GoodWe LX C101-10 vs KSTAR BC100DE
VS
The verdict
LX C101-10 leads on the differences that matter
The largest is usable energy: 9.22 kWh apart. 3 of 12 comparable parameters are identical, with 21 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
3
of 12 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 12 parameters
What actually differs
Parameter
LX C101-10
BC100DE
Difference
Usable energy
101.38 kWh
92.16 kWh
9.22 kWh apart
Nominal voltage
422 V
512 V
90 V apart
Weight
1120.0 kg
1500.0 kg
380.0 kg lighter
Weight per kWh
11.0 kg/kWh
16.3 kg/kWh
5.2 kg/kWh lighter
Min operating temperature
-20 °C
-30 °C
10 °C more cold tolerant
Inverter
None (battery only)
Built in (all-in-one)
None (battery only) vs Built in (all-in-one)
Ingress protection
IP21
IP54 (battery cabinet); IP65 (inverter)
IP21 vs IP54 (battery cabinet); IP65 (inverter)
Operating voltage
369.6-468.6 V
456-576 V
369.6-468.6 V vs 456-576 V
Dimensions
1650x1155x730 mm
2380x1100x1100 mm
1650x1155x730 mm vs 2380x1100x1100 mm
Shop prices by brand: See 38 GoodWe offers
02
Full specification
Parameter
LX C101-10
BC100DE
Difference
Capacity
Usable energy
101.38 kWh
92.16 kWh
9.22 kWh apart
Nominal energy
-
102.40 kWh
Not published by GoodWe
Depth of discharge
-
90 %
Not published by GoodWe
Max system capacity
156.6 kWh
-
Not published by KSTAR
Modules per stack
11-17
-
Not published by KSTAR
Power
Continuous discharge power
42.24 kW
-
Not published by KSTAR
Continuous charge power
42.24 kW
-
Not published by KSTAR
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
0.42 kW/kWh
-
Not published by KSTAR
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
-
-
Neither datasheet publishes this
Cycle test depth
100 %
-
Not published by KSTAR
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
422 V
512 V
90 V apart
Operating voltage
369.6-468.6 V
456-576 V
369.6-468.6 V vs 456-576 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
Yes
Not published by GoodWe
Built-in inverter
Inverter
None (battery only)
Built in (all-in-one)
None (battery only) vs Built in (all-in-one)
Inverter power
-
50.0 kW
Not published by GoodWe
Grid connection
-
3-phase
Not published by GoodWe
Backup power
-
50.0 kW
Not published by GoodWe
Physical
Weight
1120.0 kg
1500.0 kg
-380.0 kg for LX C101-10
Weight per kWh
11.0 kg/kWh
16.3 kg/kWh
-5.2 kg/kWh for LX C101-10
Dimensions
1650x1155x730 mm
2380x1100x1100 mm
1650x1155x730 mm vs 2380x1100x1100 mm
Ingress protection
IP21
IP54 (battery cabinet); IP65 (inverter)
IP21 vs IP54 (battery cabinet); IP65 (inverter)
Outdoor-rated
-
Yes
Not published by GoodWe
Min operating temperature
-20 °C
-30 °C
-10 °C for BC100DE
Max operating temperature
50 °C
50 °C
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
GoodWe LX C101-10 vs Deye BOS-A (15 modules in series)
10 differences, the largest is usable energy
Similar capacity
GoodWe LX C101-10 vs Huawei LUNA2000-97KWH-1H1
13 differences, the largest is usable energy
Similar capacity
GoodWe LX C101-10 vs GoodWe LX C120-10
7 differences, the largest is usable energy
Similar capacity
KSTAR BC100DE vs Deye BOS-A (11 modules in series)
11 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.