Skip to main content
4000TL HVM vs 4000T DVM 6 of 16 identical Swap Change inverters

Growatt SPF 4000TL HVM vs Growatt SPF 4000T DVM

Growatt SPF 4000TL HVM
Growatt
SPF 4000TL HVM
4 kW Off-grid
VS
Growatt SPF 4000T DVM
Growatt
SPF 4000T DVM
4 kW Off-grid
The verdict

10 differences, and they point both ways

The largest is max efficiency: 5.0 pp more efficient. 6 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
6 of 16 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 16 parameters
Parameter 4000TL HVM 4000T DVM Difference
Max efficiency 93.0 % 98.0 % 5.0 pp more efficient
Max PV power 4.50 kW 5.00 kW 0.50 kW apart
Weight 11.0 kg 42.0 kg 31.0 kg lighter
Weight per kW 2.8 kg/kW 10.5 kg/kW 7.8 kg/kW lighter
DC/AC ratio 1.12 1.25 0.12 more oversizing headroom
Max operating temperature 55 °C 45 °C 10 °C more heat tolerant
Nominal AC voltage 230 V 240 V 10 V apart
MPPT voltage range 30-115 V 60-145 V 30-115 V vs 60-145 V
Battery voltage 24VDC or 48VDC (model-dependent) 48VDC 24VDC or 48VDC (model-dependent) vs 48VDC
Dimensions 455x350x130 mm 540x360x218 mm 455x350x130 mm vs 540x360x218 mm
02

Full specification

Parameter 4000TL HVM 4000T DVM Difference
AC output
Rated AC power 4.00 kW 4.00 kW Same
Max AC power 4.00 kW 4.00 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 240 V 10 V apart
Max AC current - - Neither datasheet publishes this
PV input
Max PV power 4.50 kW 5.00 kW 0.50 kW apart
DC/AC ratio 1.12 1.25 +0.12 for 4000T DVM
Max DC voltage 145 V 150 V Effectively the same
MPPT voltage range 30-115 V 60-145 V 30-115 V vs 60-145 V
Start voltage - - Neither datasheet publishes this
MPP trackers - - Neither datasheet publishes this
Strings per tracker - - Neither datasheet publishes this
Max input current per tracker - - Neither datasheet publishes this
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 93.0 % 98.0 % +5.0 pp for 4000T DVM
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 24VDC or 48VDC (model-dependent) 48VDC 24VDC or 48VDC (model-dependent) vs 48VDC
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 11.0 kg 42.0 kg -31.0 kg for 4000TL HVM
Weight per kW 2.8 kg/kW 10.5 kg/kW -7.8 kg/kW for 4000TL HVM
Dimensions 455x350x130 mm 540x360x218 mm 455x350x130 mm vs 540x360x218 mm
Ingress protection - IP20 Not published by Growatt
Cooling - - Neither datasheet publishes this
Noise - - Neither datasheet publishes this
Max operating temperature 55 °C 45 °C +10 °C for 4000TL HVM
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt SPF 4000TL HVM vs Growatt SPF 4000T DVM-MPV
10 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt SPF 4000TL HVM vs Ginlong Solis S6-EO1P4K-48
10 differences, the largest is max dc voltage
Same type, similar size
Easun Power
Growatt SPF 4000TL HVM vs Easun Power ISolar SPL 5K
3 differences, the largest is weight
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.