MNG144(HCBF)-600W vs MNB144(HCBF)-600W 16 of 19 identical Swap Change panels

Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB144(HCBF)-600W

Philadelphia Solar PS-MNG144(HCBF)-600W
Philadelphia Solar
PS-MNG144(HCBF)-600W
600 Wp 23.22 % N-type Bifacial
VS
Philadelphia Solar PS-MNB144(HCBF)-600W
Philadelphia Solar
PS-MNB144(HCBF)-600W
600 Wp 23.23 % N-type Bifacial
The verdict

MNB144(HCBF)-600W leads on the differences that matter

The largest is weight: 5.5 kg lighter. 16 of 19 comparable parameters are identical.

See all 3 differences
How alike are they
16 of 19 comparable
parameters are identical
identical differs
01

What actually differs

3 of 19 parameters
Parameter MNG144(HCBF)-600W MNB144(HCBF)-600W Difference
Weight 32.5 kg 27.0 kg 5.5 kg lighter
Weight per kWp 54.2 kg/kWp 45.0 kg/kWp 9.2 kg/kWp lighter
Dimensions 2279x1134x30 mm 2278x1134x30 mm 2279x1134x30 mm vs 2278x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
MNG144(HCBF)-600W
20,131 kWh
MNB144(HCBF)-600W
20,131 kWh
Lifetime gap
No difference
Output when it is hot
Rated power carried across the range a module actually sees
Scenario MNG144(HCBF)-600W MNB144(HCBF)-600W
Standard test conditions 25 °C 100.0% of rated power 600 W 600 W
Cool, bright day 40 °C 95.7% of rated power 574 W 574 W
Typical summer roof 55 °C 91.3% of rated power 548 W 548 W
Hot roof 70 °C 87.0% of rated power 522 W 522 W
03

Full specification

Parameter MNG144(HCBF)-600W MNB144(HCBF)-600W Difference
Power and efficiency
Rated power 600 Wp 600 Wp Same
Module efficiency 23.22 % 23.23 % Effectively the same
Power density 232.2 Wp/m² 232.3 Wp/m² Effectively the same
Open-circuit voltage 52.18 V 52.21 V Effectively the same
Voltage at max power 44.58 V 44.57 V Effectively the same
Short-circuit current 14.25 A 14.26 A Effectively the same
Current at max power 13.46 A 13.47 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 2279x1134x30 mm 2278x1134x30 mm 2279x1134x30 mm vs 2278x1134x30 mm
Module area 2.584 m² 2.583 m² Effectively the same
Weight 32.5 kg 27.0 kg -5.5 kg for MNB144(HCBF)-600W
Weight per kWp 54.2 kg/kWp 45.0 kg/kWp -9.2 kg/kWp for MNB144(HCBF)-600W
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology N-type N-type Same
Cell type Monocrystalline Monocrystalline Same
Cell count 144 144 Same
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#1,289 vs #1,252
MNB144(HCBF)-600W leads by 37 places
Power density
#1,332 vs #1,252
MNB144(HCBF)-600W leads by 80 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#8,370 vs #574
MNB144(HCBF)-600W leads by 7,796 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#2,971 vs #2,803
MNB144(HCBF)-600W leads by 168 places
05

More useful comparisons

Open the full database
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB156(HCBF)-650W
7 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB156(HCBF)-645W
7 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB156(HCBF)-640W
9 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB156(HCBF)-635W
9 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB156(HCBF)-630W
9 differences, the largest is module efficiency
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNG144(HCBF)-600W vs Philadelphia Solar PS-MNB144(HCBF)-595W
3 differences, the largest is weight
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Philadelphia Solar PS-MNG144(HCBF)-600W or Philadelphia Solar PS-MNB144(HCBF)-600W?
According to our database: Philadelphia Solar PS-MNB144(HCBF)-600 W has higher module efficiency (23.23% vs 23.22%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Philadelphia Solar PS-MNG144(HCBF)-600W and Philadelphia Solar PS-MNB144(HCBF)-600W?
Philadelphia Solar PS-MNG144(HCBF)-600 W has a module efficiency of 23.22%, while Philadelphia Solar PS-MNB144(HCBF)-600 W is 23.23%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Philadelphia Solar PS-MNG144(HCBF)-600W use vs Philadelphia Solar PS-MNB144(HCBF)-600W?
Philadelphia Solar PS-MNG144(HCBF)-600 W uses N-type cells; Philadelphia Solar PS-MNB144(HCBF)-600 W uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Philadelphia Solar PS-MNG144(HCBF)-600W and Philadelphia Solar PS-MNB144(HCBF)-600W?
Philadelphia Solar PS-MNG144(HCBF)-600 W has a 30 years power warranty; Philadelphia Solar PS-MNB144(HCBF)-600 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Philadelphia Solar PS-MNG144(HCBF)-600W and Philadelphia Solar PS-MNB144(HCBF)-600W bifacial panels?
Both Philadelphia Solar PS-MNG144(HCBF)-600 W and Philadelphia Solar PS-MNB144(HCBF)-600 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 6 Philadelphia Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.