Skip to main content
SPF 4000TL HVM vs S6-EO1P4K-48 6 of 16 identical Swap Change inverters

Growatt SPF 4000TL HVM vs Ginlong Solis S6-EO1P4K-48

Growatt SPF 4000TL HVM
Growatt
SPF 4000TL HVM
4 kW Off-grid
VS
Ginlong Solis S6-EO1P4K-48
Ginlong Solis
S6-EO1P4K-48
4 kW Off-grid
The verdict

S6-EO1P4K-48 leads on the differences that matter

The largest is max dc voltage: 355 V apart. 6 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
6 of 16 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 16 parameters
Parameter SPF 4000TL HVM S6-EO1P4K-48 Difference
Max DC voltage 145 V 500 V 355 V apart
Max efficiency 93.0 % 96.6 % 3.6 pp more efficient
Max PV power 4.50 kW 5.50 kW 1.00 kW apart
DC/AC ratio 1.12 1.38 0.25 more oversizing headroom
Weight 11.0 kg 13.8 kg 2.8 kg lighter
Weight per kW 2.8 kg/kW 3.5 kg/kW 0.7 kg/kW lighter
Max operating temperature 55 °C 60 °C 5 °C more heat tolerant
MPPT voltage range 30-115 V 90-430 V 30-115 V vs 90-430 V
Battery voltage 24VDC or 48VDC (model-dependent) 40 - 60 V 24VDC or 48VDC (model-dependent) vs 40 - 60 V
Dimensions 455x350x130 mm 480x340x170 mm 455x350x130 mm vs 480x340x170 mm
02

Full specification

Parameter SPF 4000TL HVM S6-EO1P4K-48 Difference
AC output
Rated AC power 4.00 kW 4.00 kW Same
Max AC power 4.00 kW 4.00 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current - 20.0 A Not published by Growatt
PV input
Max PV power 4.50 kW 5.50 kW 1.00 kW apart
DC/AC ratio 1.12 1.38 +0.25 for S6-EO1P4K-48
Max DC voltage 145 V 500 V 355 V apart
MPPT voltage range 30-115 V 90-430 V 30-115 V vs 90-430 V
Start voltage - 90 V Not published by Growatt
MPP trackers - 1 Not published by Growatt
Strings per tracker - 2 Not published by Growatt
Max input current per tracker - 16.0 A Not published by Growatt
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 93.0 % 96.6 % +3.6 pp for S6-EO1P4K-48
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 24VDC or 48VDC (model-dependent) 40 - 60 V 24VDC or 48VDC (model-dependent) vs 40 - 60 V
Max charge current - 100 A Not published by Growatt
Backup power - - Neither datasheet publishes this
Physical
Weight 11.0 kg 13.8 kg -2.8 kg for SPF 4000TL HVM
Weight per kW 2.8 kg/kW 3.5 kg/kW -0.7 kg/kW for SPF 4000TL HVM
Dimensions 455x350x130 mm 480x340x170 mm 455x350x130 mm vs 480x340x170 mm
Ingress protection - IP21 Not published by Growatt
Cooling - - Neither datasheet publishes this
Noise - - Neither datasheet publishes this
Max operating temperature 55 °C 60 °C +5 °C for S6-EO1P4K-48
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Growatt
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt SPF 4000TL HVM vs Growatt SPF 4000T DVM
10 differences, the largest is max efficiency
Same type, similar size
Growatt
Growatt SPF 4000TL HVM vs Growatt SPF 4000T DVM-MPV
10 differences, the largest is max dc voltage
Same type, similar size
Easun Power
Growatt SPF 4000TL HVM vs Easun Power ISolar SPL 5K
3 differences, the largest is weight
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.