Deye GB-L20 vs Dyness Tower T17
VS
The verdict
GB-L20 leads on the differences that matter
The largest is usable energy: 0.64 kWh apart. 5 of 18 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
5
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 18 parameters
What actually differs
Parameter
GB-L20
Tower T17
Difference
Usable energy
18.40 kWh
17.76 kWh
0.64 kWh apart
Continuous discharge power
20.48 kW
10.65 kW
9.83 kW more power
Nominal energy
20.45 kWh
17.76 kWh
2.69 kWh apart
Depth of discharge
90 %
100 %
10 pp more of the cells usable
Continuous charge power
20.48 kW
10.65 kW
9.83 kW faster charging
Power per kWh
1.11 kW/kWh
0.60 kW/kWh
0.51 kW/kWh more power for its size
Nominal voltage
512 V
480 V
32 V apart
Weight
214.0 kg
228.0 kg
14.0 kg lighter
Weight per kWh
11.6 kg/kWh
12.8 kg/kWh
1.2 kg/kWh lighter
Min operating temperature
-20 °C
-10 °C
10 °C more cold tolerant
Max operating temperature
60 °C
50 °C
10 °C more heat tolerant
Ingress protection
IP65
IP54
IP65 vs IP54
Dimensions
1310x540x385 mm
1300x504x380 mm
1310x540x385 mm vs 1300x504x380 mm
Shop prices by brand: See 44 Deye offers · See 20 Dyness offers
02
Full specification
Parameter
GB-L20
Tower T17
Difference
Capacity
Usable energy
18.40 kWh
17.76 kWh
0.64 kWh apart
Nominal energy
20.45 kWh
17.76 kWh
2.69 kWh apart
Depth of discharge
90 %
100 %
+10 pp for Tower T17
Max system capacity
24.5 kWh
-
Not published by Dyness
Modules per stack
2-6
2-6
Same
Power
Continuous discharge power
20.48 kW
10.65 kW
+9.83 kW for GB-L20
Continuous charge power
20.48 kW
10.65 kW
+9.83 kW for GB-L20
Peak discharge power
25.60 kW
-
Not published by Dyness
Power per kWh
1.11 kW/kWh
0.60 kW/kWh
+0.51 kW/kWh for GB-L20
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
-
-
Neither datasheet publishes this
Capacity at end of life
70 %
-
Not published by Dyness
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
512 V
480 V
32 V apart
Operating voltage
166.4-700 V
-
Not published by Dyness
Cell chemistry
LFP
-
Not published by Dyness
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
Yes
-
Not published by Dyness
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
214.0 kg
228.0 kg
-14.0 kg for GB-L20
Weight per kWh
11.6 kg/kWh
12.8 kg/kWh
-1.2 kg/kWh for GB-L20
Dimensions
1310x540x385 mm
1300x504x380 mm
1310x540x385 mm vs 1300x504x380 mm
Ingress protection
IP65
IP54
IP65 vs IP54
Outdoor-rated
Yes
-
Not published by Dyness
Min operating temperature
-20 °C
-10 °C
-10 °C for GB-L20
Max operating temperature
60 °C
50 °C
+10 °C for GB-L20
Warranty
Warranty
10 yrs
10 yrs
Same
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
Deye GB-L20 vs Deye GB-SL-EU (5 modules in series)
5 differences, the largest is weight
Similar capacity
Deye GB-L20 vs Solplanet Ai-HB 200A
11 differences, the largest is continuous discharge power
Similar capacity
Deye GB-L20 vs Deye BOS-G20
9 differences, the largest is max system capacity
Similar capacity
Dyness Tower T17 vs FoxESS ECS2900-H7
9 differences, the largest is usable energy
Similar capacity
Dyness Tower T17 vs Dyness Tower Pro TP19
14 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.