Deye RW-F10.2-B vs Deye RW-G10.6
VS
The verdict
10 differences, and they point both ways
The largest is usable energy: 0.38 kWh apart. 10 of 20 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
10
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 20 parameters
What actually differs
Parameter
F10.2-B
G10.6
Difference
Usable energy
9.20 kWh
9.58 kWh
0.38 kWh apart
Warranty
10 yrs
5 yrs
5 yrs longer
Max system capacity
294.4 kWh
306.6 kWh
12.2 kWh more room to expand
Nominal energy
10.24 kWh
10.64 kWh
0.40 kWh apart
Weight
107.0 kg
90.0 kg
17.0 kg lighter
Weight per kWh
11.6 kg/kWh
9.4 kg/kWh
2.2 kg/kWh lighter
Warranted throughput
32.0 MWh
16.0 MWh
16.0 MWh more
Ingress protection
IP65
IP20
IP65 vs IP20
Operating voltage
43.2-57.6 V
44.8-57.6 V
43.2-57.6 V vs 44.8-57.6 V
Dimensions
830x600x200 mm
750x600x200 mm
830x600x200 mm vs 750x600x200 mm
02
1 shop we track
Price offers
Shop
F10.2-B
G10.6
At this shop
Shop prices by brand: See 44 Deye offers
03
Full specification
Parameter
F10.2-B
G10.6
Difference
Capacity
Usable energy
9.20 kWh
9.58 kWh
0.38 kWh apart
Nominal energy
10.24 kWh
10.64 kWh
0.40 kWh apart
Depth of discharge
90 %
90 %
Same
Max system capacity
294.4 kWh
306.6 kWh
+12.2 kWh for G10.6
Modules per stack
-
-
Neither datasheet publishes this
Power
Continuous discharge power
12.29 kW
-
Not published by Deye
Continuous charge power
10.14 kW
-
Not published by Deye
Peak discharge power
15.36 kW
-
Not published by Deye
Power per kWh
1.34 kW/kWh
-
Not published by Deye
Efficiency and lifetime
Round-trip efficiency
-
90.0 %
Not published by Deye
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
90 %
90 %
Same
Capacity at end of life
70 %
70 %
Same
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
Low voltage
Low voltage
Same
Nominal voltage
51 V
51 V
Same
Operating voltage
43.2-57.6 V
44.8-57.6 V
43.2-57.6 V vs 44.8-57.6 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
107.0 kg
90.0 kg
-17.0 kg for G10.6
Weight per kWh
11.6 kg/kWh
9.4 kg/kWh
-2.2 kg/kWh for G10.6
Dimensions
830x600x200 mm
750x600x200 mm
830x600x200 mm vs 750x600x200 mm
Ingress protection
IP65
IP20
IP65 vs IP20
Outdoor-rated
-
-
Neither datasheet publishes this
Min operating temperature
-20 °C
-20 °C
Same
Max operating temperature
55 °C
55 °C
Same
Warranty
Warranty
10 yrs
5 yrs
+5 yrs for F10.2-B
Warranted throughput
32.0 MWh
16.0 MWh
+16.0 MWh for F10.2-B
04
Open all batteries
More useful comparisons
Similar capacity
Deye RW-F10.2-B vs Deye RW-F10.2
3 differences, the largest is weight
Similar capacity
Deye RW-F10.2-B vs Deye AI-W5.1-B (2 modules)
10 differences, the largest is continuous discharge power
Similar capacity
Deye RW-F10.2-B vs FelicityESS LUX-E-48200LG03
10 differences, the largest is usable energy
05
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.