Deye GE-F60-EU vs Deye BOS-G55
VS
The verdict
10 differences, and they point both ways
The largest is usable energy: 10.72 kWh apart. 5 of 15 comparable parameters are identical, with 18 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
5
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 15 parameters
What actually differs
Parameter
GE-F60-EU
BOS-G55
Difference
Usable energy
61.40 kWh
50.68 kWh
10.72 kWh apart
Nominal energy
61.40 kWh
56.32 kWh
5.08 kWh apart
Weight
1095.0 kg
610.0 kg
485.0 kg lighter
Weight per kWh
17.8 kg/kWh
12.0 kg/kWh
5.8 kg/kWh lighter
Min operating temperature
-40 °C
-20 °C
20 °C more cold tolerant
Max operating temperature
60 °C
55 °C
5 °C more heat tolerant
Inverter
Built in (all-in-one)
None (battery only)
Built in (all-in-one) vs None (battery only)
Ingress protection
IP55
IP20
IP55 vs IP20
Operating voltage
500-700 V
457.6-642.4 V
500-700 V vs 457.6-642.4 V
Dimensions
2235x735x1045 mm
2219x530x602 mm
2235x735x1045 mm vs 2219x530x602 mm
Shop prices by brand: See 44 Deye offers
02
Full specification
Parameter
GE-F60-EU
BOS-G55
Difference
Capacity
Usable energy
61.40 kWh
50.68 kWh
10.72 kWh apart
Nominal energy
61.40 kWh
56.32 kWh
5.08 kWh apart
Depth of discharge
-
90 %
Not published by Deye
Max system capacity
-
61.4 kWh
Not published by Deye
Modules per stack
-
3-12
Not published by Deye
Power
Continuous discharge power
50.00 kW
-
Not published by Deye
Continuous charge power
-
-
Neither datasheet publishes this
Peak discharge power
75.00 kW
-
Not published by Deye
Power per kWh
0.81 kW/kWh
-
Not published by Deye
Efficiency and lifetime
Round-trip efficiency
91.0 %
-
Not published by Deye
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
-
90 %
Not published by Deye
Capacity at end of life
70 %
70 %
Same
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
-
563 V
Not published by Deye
Operating voltage
500-700 V
457.6-642.4 V
500-700 V vs 457.6-642.4 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
Built in (all-in-one)
None (battery only)
Built in (all-in-one) vs None (battery only)
Inverter power
50.0 kW
-
Not published by Deye
Grid connection
3-phase
-
Not published by Deye
Backup power
50.0 kW
-
Not published by Deye
Physical
Weight
1095.0 kg
610.0 kg
-485.0 kg for BOS-G55
Weight per kWh
17.8 kg/kWh
12.0 kg/kWh
-5.8 kg/kWh for BOS-G55
Dimensions
2235x735x1045 mm
2219x530x602 mm
2235x735x1045 mm vs 2219x530x602 mm
Ingress protection
IP55
IP20
IP55 vs IP20
Outdoor-rated
-
-
Neither datasheet publishes this
Min operating temperature
-40 °C
-20 °C
-20 °C for GE-F60-EU
Max operating temperature
60 °C
55 °C
+5 °C for GE-F60-EU
Warranty
Warranty
10 yrs
10 yrs
Same
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
Deye GE-F60-EU vs Deye BOS-G60 Pro
12 differences, the largest is usable energy
Similar capacity
Deye GE-F60-EU vs Deye BOS-G60
9 differences, the largest is usable energy
Similar capacity
Deye GE-F60-EU vs Deye BOS-G80 Pro
13 differences, the largest is usable energy
Similar capacity
Deye BOS-G55 vs Deye BOS-A (7 modules in series)
9 differences, the largest is usable energy
Similar capacity
Deye BOS-G55 vs Deye BOS-G50
7 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.