Skip to main content
S6-EO1P4K-48 vs SPF 4000T DVM-MPV 3 of 14 identical Swap Change inverters

Ginlong Solis S6-EO1P4K-48 vs Growatt SPF 4000T DVM-MPV

Ginlong Solis S6-EO1P4K-48
Ginlong Solis
S6-EO1P4K-48
4 kW Off-grid
VS
Growatt SPF 4000T DVM-MPV
Growatt
SPF 4000T DVM-MPV
4 kW Off-grid
The verdict

S6-EO1P4K-48 leads on the differences that matter

The largest is max dc voltage: 250 V apart. 3 of 14 comparable parameters are identical, with 18 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
3 of 14 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 14 parameters
Parameter S6-EO1P4K-48 SPF 4000T DVM-MPV Difference
Max DC voltage 500 V 250 V 250 V apart
Max efficiency 96.6 % 85.0 % 11.6 pp more efficient
Max PV power 5.50 kW 5.00 kW 0.50 kW apart
Weight 13.8 kg 42.0 kg 28.2 kg lighter
Weight per kW 3.5 kg/kW 10.5 kg/kW 7.0 kg/kW lighter
DC/AC ratio 1.38 1.25 0.12 more oversizing headroom
Max operating temperature 60 °C 45 °C 15 °C more heat tolerant
Ingress protection IP21 IP20 IP21 vs IP20
Nominal AC voltage 230 V 240 V 10 V apart
MPPT voltage range 90-430 V 60-245 V 90-430 V vs 60-245 V
Dimensions 480x340x170 mm 540x360x218 mm 480x340x170 mm vs 540x360x218 mm
02

Full specification

Parameter S6-EO1P4K-48 SPF 4000T DVM-MPV Difference
AC output
Rated AC power 4.00 kW 4.00 kW Same
Max AC power 4.00 kW 4.00 kW Same
Grid connection Single-phase - Not published by Growatt
Nominal AC voltage 230 V 240 V 10 V apart
Max AC current 20.0 A - Not published by Growatt
PV input
Max PV power 5.50 kW 5.00 kW 0.50 kW apart
DC/AC ratio 1.38 1.25 +0.12 for S6-EO1P4K-48
Max DC voltage 500 V 250 V 250 V apart
MPPT voltage range 90-430 V 60-245 V 90-430 V vs 60-245 V
Start voltage 90 V - Not published by Growatt
MPP trackers 1 - Not published by Growatt
Strings per tracker 2 - Not published by Growatt
Max input current per tracker 16.0 A - Not published by Growatt
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 96.6 % 85.0 % +11.6 pp for S6-EO1P4K-48
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 40 - 60 V - Not published by Growatt
Max charge current 100 A - Not published by Growatt
Backup power - - Neither datasheet publishes this
Physical
Weight 13.8 kg 42.0 kg -28.2 kg for S6-EO1P4K-48
Weight per kW 3.5 kg/kW 10.5 kg/kW -7.0 kg/kW for S6-EO1P4K-48
Dimensions 480x340x170 mm 540x360x218 mm 480x340x170 mm vs 540x360x218 mm
Ingress protection IP21 IP20 IP21 vs IP20
Cooling - - Neither datasheet publishes this
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 45 °C +15 °C for S6-EO1P4K-48
Connectivity and safety
Wi-Fi Yes - Not published by Growatt
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Growatt
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Ginlong Solis S6-EO1P4K-48 vs Growatt SPF 4000T DVM
12 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-EO1P4K-48 vs Growatt SPF 4000TL HVM
10 differences, the largest is max dc voltage
Same type, similar size
Easun Power
Ginlong Solis S6-EO1P4K-48 vs Easun Power ISolar SPL 5K
5 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.