Solplanet Ai-HB 075A vs Dyness Tower Pro TP7
VS
The verdict
Tower Pro TP7 leads on the differences that matter
The largest is usable energy: 0.39 kWh apart. 7 of 23 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
7
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 23 parameters
What actually differs
Parameter
Ai-HB 075A
Tower Pro TP7
Difference
Usable energy
6.91 kWh
7.30 kWh
0.39 kWh apart
Continuous discharge power
4.61 kW
7.68 kW
3.07 kW more power
Cycle life
6000 cycles
8000 cycles
2000 cycles more
Max system capacity
20.5 kWh
23.0 kWh
2.6 kWh more room to expand
Depth of discharge
90 %
95 %
5 pp more of the cells usable
Continuous charge power
3.84 kW
7.68 kW
3.84 kW faster charging
Power per kWh
0.67 kW/kWh
1.05 kW/kWh
0.39 kW/kWh more power for its size
Nominal voltage
154 V
192 V
38 V apart
Weight
106.5 kg
99.5 kg
7.0 kg lighter
Weight per kWh
15.4 kg/kWh
13.6 kg/kWh
1.8 kg/kWh lighter
Cycle test depth
80 %
95 %
15 pp apart
Max operating temperature
50 °C
55 °C
5 °C more heat tolerant
Ingress protection
IP65
IP55
IP65 vs IP55
Modules per stack
3-8
2-6
3-8 vs 2-6
Operating voltage
120-175.2 V
168-219 V
120-175.2 V vs 168-219 V
Dimensions
600x540x390 mm
788x587x310 mm
600x540x390 mm vs 788x587x310 mm
02
1 shop we track
Price offers
Shop
Ai-HB 075A
Tower Pro TP7
At this shop
Shop prices by brand: See 4 Solplanet offers · See 20 Dyness offers
03
Full specification
Parameter
Ai-HB 075A
Tower Pro TP7
Difference
Capacity
Usable energy
6.91 kWh
7.30 kWh
0.39 kWh apart
Nominal energy
7.68 kWh
7.68 kWh
Same
Depth of discharge
90 %
95 %
+5 pp for Tower Pro TP7
Max system capacity
20.5 kWh
23.0 kWh
+2.6 kWh for Tower Pro TP7
Modules per stack
3-8
2-6
3-8 vs 2-6
Power
Continuous discharge power
4.61 kW
7.68 kW
+3.07 kW for Tower Pro TP7
Continuous charge power
3.84 kW
7.68 kW
+3.84 kW for Tower Pro TP7
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
0.67 kW/kWh
1.05 kW/kWh
+0.39 kW/kWh for Tower Pro TP7
Efficiency and lifetime
Round-trip efficiency
95.0 %
95.0 %
Same
Cycle life
6000 cycles
8000 cycles
+2000 cycles for Tower Pro TP7
Cycle test depth
80 %
95 %
15 pp apart
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
154 V
192 V
38 V apart
Operating voltage
120-175.2 V
168-219 V
120-175.2 V vs 168-219 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
106.5 kg
99.5 kg
-7.0 kg for Tower Pro TP7
Weight per kWh
15.4 kg/kWh
13.6 kg/kWh
-1.8 kg/kWh for Tower Pro TP7
Dimensions
600x540x390 mm
788x587x310 mm
600x540x390 mm vs 788x587x310 mm
Ingress protection
IP65
IP55
IP65 vs IP55
Outdoor-rated
Yes
Yes
Same
Min operating temperature
-20 °C
-20 °C
Same
Max operating temperature
50 °C
55 °C
+5 °C for Tower Pro TP7
Warranty
Warranty
-
15 yrs
Not published by Solplanet
Warranted throughput
-
-
Neither datasheet publishes this
04
Open all batteries
More useful comparisons
Similar capacity
Solplanet Ai-HB 075A vs Dyness Tower T7
13 differences, the largest is usable energy
Similar capacity
Solplanet Ai-HB 075A vs FoxESS HS7.5
8 differences, the largest is usable energy
Similar capacity
Solplanet Ai-HB 075A vs SMA Home Storage 6.5
17 differences, the largest is usable energy
Similar capacity
Dyness Tower Pro TP7 vs Deye GB-L8
16 differences, the largest is continuous discharge power
Similar capacity
Dyness Tower Pro TP7 vs Deye GB-SL-EU (2 modules in series)
15 differences, the largest is cycle life
Similar capacity
Dyness Tower Pro TP7 vs FoxESS ECS4300H-H2
13 differences, the largest is usable energy
05
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.