Dyness Tower T17 vs Deye GB-L20
VS
The verdict
GB-L20 leads on the differences that matter
The largest is usable energy: 0.64 kWh apart. 5 of 18 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
5
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 18 parameters
What actually differs
Parameter
Tower T17
GB-L20
Difference
Usable energy
17.76 kWh
18.40 kWh
0.64 kWh apart
Continuous discharge power
10.65 kW
20.48 kW
9.83 kW more power
Nominal energy
17.76 kWh
20.45 kWh
2.69 kWh apart
Depth of discharge
100 %
90 %
10 pp more of the cells usable
Continuous charge power
10.65 kW
20.48 kW
9.83 kW faster charging
Power per kWh
0.60 kW/kWh
1.11 kW/kWh
0.51 kW/kWh more power for its size
Nominal voltage
480 V
512 V
32 V apart
Weight
228.0 kg
214.0 kg
14.0 kg lighter
Weight per kWh
12.8 kg/kWh
11.6 kg/kWh
1.2 kg/kWh lighter
Min operating temperature
-10 °C
-20 °C
10 °C more cold tolerant
Max operating temperature
50 °C
60 °C
10 °C more heat tolerant
Ingress protection
IP54
IP65
IP54 vs IP65
Dimensions
1300x504x380 mm
1310x540x385 mm
1300x504x380 mm vs 1310x540x385 mm
Shop prices by brand: See 20 Dyness offers · See 44 Deye offers
02
Full specification
Parameter
Tower T17
GB-L20
Difference
Capacity
Usable energy
17.76 kWh
18.40 kWh
0.64 kWh apart
Nominal energy
17.76 kWh
20.45 kWh
2.69 kWh apart
Depth of discharge
100 %
90 %
+10 pp for Tower T17
Max system capacity
-
24.5 kWh
Not published by Dyness
Modules per stack
2-6
2-6
Same
Power
Continuous discharge power
10.65 kW
20.48 kW
+9.83 kW for GB-L20
Continuous charge power
10.65 kW
20.48 kW
+9.83 kW for GB-L20
Peak discharge power
-
25.60 kW
Not published by Dyness
Power per kWh
0.60 kW/kWh
1.11 kW/kWh
+0.51 kW/kWh for GB-L20
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
-
-
Neither datasheet publishes this
Capacity at end of life
-
70 %
Not published by Dyness
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
480 V
512 V
32 V apart
Operating voltage
-
166.4-700 V
Not published by Dyness
Cell chemistry
-
LFP
Not published by Dyness
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
Yes
Not published by Dyness
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
228.0 kg
214.0 kg
-14.0 kg for GB-L20
Weight per kWh
12.8 kg/kWh
11.6 kg/kWh
-1.2 kg/kWh for GB-L20
Dimensions
1300x504x380 mm
1310x540x385 mm
1300x504x380 mm vs 1310x540x385 mm
Ingress protection
IP54
IP65
IP54 vs IP65
Outdoor-rated
-
Yes
Not published by Dyness
Min operating temperature
-10 °C
-20 °C
-10 °C for GB-L20
Max operating temperature
50 °C
60 °C
+10 °C for GB-L20
Warranty
Warranty
10 yrs
10 yrs
Same
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
Dyness Tower T17 vs FoxESS ECS2900-H7
9 differences, the largest is usable energy
Similar capacity
Dyness Tower T17 vs Dyness Tower Pro TP19
14 differences, the largest is usable energy
Similar capacity
Dyness Tower T17 vs Deye GB-SL-EU (5 modules in series)
11 differences, the largest is usable energy
Similar capacity
Deye GB-L20 vs Solplanet Ai-HB 200A
11 differences, the largest is continuous discharge power
Similar capacity
Deye GB-L20 vs Deye BOS-G20
9 differences, the largest is max system capacity
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.