FoxESS ECS2900-H4 vs Dyness Tower T10
VS
The verdict
ECS2900-H4 leads on the differences that matter
The largest is usable energy: 0.29 kWh apart. 3 of 14 comparable parameters are identical, with 19 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
3
of 14 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 14 parameters
What actually differs
Parameter
ECS2900-H4
Tower T10
Difference
Usable energy
10.37 kWh
10.66 kWh
0.29 kWh apart
Nominal energy
11.52 kWh
10.66 kWh
0.86 kWh apart
Depth of discharge
90 %
100 %
10 pp more of the cells usable
Nominal voltage
230 V
288 V
58 V apart
Weight
132.3 kg
146.0 kg
13.7 kg lighter
Min operating temperature
-20 °C
-10 °C
10 °C more cold tolerant
Weight per kWh
12.8 kg/kWh
13.7 kg/kWh
0.9 kg/kWh lighter
Max operating temperature
55 °C
50 °C
5 °C more heat tolerant
Ingress protection
IP65
IP54
IP65 vs IP54
Modules per stack
2-7
2-6
2-7 vs 2-6
Dimensions
590x570x380 mm
900x504x380 mm
590x570x380 mm vs 900x504x380 mm
02
1 shop we track
Price offers
Shop
ECS2900-H4
Tower T10
At this shop
Shop prices by brand: See 21 FoxESS offers · See 20 Dyness offers
03
Full specification
Parameter
ECS2900-H4
Tower T10
Difference
Capacity
Usable energy
10.37 kWh
10.66 kWh
0.29 kWh apart
Nominal energy
11.52 kWh
10.66 kWh
0.86 kWh apart
Depth of discharge
90 %
100 %
+10 pp for Tower T10
Max system capacity
20.2 kWh
-
Not published by Dyness
Modules per stack
2-7
2-6
2-7 vs 2-6
Power
Continuous discharge power
-
6.39 kW
Not published by FoxESS
Continuous charge power
-
6.39 kW
Not published by FoxESS
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
-
0.60 kW/kWh
Not published by FoxESS
Efficiency and lifetime
Round-trip efficiency
95.0 %
-
Not published by Dyness
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
90 %
-
Not published by Dyness
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
230 V
288 V
58 V apart
Operating voltage
194.4-262.8 V
-
Not published by Dyness
Cell chemistry
LFP
-
Not published by Dyness
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
132.3 kg
146.0 kg
-13.7 kg for ECS2900-H4
Weight per kWh
12.8 kg/kWh
13.7 kg/kWh
-0.9 kg/kWh for ECS2900-H4
Dimensions
590x570x380 mm
900x504x380 mm
590x570x380 mm vs 900x504x380 mm
Ingress protection
IP65
IP54
IP65 vs IP54
Outdoor-rated
Yes
-
Not published by Dyness
Min operating temperature
-20 °C
-10 °C
-10 °C for ECS2900-H4
Max operating temperature
55 °C
50 °C
+5 °C for ECS2900-H4
Warranty
Warranty
-
10 yrs
Not published by FoxESS
Warranted throughput
-
-
Neither datasheet publishes this
04
Open all batteries
More useful comparisons
Similar capacity
FoxESS ECS2900-H4 vs BYD Battery-Box Premium HVS 10.2
15 differences, the largest is usable energy
Similar capacity
FoxESS ECS2900-H4 vs Huawei LUNA2000-10-S0
11 differences, the largest is usable energy
Similar capacity
FoxESS ECS2900-H4 vs SMA Home Storage 9.8
15 differences, the largest is usable energy
Similar capacity
Dyness Tower T10 vs Dyness Tower Pro TP11
14 differences, the largest is usable energy
Similar capacity
Dyness Tower T10 vs BYD Battery-Box Premium HVM 11.0
4 differences, the largest is usable energy
Similar capacity
Dyness Tower T10 vs Deye GB-L12
13 differences, the largest is usable energy
05
Written summary
Checking cache...