverters are housed in a NEMA 4X enclosure resistant to dust, rain, corrosion, and demanding weather conditions, allowing outdoor mounting without additional protective housing. This construction minimizes the need for frequent maintenance checks and improves long-term reliability of the unit in the field.
How does arc-fault protection and rapid shutdown work on this series?
PVI-TL-480 inverters feature integrated arc-fault protection that detects dangerous discharges in the DC circuits and automatically shuts down the system. A built-in SunSpec-compliant transmitter also enables module-level rapid shutdown, a requirement under U.S. NEC codes, improving safety for service crews and firefighters.
Can the PVI-TL-480 be mounted at different roof angles?
Yes, the PVI-TL-480 series supports an adjustable mounting angle from 15 to 90 degrees, allowing installation on flat roofs, pitched roofs, carport structures, and ground-mount systems. Remote diagnostics and firmware updates also let technicians monitor performance and apply fixes without needing to be physically on site.