Skip to main content
ECS2900-H4 vs Tower T10 3 of 14 identical Swap Change batteries

FoxESS ECS2900-H4 vs Dyness Tower T10

FoxESS ECS2900-H4
ECS2900-H4
10.37 kWh 95.0 % round-trip LFP HV
VS
Tower T10
10.66 kWh HV
The verdict

ECS2900-H4 leads on the differences that matter

The largest is usable energy: 0.29 kWh apart. 3 of 14 comparable parameters are identical, with 19 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
3 of 14 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 14 parameters
Parameter ECS2900-H4 Tower T10 Difference
Usable energy 10.37 kWh 10.66 kWh 0.29 kWh apart
Nominal energy 11.52 kWh 10.66 kWh 0.86 kWh apart
Depth of discharge 90 % 100 % 10 pp more of the cells usable
Nominal voltage 230 V 288 V 58 V apart
Weight 132.3 kg 146.0 kg 13.7 kg lighter
Min operating temperature -20 °C -10 °C 10 °C more cold tolerant
Weight per kWh 12.8 kg/kWh 13.7 kg/kWh 0.9 kg/kWh lighter
Max operating temperature 55 °C 50 °C 5 °C more heat tolerant
Ingress protection IP65 IP54 IP65 vs IP54
Modules per stack 2-7 2-6 2-7 vs 2-6
Dimensions 590x570x380 mm 900x504x380 mm 590x570x380 mm vs 900x504x380 mm
02

Price offers

1 shop we track
Shop ECS2900-H4 Tower T10 At this shop
solarboss.ie Ireland - 6 199.20 € incl. VAT Only Tower T10

All 1 offer for Tower T10

Shop prices by brand: See 21 FoxESS offers · See 20 Dyness offers

03

Full specification

Parameter ECS2900-H4 Tower T10 Difference
Capacity
Usable energy 10.37 kWh 10.66 kWh 0.29 kWh apart
Nominal energy 11.52 kWh 10.66 kWh 0.86 kWh apart
Depth of discharge 90 % 100 % +10 pp for Tower T10
Max system capacity 20.2 kWh - Not published by Dyness
Modules per stack 2-7 2-6 2-7 vs 2-6
Power
Continuous discharge power - 6.39 kW Not published by FoxESS
Continuous charge power - 6.39 kW Not published by FoxESS
Peak discharge power - - Neither datasheet publishes this
Power per kWh - 0.60 kW/kWh Not published by FoxESS
Efficiency and lifetime
Round-trip efficiency 95.0 % - Not published by Dyness
Cycle life 6000 cycles 6000 cycles Same
Cycle test depth 90 % - Not published by Dyness
Capacity at end of life - - Neither datasheet publishes this
Self-discharge - - Neither datasheet publishes this
Electrical
Voltage class High voltage High voltage Same
Nominal voltage 230 V 288 V 58 V apart
Operating voltage 194.4-262.8 V - Not published by Dyness
Cell chemistry LFP - Not published by Dyness
Active cell balancing - - Neither datasheet publishes this
Thermal management - - Neither datasheet publishes this
Built-in inverter
Inverter None (battery only) None (battery only) Same
Inverter power - - Neither datasheet publishes this
Grid connection - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 132.3 kg 146.0 kg -13.7 kg for ECS2900-H4
Weight per kWh 12.8 kg/kWh 13.7 kg/kWh -0.9 kg/kWh for ECS2900-H4
Dimensions 590x570x380 mm 900x504x380 mm 590x570x380 mm vs 900x504x380 mm
Ingress protection IP65 IP54 IP65 vs IP54
Outdoor-rated Yes - Not published by Dyness
Min operating temperature -20 °C -10 °C -10 °C for ECS2900-H4
Max operating temperature 55 °C 50 °C +5 °C for ECS2900-H4
Warranty
Warranty - 10 yrs Not published by FoxESS
Warranted throughput - - Neither datasheet publishes this
04

More useful comparisons

Open all batteries
Similar capacity
FoxESS ECS2900-H4 vs BYD Battery-Box Premium HVS 10.2
15 differences, the largest is usable energy
Similar capacity
FoxESS ECS2900-H4 vs Huawei LUNA2000-10-S0
11 differences, the largest is usable energy
Similar capacity
FoxESS ECS2900-H4 vs SMA Home Storage 9.8
15 differences, the largest is usable energy
Similar capacity
Dyness Tower T10 vs Dyness Tower Pro TP11
14 differences, the largest is usable energy
Similar capacity
Dyness Tower T10 vs BYD Battery-Box Premium HVM 11.0
4 differences, the largest is usable energy
Similar capacity
Dyness Tower T10 vs Deye GB-L12
13 differences, the largest is usable energy