Deye RW-F10.2-B vs Deye AI-W5.1-B (2 modules)
VS
The verdict
RW-F10.2-B leads on the differences that matter
The largest is continuous discharge power: 3.07 kW more power. 14 of 24 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
14
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 24 parameters
What actually differs
Parameter
RW-F10.2-B
AI-W5.1-B (2 modules)
Difference
Continuous discharge power
12.29 kW
9.22 kW
3.07 kW more power
Max system capacity
294.4 kWh
30.7 kWh
263.7 kWh more room to expand
Continuous charge power
10.14 kW
9.22 kW
0.92 kW faster charging
Peak discharge power
15.36 kW
13.82 kW
1.54 kW more surge
Power per kWh
1.34 kW/kWh
1.00 kW/kWh
0.33 kW/kWh more power for its size
Weight
107.0 kg
127.5 kg
20.5 kg lighter
Weight per kWh
11.6 kg/kWh
13.9 kg/kWh
2.2 kg/kWh lighter
Warranted throughput
32.0 MWh
16.0 MWh
16.0 MWh more
Ingress protection
IP65
IP65 (after stacking)
IP65 vs IP65 (after stacking)
Dimensions
830x600x200 mm
850x720x255 mm
830x600x200 mm vs 850x720x255 mm
02
1 shop we track
Price offers
Shop
RW-F10.2-B
AI-W5.1-B (2 modules)
At this shop
Shop prices by brand: See 44 Deye offers
03
Full specification
Parameter
RW-F10.2-B
AI-W5.1-B (2 modules)
Difference
Capacity
Usable energy
9.20 kWh
9.20 kWh
Same
Nominal energy
10.24 kWh
10.24 kWh
Same
Depth of discharge
90 %
90 %
Same
Max system capacity
294.4 kWh
30.7 kWh
+263.7 kWh for RW-F10.2-B
Modules per stack
-
1-6
Not published by Deye
Power
Continuous discharge power
12.29 kW
9.22 kW
+3.07 kW for RW-F10.2-B
Continuous charge power
10.14 kW
9.22 kW
+0.92 kW for RW-F10.2-B
Peak discharge power
15.36 kW
13.82 kW
+1.54 kW for RW-F10.2-B
Power per kWh
1.34 kW/kWh
1.00 kW/kWh
+0.33 kW/kWh for RW-F10.2-B
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
90 %
90 %
Same
Capacity at end of life
70 %
70 %
Same
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
Low voltage
Low voltage
Same
Nominal voltage
51 V
51 V
Same
Operating voltage
43.2-57.6 V
43.2-57.6 V
Same
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
107.0 kg
127.5 kg
-20.5 kg for RW-F10.2-B
Weight per kWh
11.6 kg/kWh
13.9 kg/kWh
-2.2 kg/kWh for RW-F10.2-B
Dimensions
830x600x200 mm
850x720x255 mm
830x600x200 mm vs 850x720x255 mm
Ingress protection
IP65
IP65 (after stacking)
IP65 vs IP65 (after stacking)
Outdoor-rated
-
-
Neither datasheet publishes this
Min operating temperature
-20 °C
-20 °C
Same
Max operating temperature
55 °C
55 °C
Same
Warranty
Warranty
10 yrs
10 yrs
Same
Warranted throughput
32.0 MWh
16.0 MWh
+16.0 MWh for RW-F10.2-B
04
Open all batteries
More useful comparisons
05
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.