Runergy HY-DH132H10-740 vs Runergy SS9-60HD-610M
VS
The verdict
HY-DH132H10-740 leads on the differences that matter
The largest is module efficiency: 2.25 pp more efficient. 5 of 19 comparable parameters are identical.
See all 14 differencesHow alike are they
5
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
14 of 19 parameters
What actually differs
Parameter
HY-DH132H10-740
SS9-60HD-610M
Difference
Module efficiency
23.80 %
21.55 %
2.25 pp more efficient
Temperature coefficient
-0.260 %/°C
-0.330 %/°C
0.070 %/°C better in heat
Rated power
740 Wp
610 Wp
130 W more power
Power density
238.2 Wp/m²
215.5 Wp/m²
22.7 Wp/m² higher
Weight
38.3 kg
34.5 kg
3.8 kg lighter
Open-circuit voltage
51.34 V
41.80 V
9.54 V apart
Module area
3.106 m²
2.830 m²
0.276 m² apart
Weight per kWp
51.8 kg/kWp
56.6 kg/kWp
4.8 kg/kWp lighter
Annual degradation
0.38 %/yr
0.45 %/yr
0.07 %/yr slower
Cell technology
HJT
PERC
HJT vs PERC
Voltage at max power
43.25 V
35.20 V
8.05 V apart
Cell count
132
120
12 cells apart
Short-circuit current
17.91 A
18.52 A
0.61 A apart
Dimensions
2384x1303x33 mm
2172x1303x33 mm
2384x1303x33 mm vs 2172x1303x33 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
HY-DH132H10-740
24,906 kWh
SS9-60HD-610M
20,088 kWh
Lifetime gap
4,818 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
HY-DH132H10-740
SS9-60HD-610M
Standard test conditions
25 °C
100.0% of rated power
740 W
610 W
Cool, bright day
40 °C
95.0% of rated power
711 W
580 W
Typical summer roof
55 °C
90.1% of rated power
682 W
550 W
Hot roof
70 °C
85.2% of rated power
653 W
519 W
03
Full specification
Parameter
HY-DH132H10-740
SS9-60HD-610M
Difference
Power and efficiency
Rated power
740 Wp
610 Wp
+130 W for HY-DH132H10-740
Module efficiency
23.80 %
21.55 %
+2.25 pp for HY-DH132H10-740
Power density
238.2 Wp/m²
215.5 Wp/m²
+22.7 Wp/m² for HY-DH132H10-740
Open-circuit voltage
51.34 V
41.80 V
9.54 V apart
Voltage at max power
43.25 V
35.20 V
8.05 V apart
Short-circuit current
17.91 A
18.52 A
0.61 A apart
Current at max power
17.11 A
17.36 A
Effectively the same
Temperature
Temperature coefficient
-0.260 %/°C
-0.330 %/°C
+0.070 %/°C for HY-DH132H10-740
Mechanical
Dimensions
2384x1303x33 mm
2172x1303x33 mm
2384x1303x33 mm vs 2172x1303x33 mm
Module area
3.106 m²
2.830 m²
0.276 m² apart
Weight
38.3 kg
34.5 kg
-3.8 kg for SS9-60HD-610M
Weight per kWp
51.8 kg/kWp
56.6 kg/kWp
-4.8 kg/kWp for HY-DH132H10-740
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.38 %/yr
0.45 %/yr
-0.07 %/yr for HY-DH132H10-740
Technology
Cell technology
HJT
PERC
HJT vs PERC
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
132
120
12 cells apart
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#514
vs
#7,994
HY-DH132H10-740 leads by 7,480 places
Power density
#513
vs
#7,936
HY-DH132H10-740 leads by 7,423 places
Heat behaviour
#521
vs
#8,787
HY-DH132H10-740 leads by 8,266 places
Weight
#5,221
vs
#10,953
HY-DH132H10-740 leads by 5,732 places
Warranty
#31
vs
#31
Tied - the same position in the database
Overall
#194
vs
#4,681
HY-DH132H10-740 leads by 4,487 places
05
Open the full database
More useful comparisons
Same series, other bin
Runergy
Runergy HY-DH132H10-740 vs Runergy HY-DH132H10-Plus-740
One difference: dimensions
Same series, other bin
Runergy
Runergy HY-DH132H10-740 vs Runergy HY-DH132H10-735
The same specification on paper
Same series, other bin
Runergy
Runergy HY-DH132H10-740 vs Runergy HY-DH132H10-Plus-735
One difference: dimensions
Same series, other bin
Runergy
Runergy HY-DH132H10-740 vs Runergy HY-DH132H10-730
3 differences, the largest is module efficiency
Same series, other bin
Runergy
Runergy HY-DH132H10-740 vs Runergy HY-DH132N10-730
9 differences, the largest is temperature coefficient
Same series, other bin
Runergy
Runergy HY-DH132H10-740 vs Runergy HY-DH132H10-Plus-730
4 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Runergy HY-DH132H10-740 or Runergy SS9-60HD-610M?
According to our database: Runergy HY-DH132H10-740 has higher module efficiency (23.80% vs 21.55%); Runergy HY-DH132H10-740 tolerates heat better (temp coeff -0.260%/°C vs -0.330%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Runergy HY-DH132H10-740 and Runergy SS9-60HD-610M?
Runergy HY-DH132H10-740 has a module efficiency of 23.80%, while Runergy SS9-60HD-610M is 21.55%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Runergy HY-DH132H10-740 use vs Runergy SS9-60HD-610M?
Runergy HY-DH132H10-740 uses HJT cells; Runergy SS9-60HD-610M uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Runergy HY-DH132H10-740 and Runergy SS9-60HD-610M?
Runergy HY-DH132H10-740 has a 30 years power warranty; Runergy SS9-60HD-610M has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Runergy HY-DH132H10-740 and Runergy SS9-60HD-610M bifacial panels?
Both Runergy HY-DH132H10-740 and Runergy SS9-60HD-610M are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 5 Runergy offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.