Dyness Tower T7 vs Solplanet Ai-HB 075A
VS
The verdict
13 differences, and they point both ways
The largest is usable energy: 0.19 kWh apart. 4 of 17 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
4
of 17 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 17 parameters
What actually differs
Parameter
Tower T7
Ai-HB 075A
Difference
Usable energy
7.10 kWh
6.91 kWh
0.19 kWh apart
Continuous discharge power
4.26 kW
4.61 kW
0.35 kW more power
Nominal energy
7.10 kWh
7.68 kWh
0.58 kWh apart
Depth of discharge
100 %
90 %
10 pp more of the cells usable
Continuous charge power
4.26 kW
3.84 kW
0.42 kW faster charging
Nominal voltage
192 V
154 V
38 V apart
Min operating temperature
-10 °C
-20 °C
10 °C more cold tolerant
Weight
105.0 kg
106.5 kg
1.5 kg lighter
Weight per kWh
14.8 kg/kWh
15.4 kg/kWh
0.6 kg/kWh lighter
Ingress protection
IP54
IP65
IP54 vs IP65
Power per kWh
0.60 kW/kWh
0.67 kW/kWh
0.07 kW/kWh more power for its size
Modules per stack
2-6
3-8
2-6 vs 3-8
Dimensions
700x504x380 mm
600x540x390 mm
700x504x380 mm vs 600x540x390 mm
Shop prices by brand: See 20 Dyness offers · See 4 Solplanet offers
02
Full specification
Parameter
Tower T7
Ai-HB 075A
Difference
Capacity
Usable energy
7.10 kWh
6.91 kWh
0.19 kWh apart
Nominal energy
7.10 kWh
7.68 kWh
0.58 kWh apart
Depth of discharge
100 %
90 %
+10 pp for Tower T7
Max system capacity
-
20.5 kWh
Not published by Dyness
Modules per stack
2-6
3-8
2-6 vs 3-8
Power
Continuous discharge power
4.26 kW
4.61 kW
+0.35 kW for Ai-HB 075A
Continuous charge power
4.26 kW
3.84 kW
+0.42 kW for Tower T7
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
0.60 kW/kWh
0.67 kW/kWh
+0.07 kW/kWh for Ai-HB 075A
Efficiency and lifetime
Round-trip efficiency
-
95.0 %
Not published by Dyness
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
-
80 %
Not published by Dyness
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
192 V
154 V
38 V apart
Operating voltage
-
120-175.2 V
Not published by Dyness
Cell chemistry
-
LFP
Not published by Dyness
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
105.0 kg
106.5 kg
-1.5 kg for Tower T7
Weight per kWh
14.8 kg/kWh
15.4 kg/kWh
-0.6 kg/kWh for Tower T7
Dimensions
700x504x380 mm
600x540x390 mm
700x504x380 mm vs 600x540x390 mm
Ingress protection
IP54
IP65
IP54 vs IP65
Outdoor-rated
-
Yes
Not published by Dyness
Min operating temperature
-10 °C
-20 °C
-10 °C for Ai-HB 075A
Max operating temperature
50 °C
50 °C
Same
Warranty
Warranty
10 yrs
-
Not published by Solplanet
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
Dyness Tower T7 vs FoxESS HS7.5
6 differences, the largest is nominal energy
Similar capacity
Dyness Tower T7 vs Dyness Tower Pro TP7
14 differences, the largest is usable energy
Similar capacity
Dyness Tower T7 vs Deye GB-L8
13 differences, the largest is usable energy
Similar capacity
Solplanet Ai-HB 075A vs SMA Home Storage 6.5
17 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.