KSTAR BC100DE vs GoodWe LX C101-10
VS
The verdict
LX C101-10 leads on the differences that matter
The largest is usable energy: 9.22 kWh apart. 3 of 12 comparable parameters are identical, with 21 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
3
of 12 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 12 parameters
What actually differs
Parameter
BC100DE
LX C101-10
Difference
Usable energy
92.16 kWh
101.38 kWh
9.22 kWh apart
Nominal voltage
512 V
422 V
90 V apart
Weight
1500.0 kg
1120.0 kg
380.0 kg lighter
Weight per kWh
16.3 kg/kWh
11.0 kg/kWh
5.2 kg/kWh lighter
Min operating temperature
-30 °C
-20 °C
10 °C more cold tolerant
Inverter
Built in (all-in-one)
None (battery only)
Built in (all-in-one) vs None (battery only)
Ingress protection
IP54 (battery cabinet); IP65 (inverter)
IP21
IP54 (battery cabinet); IP65 (inverter) vs IP21
Operating voltage
456-576 V
369.6-468.6 V
456-576 V vs 369.6-468.6 V
Dimensions
2380x1100x1100 mm
1650x1155x730 mm
2380x1100x1100 mm vs 1650x1155x730 mm
Shop prices by brand: See 38 GoodWe offers
02
Full specification
Parameter
BC100DE
LX C101-10
Difference
Capacity
Usable energy
92.16 kWh
101.38 kWh
9.22 kWh apart
Nominal energy
102.40 kWh
-
Not published by GoodWe
Depth of discharge
90 %
-
Not published by GoodWe
Max system capacity
-
156.6 kWh
Not published by KSTAR
Modules per stack
-
11-17
Not published by KSTAR
Power
Continuous discharge power
-
42.24 kW
Not published by KSTAR
Continuous charge power
-
42.24 kW
Not published by KSTAR
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
-
0.42 kW/kWh
Not published by KSTAR
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
-
-
Neither datasheet publishes this
Cycle test depth
-
100 %
Not published by KSTAR
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
512 V
422 V
90 V apart
Operating voltage
456-576 V
369.6-468.6 V
456-576 V vs 369.6-468.6 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
Yes
-
Not published by GoodWe
Built-in inverter
Inverter
Built in (all-in-one)
None (battery only)
Built in (all-in-one) vs None (battery only)
Inverter power
50.0 kW
-
Not published by GoodWe
Grid connection
3-phase
-
Not published by GoodWe
Backup power
50.0 kW
-
Not published by GoodWe
Physical
Weight
1500.0 kg
1120.0 kg
-380.0 kg for LX C101-10
Weight per kWh
16.3 kg/kWh
11.0 kg/kWh
-5.2 kg/kWh for LX C101-10
Dimensions
2380x1100x1100 mm
1650x1155x730 mm
2380x1100x1100 mm vs 1650x1155x730 mm
Ingress protection
IP54 (battery cabinet); IP65 (inverter)
IP21
IP54 (battery cabinet); IP65 (inverter) vs IP21
Outdoor-rated
Yes
-
Not published by GoodWe
Min operating temperature
-30 °C
-20 °C
-10 °C for BC100DE
Max operating temperature
50 °C
50 °C
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
KSTAR BC100DE vs Huawei LUNA2000-97KWH-1H1
9 differences, the largest is usable energy
Similar capacity
KSTAR BC100DE vs Deye BOS-A (15 modules in series)
11 differences, the largest is usable energy
Similar capacity
KSTAR BC100DE vs Deye BOS-A (11 modules in series)
11 differences, the largest is usable energy
Similar capacity
GoodWe LX C101-10 vs GoodWe LX C120-10
7 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.