Skip to main content
S6-EO1P4K-48 vs SPF 4000TL HVM 6 of 16 identical Swap Change inverters

Ginlong Solis S6-EO1P4K-48 vs Growatt SPF 4000TL HVM

Ginlong Solis S6-EO1P4K-48
Ginlong Solis
S6-EO1P4K-48
4 kW Off-grid
VS
Growatt SPF 4000TL HVM
Growatt
SPF 4000TL HVM
4 kW Off-grid
The verdict

S6-EO1P4K-48 leads on the differences that matter

The largest is max dc voltage: 355 V apart. 6 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
6 of 16 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 16 parameters
Parameter S6-EO1P4K-48 SPF 4000TL HVM Difference
Max DC voltage 500 V 145 V 355 V apart
Max efficiency 96.6 % 93.0 % 3.6 pp more efficient
Max PV power 5.50 kW 4.50 kW 1.00 kW apart
DC/AC ratio 1.38 1.12 0.25 more oversizing headroom
Weight 13.8 kg 11.0 kg 2.8 kg lighter
Weight per kW 3.5 kg/kW 2.8 kg/kW 0.7 kg/kW lighter
Max operating temperature 60 °C 55 °C 5 °C more heat tolerant
MPPT voltage range 90-430 V 30-115 V 90-430 V vs 30-115 V
Battery voltage 40 - 60 V 24VDC or 48VDC (model-dependent) 40 - 60 V vs 24VDC or 48VDC (model-dependent)
Dimensions 480x340x170 mm 455x350x130 mm 480x340x170 mm vs 455x350x130 mm
02

Full specification

Parameter S6-EO1P4K-48 SPF 4000TL HVM Difference
AC output
Rated AC power 4.00 kW 4.00 kW Same
Max AC power 4.00 kW 4.00 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 20.0 A - Not published by Growatt
PV input
Max PV power 5.50 kW 4.50 kW 1.00 kW apart
DC/AC ratio 1.38 1.12 +0.25 for S6-EO1P4K-48
Max DC voltage 500 V 145 V 355 V apart
MPPT voltage range 90-430 V 30-115 V 90-430 V vs 30-115 V
Start voltage 90 V - Not published by Growatt
MPP trackers 1 - Not published by Growatt
Strings per tracker 2 - Not published by Growatt
Max input current per tracker 16.0 A - Not published by Growatt
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 96.6 % 93.0 % +3.6 pp for S6-EO1P4K-48
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 40 - 60 V 24VDC or 48VDC (model-dependent) 40 - 60 V vs 24VDC or 48VDC (model-dependent)
Max charge current 100 A - Not published by Growatt
Backup power - - Neither datasheet publishes this
Physical
Weight 13.8 kg 11.0 kg -2.8 kg for SPF 4000TL HVM
Weight per kW 3.5 kg/kW 2.8 kg/kW -0.7 kg/kW for SPF 4000TL HVM
Dimensions 480x340x170 mm 455x350x130 mm 480x340x170 mm vs 455x350x130 mm
Ingress protection IP21 - Not published by Growatt
Cooling - - Neither datasheet publishes this
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 55 °C +5 °C for S6-EO1P4K-48
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Growatt
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Ginlong Solis S6-EO1P4K-48 vs Growatt SPF 4000T DVM
12 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-EO1P4K-48 vs Growatt SPF 4000T DVM-MPV
11 differences, the largest is max dc voltage
Same type, similar size
Easun Power
Ginlong Solis S6-EO1P4K-48 vs Easun Power ISolar SPL 5K
5 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.