Skip to main content
Active GoodWe Clear all Found 145 inverters
Model Rated AC Type Phase Euro eff. MPPT Max DC kg/kW Warranty
GW4K-DT 4 kW Grid-tie 3-ph 97.6% 2 1000 V 3.8 kg/kW -
GW4000-DT 4 kW Grid-tie 3-ph 97.5% 2 1000 V 6.0 kg/kW -
GW3648-EM 3.68 kW Hybrid 1-ph 97.0% - 550 V 4.6 kg/kW -
GW3600-ES-20 (ES G2 series) 3.68 kW Hybrid 1-ph - 2 600 V 5.7 kg/kW -
GW3600M-ES-20 (ES G2 series) 3.68 kW Hybrid 1-ph - 2 600 V 5.4 kg/kW -
GW3600-BH 3.6 kW Hybrid 1-ph 96.0% - - 4.3 kg/kW -
GW3600N-EH 3.6 kW Hybrid 1-ph 97.0% 2 580 V 4.7 kg/kW -
GW3600-ES-C10 3.6 kW Hybrid 1-ph - - 600 V 4.3 kg/kW -
GW3048-EM 3 kW Hybrid 1-ph 97.0% - 550 V 5.3 kg/kW -
GW3000-XS-30 3 kW Grid-tie 1-ph 96.9% 1 600 V 1.5 kg/kW -
GW3k-BH 3 kW Hybrid 1-ph 96.0% - - 5.2 kg/kW -
GW3000-SS 3 kW Grid-tie 1-ph 97.4% 1 500 V 4.0 kg/kW 5 yr
GW3000-ES-20 (ES G2 series) 3 kW Hybrid 1-ph - 2 600 V 6.5 kg/kW -
GW3000-ES-C10 3 kW Hybrid 1-ph - - 600 V 4.8 kg/kW -
GW3000-XS 3 kW Grid-tie 1-ph 97.2% 1 500 V 1.9 kg/kW -
GW2500-XS 2.5 kW Grid-tie 1-ph 97.2% 1 500 V 2.3 kg/kW -
GW2000-MIS 2 kW Microinverter 1-ph - 4 65 V 2.6 kg/kW -
GW2000-SS 2 kW Grid-tie 1-ph 97.4% 1 500 V 6.0 kg/kW 5 yr
GW2000-XS 2 kW Grid-tie 1-ph 97.0% 1 500 V 2.9 kg/kW -
GW1800-MIS 1.8 kW Microinverter 1-ph - 4 65 V 2.9 kg/kW -
Reading this table

Rated AC is the continuous output

The nominal AC power from the datasheet, usually the number in the model name. Where only a maximum is published, that is shown instead.

Euro efficiency, not peak

The figure weighted across part loads, which sits below the peak efficiency a datasheet prints first.

kg per kW

Weight divided by rated power, so a 10 kW and a 3 kW unit can be compared for what they cost to mount.

A dash means no data

The manufacturer did not publish it. We never estimate a missing value.