SPF 4000T DVM vs S6-EO1P4K-48 5 of 17 identical Swap Change inverters

Growatt SPF 4000T DVM vs Ginlong Solis S6-EO1P4K-48

Growatt SPF 4000T DVM
Growatt
SPF 4000T DVM
4 kW Off-grid
VS
Ginlong Solis S6-EO1P4K-48
Ginlong Solis
S6-EO1P4K-48
4 kW Off-grid
The verdict

S6-EO1P4K-48 leads on the differences that matter

The largest is max dc voltage: 350 V apart. 5 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
5 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 17 parameters
Parameter SPF 4000T DVM S6-EO1P4K-48 Difference
Max DC voltage 150 V 500 V 350 V apart
Max efficiency 98.0 % 96.6 % 1.4 pp more efficient
Max PV power 5.00 kW 5.50 kW 0.50 kW apart
Weight 42.0 kg 13.8 kg 28.2 kg lighter
Weight per kW 10.5 kg/kW 3.5 kg/kW 7.0 kg/kW lighter
DC/AC ratio 1.25 1.38 0.12 more oversizing headroom
Max operating temperature 45 °C 60 °C 15 °C more heat tolerant
Ingress protection IP20 IP21 IP20 vs IP21
Nominal AC voltage 240 V 230 V 10 V apart
MPPT voltage range 60-145 V 90-430 V 60-145 V vs 90-430 V
Battery voltage 48VDC 40 - 60 V 48VDC vs 40 - 60 V
Dimensions 540x360x218 mm 480x340x170 mm 540x360x218 mm vs 480x340x170 mm
02

Full specification

Parameter SPF 4000T DVM S6-EO1P4K-48 Difference
AC output
Rated AC power 4.00 kW 4.00 kW Same
Max AC power 4.00 kW 4.00 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 240 V 230 V 10 V apart
Max AC current - 20.0 A Not published by Growatt
PV input
Max PV power 5.00 kW 5.50 kW 0.50 kW apart
DC/AC ratio 1.25 1.38 +0.12 for S6-EO1P4K-48
Max DC voltage 150 V 500 V 350 V apart
MPPT voltage range 60-145 V 90-430 V 60-145 V vs 90-430 V
Start voltage - 90 V Not published by Growatt
MPP trackers - 1 Not published by Growatt
Strings per tracker - 2 Not published by Growatt
Max input current per tracker - 16.0 A Not published by Growatt
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 98.0 % 96.6 % +1.4 pp for SPF 4000T DVM
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 48VDC 40 - 60 V 48VDC vs 40 - 60 V
Max charge current - 100 A Not published by Growatt
Backup power - - Neither datasheet publishes this
Physical
Weight 42.0 kg 13.8 kg -28.2 kg for S6-EO1P4K-48
Weight per kW 10.5 kg/kW 3.5 kg/kW -7.0 kg/kW for S6-EO1P4K-48
Dimensions 540x360x218 mm 480x340x170 mm 540x360x218 mm vs 480x340x170 mm
Ingress protection IP20 IP21 IP20 vs IP21
Cooling - - Neither datasheet publishes this
Noise - - Neither datasheet publishes this
Max operating temperature 45 °C 60 °C +15 °C for S6-EO1P4K-48
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Growatt
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt SPF 4000T DVM vs Growatt SPF 4000T DVM-MPV
3 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPF 4000T DVM vs Growatt SPF 4000TL HVM
10 differences, the largest is max efficiency
Same type, similar size
Easun Power
Growatt SPF 4000T DVM vs Easun Power ISolar SPL 5K
6 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.