Skip to main content
BOS-G80 Pro vs BC100DE 3 of 14 identical Swap Change batteries

Deye BOS-G80 Pro vs KSTAR BC100DE

Deye BOS-G80 Pro
BOS-G80 Pro
73.73 kWh LFP HV
VS
KSTAR BC100DE
BC100DE
92.16 kWh LFP HV
The verdict

BOS-G80 Pro leads on the differences that matter

The largest is usable energy: 18.43 kWh apart. 3 of 14 comparable parameters are identical, with 19 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
3 of 14 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 14 parameters
Parameter BOS-G80 Pro BC100DE Difference
Usable energy 73.73 kWh 92.16 kWh 18.43 kWh apart
Nominal energy 81.92 kWh 102.40 kWh 20.48 kWh apart
Nominal voltage 819 V 512 V 307 V apart
Weight 837.0 kg 1500.0 kg 663.0 kg lighter
Weight per kWh 11.4 kg/kWh 16.3 kg/kWh 4.9 kg/kWh lighter
Min operating temperature -20 °C -30 °C 10 °C more cold tolerant
Max operating temperature 55 °C 50 °C 5 °C more heat tolerant
Inverter None (battery only) Built in (all-in-one) None (battery only) vs Built in (all-in-one)
Ingress protection IP20 (battery enclosure) IP54 (battery cabinet); IP65 (inverter) IP20 (battery enclosure) vs IP54 (battery cabinet); IP65 (inverter)
Operating voltage 704-934.4 V 456-576 V 704-934.4 V vs 456-576 V
Dimensions 1629x1060x602 mm 2380x1100x1100 mm 1629x1060x602 mm vs 2380x1100x1100 mm

Shop prices by brand: See 44 Deye offers

02

Full specification

Parameter BOS-G80 Pro BC100DE Difference
Capacity
Usable energy 73.73 kWh 92.16 kWh 18.43 kWh apart
Nominal energy 81.92 kWh 102.40 kWh 20.48 kWh apart
Depth of discharge 90 % 90 % Same
Max system capacity 81.9 kWh - Not published by KSTAR
Modules per stack 5-16 - Not published by KSTAR
Power
Continuous discharge power 81.92 kW - Not published by KSTAR
Continuous charge power 81.92 kW - Not published by KSTAR
Peak discharge power 102.40 kW - Not published by KSTAR
Power per kWh 1.11 kW/kWh - Not published by KSTAR
Efficiency and lifetime
Round-trip efficiency - - Neither datasheet publishes this
Cycle life 6000 cycles - Not published by KSTAR
Cycle test depth 90 % - Not published by KSTAR
Capacity at end of life 70 % - Not published by KSTAR
Self-discharge - - Neither datasheet publishes this
Electrical
Voltage class High voltage High voltage Same
Nominal voltage 819 V 512 V 307 V apart
Operating voltage 704-934.4 V 456-576 V 704-934.4 V vs 456-576 V
Cell chemistry LFP LFP Same
Active cell balancing - - Neither datasheet publishes this
Thermal management - Yes Not published by Deye
Built-in inverter
Inverter None (battery only) Built in (all-in-one) None (battery only) vs Built in (all-in-one)
Inverter power - 50.0 kW Not published by Deye
Grid connection - 3-phase Not published by Deye
Backup power - 50.0 kW Not published by Deye
Physical
Weight 837.0 kg 1500.0 kg -663.0 kg for BOS-G80 Pro
Weight per kWh 11.4 kg/kWh 16.3 kg/kWh -4.9 kg/kWh for BOS-G80 Pro
Dimensions 1629x1060x602 mm 2380x1100x1100 mm 1629x1060x602 mm vs 2380x1100x1100 mm
Ingress protection IP20 (battery enclosure) IP54 (battery cabinet); IP65 (inverter) IP20 (battery enclosure) vs IP54 (battery cabinet); IP65 (inverter)
Outdoor-rated - Yes Not published by Deye
Min operating temperature -20 °C -30 °C -10 °C for BC100DE
Max operating temperature 55 °C 50 °C +5 °C for BOS-G80 Pro
Warranty
Warranty 10 yrs - Not published by KSTAR
Warranted throughput - - Neither datasheet publishes this
03

More useful comparisons

Open all batteries
Similar capacity
Deye BOS-G80 Pro vs Deye BOS-A (11 modules in series)
10 differences, the largest is usable energy
Similar capacity
Deye BOS-G80 Pro vs Deye GE-F60-EU
13 differences, the largest is usable energy
Similar capacity
Deye BOS-G80 Pro vs Deye BOS-G60 Pro
9 differences, the largest is usable energy
Similar capacity
KSTAR BC100DE vs Huawei LUNA2000-97KWH-1H1
9 differences, the largest is usable energy
Similar capacity
KSTAR BC100DE vs GoodWe LX C101-10
9 differences, the largest is usable energy
Similar capacity
KSTAR BC100DE vs Deye BOS-A (15 modules in series)
11 differences, the largest is usable energy
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.