Skip to main content
Found 3,957 inverters
Model Rated AC Type Phase Euro eff. MPPT Max DC kg/kW Warranty
XG5KTL 5 kW Grid-tie 1-ph 97.4% 2 600 V 2.6 kg/kW -
XG5KTR-S 5 kW Grid-tie 3-ph 98.3% 2 1100 V 2.4 kg/kW -
XD5KTL 5 kW Hybrid 1-ph 97.2% 2 600 V 4.3 kg/kW -
XD5KTR 5 kW Hybrid 3-ph 97.6% 2 1100 V 5.4 kg/kW -
SPI5K-B 5 kW Grid-tie 3-ph 98.0% 2 1000 V 3.7 kg/kW -
STS-5KTL-SE 5 kW Grid-tie 1-ph 97.5% 2 600 V 2.3 kg/kW -
STT-5KTL-P 5 kW Grid-tie 3-ph 97.9% 2 1100 V 4.6 kg/kW -
STH-5KTL-LS 5 kW Hybrid 1-ph 97.0% 2 600 V - -
STH-5KTL-LT 5 kW Hybrid 3-ph 97.0% - 1000 V 7.6 kg/kW -
Megarevo R5KL1DA-G2A 5 kW Hybrid 1-ph 96.5% 2 550 V 4.1 kg/kW -
Megarevo O5KL1D 5 kW Off-grid 1-ph - 1 500 V 3.4 kg/kW -
Megarevo R5KLNA 5 kW Hybrid 1-ph 97.8% 4 500 V 9.6 kg/kW -
Megarevo R5KL1DA-G2S 5 kW Hybrid 1-ph 96.5% 2 550 V 4.1 kg/kW -
HP1-5KS2 5 kW Hybrid 1-ph 96.8% 2 500 V 3.0 kg/kW -
HP1-5KS2C 5 kW Hybrid 1-ph 96.8% 2 500 V 3.0 kg/kW -
GT1-5KD2C 5 kW Grid-tie 1-ph 97.0% 2 600 V 2.4 kg/kW -
GT1-5KD2 5 kW Grid-tie 1-ph 97.0% 2 600 V 2.4 kg/kW -
HSSP5K-G01 5 kW Grid-tie 1-ph 97.0% - 600 V 2.6 kg/kW -
HYS-5.0LV-EUG1 5 kW Hybrid 1-ph 97.0% 2 550 V 4.8 kg/kW -
HYT-5.0HV-EUG1 5 kW Hybrid 3-ph 97.0% 2 1000 V 5.3 kg/kW -
Reading this table

Rated AC is the continuous output

The nominal AC power from the datasheet, usually the number in the model name. Where only a maximum is published, that is shown instead.

Euro efficiency, not peak

The figure weighted across part loads, which sits below the peak efficiency a datasheet prints first.

kg per kW

Weight divided by rated power, so a 10 kW and a 3 kW unit can be compared for what they cost to mount.

A dash means no data

The manufacturer did not publish it. We never estimate a missing value.