Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB156(HCBF)-630W

Philadelphia Solar
PS-MNG144(HCBF)-600W
600 Wp
23.22 %
N-type
Bifacial
VS

Philadelphia Solar
PS-MNB156(HCBF)-630W
630 Wp
22.57 %
N-type
Bifacial
The verdict
MNG144(HCBF)-600W leads on the differences that matter
The largest is module efficiency: 0.65 pp more efficient. 10 of 19 comparable parameters are identical.
See all 9 differencesHow alike are they
10
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
9 of 19 parameters
What actually differs
Parameter
MNG144(HCBF)-600W
MNB156(HCBF)-630W
Difference
Module efficiency
23.22 %
22.57 %
0.65 pp more efficient
Rated power
600 Wp
630 Wp
30 W more power
Power density
232.2 Wp/m²
225.5 Wp/m²
6.7 Wp/m² higher
Module area
2.584 m²
2.794 m²
0.210 m² apart
Open-circuit voltage
52.18 V
55.95 V
3.77 V apart
Cell count
144
156
12 cells apart
Weight per kWp
54.2 kg/kWp
51.6 kg/kWp
2.6 kg/kWp lighter
Voltage at max power
44.58 V
47.27 V
2.69 V apart
Dimensions
2279x1134x30 mm
2464x1134x35 mm
2279x1134x30 mm vs 2464x1134x35 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
MNG144(HCBF)-600W
20,131 kWh
MNB156(HCBF)-630W
21,138 kWh
Lifetime gap
1,007 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
MNG144(HCBF)-600W
MNB156(HCBF)-630W
Standard test conditions
25 °C
100.0% of rated power
600 W
630 W
Cool, bright day
40 °C
95.7% of rated power
574 W
603 W
Typical summer roof
55 °C
91.3% of rated power
548 W
575 W
Hot roof
70 °C
87.0% of rated power
522 W
548 W
03
Full specification
Parameter
MNG144(HCBF)-600W
MNB156(HCBF)-630W
Difference
Power and efficiency
Rated power
600 Wp
630 Wp
+30 W for MNB156(HCBF)-630W
Module efficiency
23.22 %
22.57 %
+0.65 pp for MNG144(HCBF)-600W
Power density
232.2 Wp/m²
225.5 Wp/m²
+6.7 Wp/m² for MNG144(HCBF)-600W
Open-circuit voltage
52.18 V
55.95 V
3.77 V apart
Voltage at max power
44.58 V
47.27 V
2.69 V apart
Short-circuit current
14.25 A
14.10 A
Effectively the same
Current at max power
13.46 A
13.33 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
2279x1134x30 mm
2464x1134x35 mm
2279x1134x30 mm vs 2464x1134x35 mm
Module area
2.584 m²
2.794 m²
0.210 m² apart
Weight
32.5 kg
32.5 kg
Same
Weight per kWp
54.2 kg/kWp
51.6 kg/kWp
-2.6 kg/kWp for MNB156(HCBF)-630W
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
N-type
N-type
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
144
156
12 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#1,289
vs
#3,882
MNG144(HCBF)-600W leads by 2,593 places
Power density
#1,332
vs
#3,891
MNG144(HCBF)-600W leads by 2,559 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#8,370
vs
#4,960
MNB156(HCBF)-630W leads by 3,410 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#2,971
vs
#2,616
MNB156(HCBF)-630W leads by 355 places
05
Open the full database
More useful comparisons
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB156(HCBF)-650W
7 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB156(HCBF)-645W
7 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB156(HCBF)-640W
9 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB156(HCBF)-635W
9 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB144(HCBF)-600W
3 differences, the largest is weight
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB144(HCBF)-595W
3 differences, the largest is weight
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Philadelphia Solar PS-MNG144(HCBF)-600W or Philadelphia Solar PS-MNB156(HCBF)-630W?
According to our database: Philadelphia Solar PS-MNG144(HCBF)-600 W has higher module efficiency (23.22% vs 22.57%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Philadelphia Solar PS-MNG144(HCBF)-600W and Philadelphia Solar PS-MNB156(HCBF)-630W?
Philadelphia Solar PS-MNG144(HCBF)-600 W has a module efficiency of 23.22%, while Philadelphia Solar PS-MNB156(HCBF)-630 W is 22.57%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Philadelphia Solar PS-MNG144(HCBF)-600W use vs Philadelphia Solar PS-MNB156(HCBF)-630W?
Philadelphia Solar PS-MNG144(HCBF)-600 W uses N-type cells; Philadelphia Solar PS-MNB156(HCBF)-630 W uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Philadelphia Solar PS-MNG144(HCBF)-600W and Philadelphia Solar PS-MNB156(HCBF)-630W?
Philadelphia Solar PS-MNG144(HCBF)-600 W has a 30 years power warranty; Philadelphia Solar PS-MNB156(HCBF)-630 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Philadelphia Solar PS-MNG144(HCBF)-600W and Philadelphia Solar PS-MNB156(HCBF)-630W bifacial panels?
Both Philadelphia Solar PS-MNG144(HCBF)-600 W and Philadelphia Solar PS-MNB156(HCBF)-630 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 6 Philadelphia Solar offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.