Ginlong Solis S6-EO1P4K-48 vs Growatt SPF 4000T DVM
VS
The verdict
S6-EO1P4K-48 leads on the differences that matter
The largest is max dc voltage: 350 V apart. 5 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
5
of 17 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 17 parameters
What actually differs
Parameter
S6-EO1P4K-48
SPF 4000T DVM
Difference
Max DC voltage
500 V
150 V
350 V apart
Max efficiency
96.6 %
98.0 %
1.4 pp more efficient
Max PV power
5.50 kW
5.00 kW
0.50 kW apart
Weight
13.8 kg
42.0 kg
28.2 kg lighter
Weight per kW
3.5 kg/kW
10.5 kg/kW
7.0 kg/kW lighter
DC/AC ratio
1.38
1.25
0.12 more oversizing headroom
Max operating temperature
60 °C
45 °C
15 °C more heat tolerant
Ingress protection
IP21
IP20
IP21 vs IP20
Nominal AC voltage
230 V
240 V
10 V apart
MPPT voltage range
90-430 V
60-145 V
90-430 V vs 60-145 V
Battery voltage
40 - 60 V
48VDC
40 - 60 V vs 48VDC
Dimensions
480x340x170 mm
540x360x218 mm
480x340x170 mm vs 540x360x218 mm
02
Full specification
Parameter
S6-EO1P4K-48
SPF 4000T DVM
Difference
AC output
Rated AC power
4.00 kW
4.00 kW
Same
Max AC power
4.00 kW
4.00 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
240 V
10 V apart
Max AC current
20.0 A
-
Not published by Growatt
PV input
Max PV power
5.50 kW
5.00 kW
0.50 kW apart
DC/AC ratio
1.38
1.25
+0.12 for S6-EO1P4K-48
Max DC voltage
500 V
150 V
350 V apart
MPPT voltage range
90-430 V
60-145 V
90-430 V vs 60-145 V
Start voltage
90 V
-
Not published by Growatt
MPP trackers
1
-
Not published by Growatt
Strings per tracker
2
-
Not published by Growatt
Max input current per tracker
16.0 A
-
Not published by Growatt
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
96.6 %
98.0 %
+1.4 pp for SPF 4000T DVM
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
40 - 60 V
48VDC
40 - 60 V vs 48VDC
Max charge current
100 A
-
Not published by Growatt
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
13.8 kg
42.0 kg
-28.2 kg for S6-EO1P4K-48
Weight per kW
3.5 kg/kW
10.5 kg/kW
-7.0 kg/kW for S6-EO1P4K-48
Dimensions
480x340x170 mm
540x360x218 mm
480x340x170 mm vs 540x360x218 mm
Ingress protection
IP21
IP20
IP21 vs IP20
Cooling
-
-
Neither datasheet publishes this
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
45 °C
+15 °C for S6-EO1P4K-48
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Ginlong Solis S6-EO1P4K-48 vs Growatt SPF 4000T DVM-MPV
11 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-EO1P4K-48 vs Growatt SPF 4000TL HVM
10 differences, the largest is max dc voltage
Same type, similar size
Easun Power
Ginlong Solis S6-EO1P4K-48 vs Easun Power ISolar SPL 5K
5 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.