Deye BOS-G80 Pro vs Deye BOS-A (11 modules in series)
VS
The verdict
A (11 modules in series) leads on the differences that matter
The largest is usable energy: 2.30 kWh apart. 10 of 20 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
10
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 20 parameters
What actually differs
Parameter
G80 Pro
A (11 modules in series)
Difference
Usable energy
73.73 kWh
76.03 kWh
2.30 kWh apart
Max system capacity
81.9 kWh
176.6 kWh
94.7 kWh more room to expand
Nominal energy
81.92 kWh
84.48 kWh
2.56 kWh apart
Nominal voltage
819 V
422 V
397 V apart
Weight
837.0 kg
830.0 kg
7.0 kg lighter
Ingress protection
IP20 (battery enclosure)
IP20
IP20 (battery enclosure) vs IP20
Weight per kWh
11.4 kg/kWh
10.9 kg/kWh
0.4 kg/kWh lighter
Modules per stack
5-16
7-23
5-16 vs 7-23
Operating voltage
704-934.4 V
469.6-475.2 V
704-934.4 V vs 469.6-475.2 V
Dimensions
1629x1060x602 mm
1921x629x605 mm
1629x1060x602 mm vs 1921x629x605 mm
Shop prices by brand: See 44 Deye offers
02
Full specification
Parameter
G80 Pro
A (11 modules in series)
Difference
Capacity
Usable energy
73.73 kWh
76.03 kWh
2.30 kWh apart
Nominal energy
81.92 kWh
84.48 kWh
2.56 kWh apart
Depth of discharge
90 %
90 %
Same
Max system capacity
81.9 kWh
176.6 kWh
+94.7 kWh for A (11 modules in series)
Modules per stack
5-16
7-23
5-16 vs 7-23
Power
Continuous discharge power
81.92 kW
-
Not published by Deye
Continuous charge power
81.92 kW
-
Not published by Deye
Peak discharge power
102.40 kW
-
Not published by Deye
Power per kWh
1.11 kW/kWh
-
Not published by Deye
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
90 %
90 %
Same
Capacity at end of life
70 %
70 %
Same
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
819 V
422 V
397 V apart
Operating voltage
704-934.4 V
469.6-475.2 V
704-934.4 V vs 469.6-475.2 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
837.0 kg
830.0 kg
-7.0 kg for A (11 modules in series)
Weight per kWh
11.4 kg/kWh
10.9 kg/kWh
-0.4 kg/kWh for A (11 modules in series)
Dimensions
1629x1060x602 mm
1921x629x605 mm
1629x1060x602 mm vs 1921x629x605 mm
Ingress protection
IP20 (battery enclosure)
IP20
IP20 (battery enclosure) vs IP20
Outdoor-rated
-
-
Neither datasheet publishes this
Min operating temperature
-20 °C
-20 °C
Same
Max operating temperature
55 °C
55 °C
Same
Warranty
Warranty
10 yrs
10 yrs
Same
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.