Skip to main content
Tower T14 vs Ai-HB 150A 4 of 17 identical Swap Change batteries

Dyness Tower T14 vs Solplanet Ai-HB 150A

Tower T14
14.21 kWh HV
VS
Solplanet Ai-HB 150A
Ai-HB 150A
13.82 kWh 95.0 % round-trip LFP HV
The verdict

13 differences, and they point both ways

The largest is usable energy: 0.39 kWh apart. 4 of 17 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
4 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 17 parameters
Parameter Tower T14 Ai-HB 150A Difference
Usable energy 14.21 kWh 13.82 kWh 0.39 kWh apart
Continuous discharge power 8.52 kW 9.22 kW 0.70 kW more power
Nominal energy 14.21 kWh 15.36 kWh 1.15 kWh apart
Depth of discharge 100 % 90 % 10 pp more of the cells usable
Continuous charge power 8.52 kW 7.68 kW 0.84 kW faster charging
Nominal voltage 384 V 307 V 77 V apart
Weight 187.0 kg 198.0 kg 11.0 kg lighter
Min operating temperature -10 °C -20 °C 10 °C more cold tolerant
Weight per kWh 13.2 kg/kWh 14.3 kg/kWh 1.2 kg/kWh lighter
Ingress protection IP54 IP65 IP54 vs IP65
Power per kWh 0.60 kW/kWh 0.67 kW/kWh 0.07 kW/kWh more power for its size
Modules per stack 2-6 3-8 2-6 vs 3-8
Dimensions 1100x504x380 mm 990x540x390 mm 1100x504x380 mm vs 990x540x390 mm

Shop prices by brand: See 20 Dyness offers · See 4 Solplanet offers

02

Full specification

Parameter Tower T14 Ai-HB 150A Difference
Capacity
Usable energy 14.21 kWh 13.82 kWh 0.39 kWh apart
Nominal energy 14.21 kWh 15.36 kWh 1.15 kWh apart
Depth of discharge 100 % 90 % +10 pp for Tower T14
Max system capacity - 20.5 kWh Not published by Dyness
Modules per stack 2-6 3-8 2-6 vs 3-8
Power
Continuous discharge power 8.52 kW 9.22 kW +0.70 kW for Ai-HB 150A
Continuous charge power 8.52 kW 7.68 kW +0.84 kW for Tower T14
Peak discharge power - - Neither datasheet publishes this
Power per kWh 0.60 kW/kWh 0.67 kW/kWh +0.07 kW/kWh for Ai-HB 150A
Efficiency and lifetime
Round-trip efficiency - 95.0 % Not published by Dyness
Cycle life 6000 cycles 6000 cycles Same
Cycle test depth - 80 % Not published by Dyness
Capacity at end of life - - Neither datasheet publishes this
Self-discharge - - Neither datasheet publishes this
Electrical
Voltage class High voltage High voltage Same
Nominal voltage 384 V 307 V 77 V apart
Operating voltage - 240-350.4 V Not published by Dyness
Cell chemistry - LFP Not published by Dyness
Active cell balancing - - Neither datasheet publishes this
Thermal management - - Neither datasheet publishes this
Built-in inverter
Inverter None (battery only) None (battery only) Same
Inverter power - - Neither datasheet publishes this
Grid connection - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 187.0 kg 198.0 kg -11.0 kg for Tower T14
Weight per kWh 13.2 kg/kWh 14.3 kg/kWh -1.2 kg/kWh for Tower T14
Dimensions 1100x504x380 mm 990x540x390 mm 1100x504x380 mm vs 990x540x390 mm
Ingress protection IP54 IP65 IP54 vs IP65
Outdoor-rated - Yes Not published by Dyness
Min operating temperature -10 °C -20 °C -10 °C for Ai-HB 150A
Max operating temperature 50 °C 50 °C Same
Warranty
Warranty 10 yrs - Not published by Solplanet
Warranted throughput - - Neither datasheet publishes this
03

More useful comparisons

Open all batteries
Similar capacity
Dyness Tower T14 vs FoxESS HS15
6 differences, the largest is nominal energy
Similar capacity
Dyness Tower T14 vs Dyness Tower Pro TP15
14 differences, the largest is usable energy
Similar capacity
Dyness Tower T14 vs Deye BOS-G15
11 differences, the largest is usable energy
Similar capacity
Solplanet Ai-HB 150A vs BYD Battery-Box Premium HVM 13.8
7 differences, the largest is max system capacity
Similar capacity
Solplanet Ai-HB 150A vs Huawei LUNA2000-14-S1
13 differences, the largest is continuous discharge power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.