Skip to main content
Tower Pro TP7 vs GB-L8 6 of 22 identical Swap Change batteries

Dyness Tower Pro TP7 vs Deye GB-L8

Dyness Tower Pro TP7
Tower Pro TP7
7.3 kWh 95.0 % round-trip LFP HV
VS
Deye GB-L8
GB-L8
7.36 kWh LFP HV
The verdict

16 differences, and they point both ways

The largest is continuous discharge power: 0.51 kW more power. 6 of 22 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
6 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 22 parameters
Parameter Tower Pro TP7 GB-L8 Difference
Continuous discharge power 7.68 kW 8.19 kW 0.51 kW more power
Cycle life 8000 cycles 6000 cycles 2000 cycles more
Warranty 15 yrs 10 yrs 5 yrs longer
Max system capacity 23.0 kWh 24.5 kWh 1.5 kWh more room to expand
Nominal energy 7.68 kWh 8.18 kWh 0.50 kWh apart
Depth of discharge 95 % 90 % 5 pp more of the cells usable
Continuous charge power 7.68 kW 8.19 kW 0.51 kW faster charging
Nominal voltage 192 V 205 V 13 V apart
Weight 99.5 kg 97.0 kg 2.5 kg lighter
Usable energy 7.30 kWh 7.36 kWh 0.06 kWh apart
Max operating temperature 55 °C 60 °C 5 °C more heat tolerant
Weight per kWh 13.6 kg/kWh 13.2 kg/kWh 0.5 kg/kWh lighter
Ingress protection IP55 IP65 IP55 vs IP65
Power per kWh 1.05 kW/kWh 1.11 kW/kWh 0.06 kW/kWh more power for its size
Operating voltage 168-219 V 166.4-700 V 168-219 V vs 166.4-700 V
Dimensions 788x587x310 mm 650x540x385 mm 788x587x310 mm vs 650x540x385 mm
02

Price offers

1 shop we track
Shop Tower Pro TP7 GB-L8 At this shop
Sklep Soltech Poland 7 359.52 zł net - Only Tower Pro TP7

All 1 offer for Tower Pro TP7

Shop prices by brand: See 20 Dyness offers · See 44 Deye offers

03

Full specification

Parameter Tower Pro TP7 GB-L8 Difference
Capacity
Usable energy 7.30 kWh 7.36 kWh 0.06 kWh apart
Nominal energy 7.68 kWh 8.18 kWh 0.50 kWh apart
Depth of discharge 95 % 90 % +5 pp for Tower Pro TP7
Max system capacity 23.0 kWh 24.5 kWh +1.5 kWh for GB-L8
Modules per stack 2-6 2-6 Same
Power
Continuous discharge power 7.68 kW 8.19 kW +0.51 kW for GB-L8
Continuous charge power 7.68 kW 8.19 kW +0.51 kW for GB-L8
Peak discharge power - 10.24 kW Not published by Dyness
Power per kWh 1.05 kW/kWh 1.11 kW/kWh +0.06 kW/kWh for GB-L8
Efficiency and lifetime
Round-trip efficiency 95.0 % - Not published by Deye
Cycle life 8000 cycles 6000 cycles +2000 cycles for Tower Pro TP7
Cycle test depth 95 % - Not published by Deye
Capacity at end of life - 70 % Not published by Dyness
Self-discharge - - Neither datasheet publishes this
Electrical
Voltage class High voltage High voltage Same
Nominal voltage 192 V 205 V 13 V apart
Operating voltage 168-219 V 166.4-700 V 168-219 V vs 166.4-700 V
Cell chemistry LFP LFP Same
Active cell balancing - - Neither datasheet publishes this
Thermal management - Yes Not published by Dyness
Built-in inverter
Inverter None (battery only) None (battery only) Same
Inverter power - - Neither datasheet publishes this
Grid connection - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 99.5 kg 97.0 kg -2.5 kg for GB-L8
Weight per kWh 13.6 kg/kWh 13.2 kg/kWh -0.5 kg/kWh for GB-L8
Dimensions 788x587x310 mm 650x540x385 mm 788x587x310 mm vs 650x540x385 mm
Ingress protection IP55 IP65 IP55 vs IP65
Outdoor-rated Yes Yes Same
Min operating temperature -20 °C -20 °C Same
Max operating temperature 55 °C 60 °C +5 °C for GB-L8
Warranty
Warranty 15 yrs 10 yrs +5 yrs for Tower Pro TP7
Warranted throughput - - Neither datasheet publishes this
04

More useful comparisons

Open all batteries
Similar capacity
Dyness Tower Pro TP7 vs Deye GB-SL-EU (2 modules in series)
15 differences, the largest is cycle life
Similar capacity
Dyness Tower Pro TP7 vs FoxESS HS7.5
11 differences, the largest is cycle life
Similar capacity
Dyness Tower Pro TP7 vs FoxESS ECS4300H-H2
13 differences, the largest is usable energy
05

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.