Skip to main content
Active SAJ Clear all Found 138 inverters
Model Rated AC Type Phase Euro eff. MPPT Max DC kg/kW Warranty
H2-15K-T3 15 kW Hybrid 3-ph 97.6% 3 1000 V 3.3 kg/kW 5 yr
H2-15K-LT2 15 kW Hybrid 3-ph 97.5% 2 1000 V 3.5 kg/kW -
H2-14K-LT2 14 kW Hybrid 3-ph 97.5% 2 1000 V 3.8 kg/kW -
HS3-12K-T2-W/G-PX 12 kW Hybrid 3-ph 97.6% 2 1000 V 2.8 kg/kW -
R6-12K-T2 12 kW Grid-tie - - - - - -
H2-12K-S4-US 12 kW Hybrid 1-ph - - 600 V 2.7 kg/kW 10 yr
H2-12K-T3 12 kW Hybrid 3-ph 97.6% 3 1000 V 4.2 kg/kW 5 yr
H2-12K-LS2 12 kW Hybrid 1-ph 97.0% 2 500 V 2.9 kg/kW -
H2-12K-LT2-LV 12 kW Hybrid 3-ph 97.5% 2 1000 V 4.4 kg/kW -
H2-12K-LT2 12 kW Hybrid 3-ph 97.5% 2 1000 V 4.4 kg/kW -
H2-11.4K-LS4-US 11.4 kW Hybrid 1-ph - - 600 V 4.2 kg/kW 10 yr
HS3-10K-T2-W/G-PX 10 kW Hybrid 3-ph 97.6% 2 1000 V 3.4 kg/kW -
R6-10K-S2-X 10 kW Grid-tie - - - - - -
R6-10K-S3 10 kW Grid-tie - - - - - -
R6-10K-T2 10 kW Grid-tie - - - - - -
H2-10K-T2 10 kW Hybrid 3-ph 97.6% 2 1000 V 2.5 kg/kW 5 yr
H2-10K-T2-B 10 kW Hybrid 3-ph 97.6% 2 1000 V 2.5 kg/kW 5 yr
H2-10K-S3 10 kW Hybrid 1-ph 97.0% 3 600 V 2.6 kg/kW -
H2-10K-S4-US 10 kW Hybrid 1-ph - - 600 V 3.2 kg/kW 10 yr
H2-10K-T3 10 kW Hybrid 3-ph 97.6% 3 1000 V 5.0 kg/kW 5 yr
Reading this table

Rated AC is the continuous output

The nominal AC power from the datasheet, usually the number in the model name. Where only a maximum is published, that is shown instead.

Euro efficiency, not peak

The figure weighted across part loads, which sits below the peak efficiency a datasheet prints first.

kg per kW

Weight divided by rated power, so a 10 kW and a 3 kW unit can be compared for what they cost to mount.

A dash means no data

The manufacturer did not publish it. We never estimate a missing value.