Skip to main content
Active Bluesun Clear all Found 31 inverters
Model Rated AC Type Phase Euro eff. MPPT Max DC kg/kW Warranty
Bluesun BSM17K-B 17 kW Grid-tie 3-ph 98.3% 2 1100 V 1.2 kg/kW -
Bluesun BSM15K-B 15 kW Grid-tie 3-ph 98.2% 2 1100 V 1.4 kg/kW -
Bluesun BSE12KH3 12 kW Hybrid 3-ph 97.5% 2 1000 V 2.2 kg/kW 5 yr
Bluesun BSE12KLNA 12 kW Hybrid - - 2 550 V 3.5 kg/kW 5 yr
Bluesun BSM-11000BLV-48 11 kW Hybrid 1-ph - 2 500 V 1.6 kg/kW 3 yr
Bluesun BSE10KH3 10 kW Hybrid 3-ph 97.5% 2 1000 V 2.6 kg/kW 5 yr
Bluesun BSE10KLNA 10 kW Hybrid - - 2 550 V 4.2 kg/kW 5 yr
Bluesun BSM-6200LV-48 6.2 kW Hybrid 1-ph - 1 500 V 1.5 kg/kW 3 yr
Bluesun BSE6KL1 6 kW Hybrid 1-ph - 2 550 V 2.8 kg/kW -
Bluesun BSM-5500BLV-48DA 5.5 kW Hybrid 1-ph - 1 500 V 1.5 kg/kW -
Bluesun BSM-4200LV-24 4.2 kW Hybrid 1-ph - 1 500 V 1.9 kg/kW 2 yr
Reading this table

Rated AC is the continuous output

The nominal AC power from the datasheet, usually the number in the model name. Where only a maximum is published, that is shown instead.

Euro efficiency, not peak

The figure weighted across part loads, which sits below the peak efficiency a datasheet prints first.

kg per kW

Weight divided by rated power, so a 10 kW and a 3 kW unit can be compared for what they cost to mount.

A dash means no data

The manufacturer did not publish it. We never estimate a missing value.