Skip to main content
SAJ H2-15K-T3

SAJ H2-15K-T3

15 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
15.00
Weak · bottom 17%
Euro eff. (%)
97.6
Typical · median 98.0%
MPPT
3
Strong · top 25%
Max DC (V)
1000
Typical · median 1000 V
Weight (kg)
50.0
Weak · 12.0 kg above median
Warranty (yrs)
5
Typical · median 5 yrs

The SAJ H2 series comprises three-phase hybrid inverters designed for installations that combine solar generation with energy storage, meeting the real-world needs of homeowners and small businesses who want to boost self-consumption and reduce grid dependency. The series stands out thanks to its multiple MPPT inputs, allowing flexible string configuration even with irregular shading or varied roof orientations, which minimizes the energy losses typical of simpler setups. A key advantage is the UPS backup power function with an extremely fast switchover time, making grid outages virtually unnoticeable to the end user. These inverters support high DC oversizing relative to their rated output, enabling installers to fit more panels and get better year-round utilization of the inverter, even during periods of weaker irradiance. The series also incorporates an AFCI arc-fault protection system, improving fire safety throughout the installation. The H2 line is compatible with popular high-voltage battery storage systems, simplifying integration with existing infrastructure and easing service work. It's a solid choice for installers looking for a reliable, scalable three-phase inverter suited equally well to single-family homes and larger commercial projects.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.6% 98.0% Typical 320
MPPT trackers 3 2 Strong · top 25% 58
Max DC input voltage 1000 V 1000 V Typical 229
Weight per kW 3.3 1.8 Weak · bottom 11% 536
Warranty 5 yrs 5 yrs Typical 81
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 15 kW Continuous output
Max apparent power 16.50 kVA
Phases Three-phase
Nominal AC voltage 400 V 180~280/312~485
Max AC current 24.0 A
Grid frequency 50 Hz Range 45~55,55~65
Power factor 0.8 leading~0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 30.00 kW DC/AC ratio 2.00
Max DC voltage 1000 V Caps the string length
MPPT voltage range 180 to 900 V
Start-up voltage 180 V
MPPT trackers 3 2 strings each
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
European efficiency 97.6 % Weighted across part loads
Max efficiency 98.0 % Best single operating point
Battery port Yes
Battery voltage 180~800
Max charge current 50.0 A
Max discharge current 50.0 A
Dimensions 576 × 659 × 242 mm Height × width × depth
Weight 50.0 kg 3.3 kg per kW
Enclosure IP65
Cooling forced-air
Noise 50 dB
Operating temperature -40 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetDisplay
Protocols Wi-FiEthernet4G
Protection AFCISurge protection
Warranty 5 years Standard manufacturer cover
Certifications EN 62109-1/2EN 61000-6-2/4EN 50438EN 50549C10/11IEC 62116IEC 61727RD 1699RD 413UNE 206006UNE 206007NTSCEI 0-16CEI 0-21AS 4777.2NBR 16149NBR 16150VDE-AR-N 4105VDE 0126-1-1

Pros and cons

5 positive · 2 caution
What owners get
Extensive MPPT configuration

Depending on power rating, H2 series models feature 2-3 MPPT inputs (e.g., H2-5/10K with 2 MPPTs, H2-20/30K-T3 with 3 trackers of 2 strings each), allowing flexible combination of panels with different orientation and tilt, reducing energy losses typical of single-MPPT inverters.

Instant UPS switchover

The backup power (UPS) function enables a near-seamless transition to off-grid operation during a grid outage, which is critical for households and businesses sensitive to power interruptions, such as those running refrigeration or medical equipment.

High DC/AC oversizing ratio

The H2 series allows significant oversizing of panel power relative to the inverter's rated output, enabling installation of more modules and better year-round utilization of the unit, especially during low-irradiance periods, boosting annual energy yield.

AFCI fire protection

Built-in arc fault circuit interrupter (AFCI) protection increases DC-side safety, a notable differentiator versus budget inverters lacking this feature, particularly relevant for larger commercial installations.

HV battery storage compatibility

H2 inverters are compatible with popular high-voltage energy storage systems (e.g., Pylontech), simplifying system integration and servicing, as installers can rely on widely available, standardized battery packs.

Trade-offs
No LV battery support

The H2 series is designed exclusively for high-voltage (HV) battery storage and does not support low-voltage batteries, limiting retrofit options for customers who already own an LV storage system from another manufacturer.

MPPT count varies by model size

Smaller variants (e.g., H2-5/10K) have only 2 MPPT inputs, while some comparable 10 kW competitor models offer 3-4 MPPTs, which can limit configuration flexibility on multi-plane roofs at lower power ratings.

Alternatives

All SAJ inverters
Inverter Power Euro eff. MPPT Weight Difference
SAJ H2-15K-T3 15 kW 97.6% 3 50.0 kg You are here
SigenStor Neo EC 15.0 TP 15 kW 98.7% - 30.0 kg +1.1 pp efficiency, 20.0 kg lighter
MID 15KTL3-XH 15 kW 98.5% - 31.0 kg +0.9 pp efficiency, 19.0 kg lighter
HYX-H15K-HT 15 kW 98.2% 2 45.0 kg +0.6 pp efficiency, -1 MPPT, 5.0 kg lighter
HYX-H15K-HSA2 15 kW 98.2% - 38.0 kg +0.6 pp efficiency, 12.0 kg lighter
MOD 15KTL3-HU 15 kW 98.1% 3 20.0 kg +0.5 pp efficiency, 30.0 kg lighter
SUN2000-15K-MB0 15 kW 98.0% 2 21.0 kg +0.4 pp efficiency, -1 MPPT, 29.0 kg lighter
HIT-15L-G3/HIT-15L-G3S 15 kW 98.0% - 41.0 kg +0.4 pp efficiency, 9.0 kg lighter
AF15K-THA 15 kW 98.0% 2 36.0 kg +0.4 pp efficiency, -1 MPPT, 14.0 kg lighter

About the H2 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How many MPPT inputs does the SAJ H2 inverter have, and does it matter for unusual panel layouts?
SAJ H2 series inverters typically feature 2-3 MPPT inputs, depending on the model's power rating. This allows the panel strings to be split independently, for example one string on an east-facing roof section and another facing west, or a separately managed string on an area shaded by a chimney or tree. This reduces energy losses that would otherwise occur with a single shared MPPT and makes better use of irregularly shaped roofs.
How fast does the SAJ H2 inverter switch to backup (UPS) power during a blackout?
Three-phase T2 models in the H2 family switch to battery backup in under 10 milliseconds, meaning household electronics, refrigerators, or Wi-Fi routers won't notice the interruption in practice. Larger T3 units (15-30 kW) have a slightly longer switchover time, but it is still measured in milliseconds, fast enough to avoid any noticeable flicker or outage.
Can the SAJ H2 inverter support more solar panels than its rated power suggests?
Yes, the H2 series supports high DC oversizing relative to the inverter's nominal power, up to 150-200% depending on the model and variant. In practice this means a 10 kW inverter can be paired with more panels than its rating implies, boosting energy yield on cloudy days, in winter, or with a suboptimal roof angle, while the inverter simply caps output during peak sunlight.
What energy storage systems is the SAJ H2 inverter compatible with?
H2 inverters are designed for high-voltage (HV) battery storage systems, enabling straightforward integration with popular HV battery brands without extra converters. This architecture simplifies servicing and future battery expansion, since installers don't need to source nonstandard adapters or worry about compatibility limitations.
What is the AFCI feature on SAJ H2 inverters, and does it genuinely improve safety?
AFCI is an arc-fault detection system for the DC wiring of a solar installation, designed to catch dangerous electrical arcing that can occur from a damaged connector or frayed cable. The inverter continuously monitors the current signature and automatically disconnects the panels if an anomaly is detected, significantly reducing fire risk on the roof, especially in older or expanded systems.
Are SAJ H2 inverters suitable for a small business, or are they only for single-family homes?
The H2 series spans three-phase models from roughly 3 kW up to 30 kW, so it can serve everything from a small single-family home to a larger commercial installation for a small business or farm. The scalable power range and expandable HV battery compatibility mean one manufacturer and product family can cover different growth stages of an installation, simplifying service and parts availability.