Deye BOS-G55 vs Deye BOS-A (7 modules in series)
VS
The verdict
A (7 modules in series) leads on the differences that matter
The largest is usable energy: 2.30 kWh apart. 11 of 20 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
11
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 20 parameters
What actually differs
Parameter
G55
A (7 modules in series)
Difference
Usable energy
50.68 kWh
48.38 kWh
2.30 kWh apart
Max system capacity
61.4 kWh
176.6 kWh
115.2 kWh more room to expand
Nominal energy
56.32 kWh
53.76 kWh
2.56 kWh apart
Nominal voltage
563 V
269 V
294 V apart
Weight
610.0 kg
538.0 kg
72.0 kg lighter
Weight per kWh
12.0 kg/kWh
11.1 kg/kWh
0.9 kg/kWh lighter
Modules per stack
3-12
7-23
3-12 vs 7-23
Operating voltage
457.6-642.4 V
235.2-302.4 V
457.6-642.4 V vs 235.2-302.4 V
Dimensions
2219x530x602 mm
1351x629x605 mm
2219x530x602 mm vs 1351x629x605 mm
Shop prices by brand: See 44 Deye offers
02
Full specification
Parameter
G55
A (7 modules in series)
Difference
Capacity
Usable energy
50.68 kWh
48.38 kWh
2.30 kWh apart
Nominal energy
56.32 kWh
53.76 kWh
2.56 kWh apart
Depth of discharge
90 %
90 %
Same
Max system capacity
61.4 kWh
176.6 kWh
+115.2 kWh for A (7 modules in series)
Modules per stack
3-12
7-23
3-12 vs 7-23
Power
Continuous discharge power
-
-
Neither datasheet publishes this
Continuous charge power
-
-
Neither datasheet publishes this
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
-
-
Neither datasheet publishes this
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
90 %
90 %
Same
Capacity at end of life
70 %
70 %
Same
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
563 V
269 V
294 V apart
Operating voltage
457.6-642.4 V
235.2-302.4 V
457.6-642.4 V vs 235.2-302.4 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
610.0 kg
538.0 kg
-72.0 kg for A (7 modules in series)
Weight per kWh
12.0 kg/kWh
11.1 kg/kWh
-0.9 kg/kWh for A (7 modules in series)
Dimensions
2219x530x602 mm
1351x629x605 mm
2219x530x602 mm vs 1351x629x605 mm
Ingress protection
IP20
IP20
Same
Outdoor-rated
-
-
Neither datasheet publishes this
Min operating temperature
-20 °C
-20 °C
Same
Max operating temperature
55 °C
55 °C
Same
Warranty
Warranty
10 yrs
10 yrs
Same
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
Deye BOS-G55 vs Deye BOS-G50
7 differences, the largest is usable energy
Similar capacity
Deye BOS-G55 vs Deye BOS-G60
5 differences, the largest is usable energy
Similar capacity
Deye BOS-G55 vs Deye BOS-G60 Pro
9 differences, the largest is usable energy
Similar capacity
Deye BOS-A (7 modules in series) vs Deye BOS-G45
9 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.