SPF 4000T DVM-MPV vs S6-EO1P4K-48 3 of 14 identical Swap Change inverters

Growatt SPF 4000T DVM-MPV vs Ginlong Solis S6-EO1P4K-48

Growatt SPF 4000T DVM-MPV
Growatt
SPF 4000T DVM-MPV
4 kW Off-grid
VS
Ginlong Solis S6-EO1P4K-48
Ginlong Solis
S6-EO1P4K-48
4 kW Off-grid
The verdict

S6-EO1P4K-48 leads on the differences that matter

The largest is max dc voltage: 250 V apart. 3 of 14 comparable parameters are identical, with 18 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
3 of 14 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 14 parameters
Parameter SPF 4000T DVM-MPV S6-EO1P4K-48 Difference
Max DC voltage 250 V 500 V 250 V apart
Max efficiency 85.0 % 96.6 % 11.6 pp more efficient
Max PV power 5.00 kW 5.50 kW 0.50 kW apart
Weight 42.0 kg 13.8 kg 28.2 kg lighter
Weight per kW 10.5 kg/kW 3.5 kg/kW 7.0 kg/kW lighter
DC/AC ratio 1.25 1.38 0.12 more oversizing headroom
Max operating temperature 45 °C 60 °C 15 °C more heat tolerant
Ingress protection IP20 IP21 IP20 vs IP21
Nominal AC voltage 240 V 230 V 10 V apart
MPPT voltage range 60-245 V 90-430 V 60-245 V vs 90-430 V
Dimensions 540x360x218 mm 480x340x170 mm 540x360x218 mm vs 480x340x170 mm
02

Full specification

Parameter SPF 4000T DVM-MPV S6-EO1P4K-48 Difference
AC output
Rated AC power 4.00 kW 4.00 kW Same
Max AC power 4.00 kW 4.00 kW Same
Grid connection - Single-phase Not published by Growatt
Nominal AC voltage 240 V 230 V 10 V apart
Max AC current - 20.0 A Not published by Growatt
PV input
Max PV power 5.00 kW 5.50 kW 0.50 kW apart
DC/AC ratio 1.25 1.38 +0.12 for S6-EO1P4K-48
Max DC voltage 250 V 500 V 250 V apart
MPPT voltage range 60-245 V 90-430 V 60-245 V vs 90-430 V
Start voltage - 90 V Not published by Growatt
MPP trackers - 1 Not published by Growatt
Strings per tracker - 2 Not published by Growatt
Max input current per tracker - 16.0 A Not published by Growatt
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 85.0 % 96.6 % +11.6 pp for S6-EO1P4K-48
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage - 40 - 60 V Not published by Growatt
Max charge current - 100 A Not published by Growatt
Backup power - - Neither datasheet publishes this
Physical
Weight 42.0 kg 13.8 kg -28.2 kg for S6-EO1P4K-48
Weight per kW 10.5 kg/kW 3.5 kg/kW -7.0 kg/kW for S6-EO1P4K-48
Dimensions 540x360x218 mm 480x340x170 mm 540x360x218 mm vs 480x340x170 mm
Ingress protection IP20 IP21 IP20 vs IP21
Cooling - - Neither datasheet publishes this
Noise - - Neither datasheet publishes this
Max operating temperature 45 °C 60 °C +15 °C for S6-EO1P4K-48
Connectivity and safety
Wi-Fi - Yes Not published by Growatt
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Growatt
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt SPF 4000T DVM-MPV vs Growatt SPF 4000T DVM
3 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPF 4000T DVM-MPV vs Growatt SPF 4000TL HVM
10 differences, the largest is max dc voltage
Same type, similar size
Easun Power
Growatt SPF 4000T DVM-MPV vs Easun Power ISolar SPL 5K
6 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.