Skip to main content
Active Growatt Clear all Found 312 inverters
Model Rated AC Type Phase Euro eff. MPPT Max DC kg/kW Warranty
MID 22KTL3-X 22 kW Grid-tie 3-ph 98.6% 2 1100 V 1.0 kg/kW 5 yr
MID 20KTL3-X2 20 kW Grid-tie 3-ph - 2 1100 V 1.1 kg/kW 5 yr
MID 20KTL3-XH 20 kW Hybrid 3-ph 98.5% - 1100 V 1.6 kg/kW 5 yr
WIT 20K-XHU 20 kW Hybrid 3-ph 97.2% 2 1000 V 2.2 kg/kW -
WIT 20K-HU 20 kW Hybrid 3-ph 97.0% 2 1000 V 2.8 kg/kW -
MID 20KTL3-X 20 kW Grid-tie 3-ph 98.6% 2 1100 V 1.1 kg/kW 5 yr
SPF 18000T DVM-MPV 18 kW Off-grid - - - 250 V 5.8 kg/kW -
WIT 18K-HU 18 kW Hybrid 3-ph 97.0% 2 1000 V 3.1 kg/kW -
MID 17KTL3-XH 17 kW Hybrid 3-ph 98.5% - 1100 V 1.8 kg/kW 5 yr
WIT 17K-XHU 17 kW Hybrid 3-ph 97.2% 2 1000 V 2.6 kg/kW -
WIT 17K-HU 17 kW Hybrid 3-ph 97.0% 2 1000 V 3.2 kg/kW -
MID 17KTL3-X 17 kW Grid-tie 3-ph 98.6% 2 1100 V 1.4 kg/kW 5 yr
MOD 15KTL3-X 15 kW Grid-tie 3-ph 98.2% 2 1100 V 1.1 kg/kW 5 yr
MID 15KTL3-XH 15 kW Hybrid 3-ph 98.5% - 1100 V 2.1 kg/kW 5 yr
WIT 15K-XHU 15 kW Hybrid 3-ph 97.2% 2 1000 V 3.0 kg/kW -
MOD 15KTL3-X2(Pro) 15 kW Grid-tie 3-ph 98.2% 2 1100 V 1.0 kg/kW 8 yr
MOD 15KTL3-HU 15 kW Hybrid 3-ph 98.1% 3 1000 V 1.3 kg/kW 10 yr
MID 15KTL3-X 15 kW Grid-tie 3-ph 98.6% 2 1100 V 1.5 kg/kW 5 yr
WIT 15K-HU 15 kW Hybrid 3-ph 97.0% - 1000 V 2.5 kg/kW 5 yr
MOD 13KTL3-X 13 kW Grid-tie 3-ph 98.2% 2 1100 V 1.2 kg/kW 5 yr
Reading this table

Rated AC is the continuous output

The nominal AC power from the datasheet, usually the number in the model name. Where only a maximum is published, that is shown instead.

Euro efficiency, not peak

The figure weighted across part loads, which sits below the peak efficiency a datasheet prints first.

kg per kW

Weight divided by rated power, so a 10 kW and a 3 kW unit can be compared for what they cost to mount.

A dash means no data

The manufacturer did not publish it. We never estimate a missing value.