Skip to main content
BOS-G80 Pro vs GE-F60-EU 5 of 18 identical Swap Change batteries

Deye BOS-G80 Pro vs Deye GE-F60-EU

Deye BOS-G80 Pro
BOS-G80 Pro
73.73 kWh LFP HV
VS
Deye GE-F60-EU
GE-F60-EU
61.4 kWh 91.0 % round-trip LFP HV
The verdict

BOS-G80 Pro leads on the differences that matter

The largest is usable energy: 12.33 kWh apart. 5 of 18 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
5 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 18 parameters
Parameter BOS-G80 Pro GE-F60-EU Difference
Usable energy 73.73 kWh 61.40 kWh 12.33 kWh apart
Continuous discharge power 81.92 kW 50.00 kW 31.92 kW more power
Nominal energy 81.92 kWh 61.40 kWh 20.52 kWh apart
Peak discharge power 102.40 kW 75.00 kW 27.40 kW more surge
Power per kWh 1.11 kW/kWh 0.81 kW/kWh 0.30 kW/kWh more power for its size
Weight 837.0 kg 1095.0 kg 258.0 kg lighter
Weight per kWh 11.4 kg/kWh 17.8 kg/kWh 6.5 kg/kWh lighter
Min operating temperature -20 °C -40 °C 20 °C more cold tolerant
Max operating temperature 55 °C 60 °C 5 °C more heat tolerant
Inverter None (battery only) Built in (all-in-one) None (battery only) vs Built in (all-in-one)
Ingress protection IP20 (battery enclosure) IP55 IP20 (battery enclosure) vs IP55
Operating voltage 704-934.4 V 500-700 V 704-934.4 V vs 500-700 V
Dimensions 1629x1060x602 mm 2235x735x1045 mm 1629x1060x602 mm vs 2235x735x1045 mm

Shop prices by brand: See 44 Deye offers

02

Full specification

Parameter BOS-G80 Pro GE-F60-EU Difference
Capacity
Usable energy 73.73 kWh 61.40 kWh 12.33 kWh apart
Nominal energy 81.92 kWh 61.40 kWh 20.52 kWh apart
Depth of discharge 90 % - Not published by Deye
Max system capacity 81.9 kWh - Not published by Deye
Modules per stack 5-16 - Not published by Deye
Power
Continuous discharge power 81.92 kW 50.00 kW +31.92 kW for BOS-G80 Pro
Continuous charge power 81.92 kW - Not published by Deye
Peak discharge power 102.40 kW 75.00 kW +27.40 kW for BOS-G80 Pro
Power per kWh 1.11 kW/kWh 0.81 kW/kWh +0.30 kW/kWh for BOS-G80 Pro
Efficiency and lifetime
Round-trip efficiency - 91.0 % Not published by Deye
Cycle life 6000 cycles 6000 cycles Same
Cycle test depth 90 % - Not published by Deye
Capacity at end of life 70 % 70 % Same
Self-discharge - - Neither datasheet publishes this
Electrical
Voltage class High voltage High voltage Same
Nominal voltage 819 V - Not published by Deye
Operating voltage 704-934.4 V 500-700 V 704-934.4 V vs 500-700 V
Cell chemistry LFP LFP Same
Active cell balancing - - Neither datasheet publishes this
Thermal management - - Neither datasheet publishes this
Built-in inverter
Inverter None (battery only) Built in (all-in-one) None (battery only) vs Built in (all-in-one)
Inverter power - 50.0 kW Not published by Deye
Grid connection - 3-phase Not published by Deye
Backup power - 50.0 kW Not published by Deye
Physical
Weight 837.0 kg 1095.0 kg -258.0 kg for BOS-G80 Pro
Weight per kWh 11.4 kg/kWh 17.8 kg/kWh -6.5 kg/kWh for BOS-G80 Pro
Dimensions 1629x1060x602 mm 2235x735x1045 mm 1629x1060x602 mm vs 2235x735x1045 mm
Ingress protection IP20 (battery enclosure) IP55 IP20 (battery enclosure) vs IP55
Outdoor-rated - - Neither datasheet publishes this
Min operating temperature -20 °C -40 °C -20 °C for GE-F60-EU
Max operating temperature 55 °C 60 °C +5 °C for GE-F60-EU
Warranty
Warranty 10 yrs 10 yrs Same
Warranted throughput - - Neither datasheet publishes this
03

More useful comparisons

Open all batteries
Similar capacity
Deye BOS-G80 Pro vs Deye BOS-A (11 modules in series)
10 differences, the largest is usable energy
Similar capacity
Deye BOS-G80 Pro vs Deye BOS-G60 Pro
9 differences, the largest is usable energy
Similar capacity
Deye BOS-G80 Pro vs KSTAR BC100DE
11 differences, the largest is usable energy
Similar capacity
Deye GE-F60-EU vs Deye BOS-G60
9 differences, the largest is usable energy
Similar capacity
Deye GE-F60-EU vs Deye BOS-G55
10 differences, the largest is usable energy
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.