Skip to main content

SS9-60HD-610M

610 Wp PERC Bifacial 70%
ComparePV verdict

Strong in heat, no clear weak spot

Rank 4,555 of 14,005
Compare panels Datasheet PDF
Power (Wp)
610
Typical for its class
Efficiency (%)
21.55
Strong · top 25%
Density (Wp/m²)
215.5
Strong · top 22%
Temp (%/°C)
-0.330
Strong · top 6%
Weight (kg)
34.5
Typical · median 34.0 kg
Warranty (yrs)
30
Typical · median 30 yrs

The Runergy SS9-60HD 585-610M (Lumina I) series are modules designed to maximize energy yield from the same roof or ground area. The use of a half-cut architecture and a refined design minimizes losses under load and improves production stability even in less-than-ideal conditions. This translates to more predictable results in the Polish climate, even with occasional cloud cover and lower temperatures.

In terms of competition, these modules stand out due to their high efficiency in the high-power segment and low degradation over time, which supports the long-term profitability of the investment. For installers and designers, compatibility with modern 1500 V systems and a sealed, dust-proof enclosure (IP68) is also important, especially in installations exposed to moisture and dust.

This is a good choice for PV farms, commercial rooftops, and larger prosumer installations, where quick power "packing" and certainty of parameters due to positive power tolerance are important.

Ranking

217 panels in the segment PERC 600-650 W
Metric This panel Median Position in segment Overall rank
Module efficiency 21.55% 21.38% Strong · top 25% 7,784
Power density 215.5 213.8 Strong · top 22% 7,727
Temperature coefficient -0.330 -0.340 Strong · top 6% 8,545
Weight per kWp 56.6 55.7 Typical 10,713
Performance warranty 30 yrs 30 yrs Typical 21
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Signals from the data

3 positive · 0 caution
Best for

Commercial, utility-scale, shaded-installations and residential.

Strengths
-0.330 %/°C temperature coefficient

Top 6% of the PERC 600-650 W segment, against a median of -0.340. Ranked 8,545th in the whole database.

215.5 watts per square metre

Top 22% of the PERC 600-650 W segment, against a median of 213.8.

21.55% module efficiency

Top 25% of the PERC 600-650 W segment, against a median of 21.38%.

Notes from the database
  • At 21.6% efficiency, this panel is on par with typical PERC 600-650W modules
  • Power density of 215.5 W/m² matches the PERC 600-650W median
  • Temperature coefficient of -0.33%/°C matches the PERC 600-650W median
  • Bifacial design (70% factor) captures reflected light - adds 4-10% yield on ground-mount or white roof
  • #7784 for efficiency, #8545 for temperature performance out of 14005 panels

Specifications

Open datasheet PDF
Nominal power (Pmax) 610 Wp Nameplate at 1000 W/m², 25 °C
Module efficiency 21.55 % Strong Segment median 21.38%
Vmpp · Impp 35.20 V · 17.36 A Operating point at max power
Voc · Isc 41.80 V · 18.52 A Sizes the string length
Max system voltage 1500 V Longer strings than 1000 V modules
Dimensions 2172×1303×33 mm · 2.83 m² of roof
Weight 34.5 kg Typical Typical · median 34.0 kg
Cells 120 · PERC Monocrystalline
Bifaciality 70 % Rear output as a share of front
Coefficient Pmax -0.330 %/°C Strong top 6% of its segment
Coefficient Voc · Isc -0.260 · 0.046 %/°C
NOCT 45 °C At 800 W/m², 20 °C ambient
Product warranty 12 years Hardware defects only
Performance warranty 30 years Typical median 30 yrs · median 30 yrs
End-of-warranty output 85.0 % Equals 518 W guaranteed
Degradation 2.00 → 0.45 % First year, then annual

Simulations

Live - change any input
Lifetime output & value
30 years at 1200 kWh/kWp/year and €0.50 per kWh
Power in year 30
-
Lifetime energy
-
Energy value
-
With bifacial gain
-

Degradation from this panel's own datasheet figures. No inverter, soiling or shading losses.

Heat losses
-0.330 %/°C against a segment median of -0.340
-
Bifacial gain
Rear gain over light concrete: -
-

Model: bifaciality × albedo × 0.6 view factor. A first-order estimate, not a yield simulation.

Filter these
Size
Panel Power Eff. Temp. Weight Difference
Runergy SS9-60HD-610M 610 W 21.55% -0.330 34.5 kg You are here
AIKO-A650-MAE72Mw 650 W 25.20% -0.260 27.0 kg Cooler, lighter, +3.6 pp
AIKO-A645-MAE72Mw 645 W 25.00% -0.260 27.0 kg Cooler, lighter, +3.4 pp
LR7-60HVH-560M 560 W 24.80% -0.260 25.0 kg Cooler, lighter, +3.2 pp
AIKO-A640-MAE72Mw 640 W 24.80% -0.260 27.0 kg Cooler, lighter, +3.2 pp
AIKO-A635-MAE72Mw 635 W 24.60% -0.260 27.0 kg Cooler, lighter, +3.1 pp
LR8-66HVD-660M 660 W 24.43% -0.260 33.5 kg +50 W, cooler, +2.9 pp
SS9-60HD-585M 585 W 20.67% -0.330 34.5 kg -25 W, -0.9 pp
SS9-60HD-590M 590 W 20.85% -0.330 34.5 kg -20 W, -0.7 pp
SS9-60HD-595M 595 W 21.02% -0.330 34.5 kg -15 W, -0.5 pp
SS9-60HD-600M 600 W 21.20% -0.330 34.5 kg -10 W, -0.4 pp
SS9-60HD-605M 605 W 21.38% -0.330 34.5 kg Very close match
GKA210N120 680 W 24.03% -0.340 28.0 kg +70 W, lighter, +2.5 pp
GKA210N120-675 675 W 23.85% -0.340 28.0 kg +65 W, lighter, +2.3 pp
QN-670HJT-01 670 W 23.70% -0.240 35.5 kg +60 W, cooler, +2.1 pp
GKA210N120-670 670 W 23.67% -0.340 28.0 kg +60 W, lighter, +2.1 pp
QN-665HJT-01 665 W 23.50% -0.240 35.5 kg +55 W, cooler, +1.9 pp

Found 497 panels of the same or similar size to this one, within ±10 mm. See them here Found 502 panels of the same or similar size to this one, within ±25 mm. See them here Found 502 panels of the same or similar size to this one, within ±50 mm. See them here Found 506 panels of the same or similar size to this one, within ±100 mm. See them here

Common questions

6 answered
What warranties come with the Runergy SS9-60HD 585-610M (Lumina I) series?
Runergy provides a 12-year product warranty covering manufacturing defects and mechanical failures. The linear power output warranty extends to 30 years, guaranteeing at least 84.95% of rated power at end of warranty period. All modules ship with positive power tolerance, meaning each panel meets or exceeds its labeled wattage — eliminating the risk of underperformance straight from the factory.
What does bifacial mean for the Runergy Lumina I, and is it worth the extra cost?
Bifacial technology allows the panel to generate power from both the front face and reflected light hitting the rear side. On ground-mount installations or roofs with light-colored surfaces, this can boost energy yield by several to over ten percent without increasing the footprint. For solar farms and larger prosumer systems, this translates directly to a lower LCOE and faster return on investment.
How do Runergy SS9-60HD Lumina I panels perform in cloudy conditions and cold temperatures?
Very well. The half-cut cell architecture reduces losses from partial shading, which is significant in climates with frequent overcast periods. The temperature coefficient of Pmax is -0.340%/°C — a strong result for PERC technology — meaning the module loses less power during cold winter days and can even exceed its rated output at sub-zero temperatures.
What efficiency do Runergy SS9-60HD 610M panels achieve and how do they compare to the market?
The 610 Wp Lumina I module reaches up to 22.77% efficiency, placing it among the top performers in the PERC segment. Standard PERC modules from a few years ago typically rated 19–20%. In practical terms, the same roof or ground area equipped with Lumina I panels will produce noticeably more energy than older-generation modules.
Are Runergy Lumina I panels compatible with 1500 V inverters and BoS components?
Yes, the SS9-60HD 585-610M modules are rated for 1500 V DC systems, today's standard for commercial and utility-scale installations. This allows longer strings, reducing cabling costs and simplifying system design for MPPT optimization. The IP68-rated junction box ensures reliable performance even in demanding environments with high humidity or dust exposure.
What are the dimensions and weight of the Runergy SS9-60HD 610M panel — will it fit on a standard roof?
The panel measures 2172 × 1303 × 35 mm and weighs approximately 34.5 kg. These are typical dimensions for 600+ Wp large-format modules, primarily designed for solar farms and commercial rooftops. Residential sloped roof installations require a robust racking structure and at least a two-person crew. Always consult a structural engineer to confirm the roof framing can handle the load for the planned array size.
Add to compare