Dyness Tower T14 vs FoxESS HS15
VS
The verdict
HS15 leads on the differences that matter
The largest is nominal energy: 0.53 kWh apart. 5 of 11 comparable parameters are identical, with 22 more left out because at least one datasheet does not publish them.
See all 6 differencesHow alike are they
5
of 11 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
6 of 11 parameters
What actually differs
Parameter
Tower T14
HS15
Difference
Nominal energy
14.21 kWh
14.74 kWh
0.53 kWh apart
Nominal voltage
384 V
307 V
77 V apart
Usable energy
14.21 kWh
14.29 kWh
0.08 kWh apart
Max operating temperature
50 °C
55 °C
5 °C more heat tolerant
Ingress protection
IP54
IP21
IP54 vs IP21
Modules per stack
2-6
2-8
2-6 vs 2-8
Shop prices by brand: See 20 Dyness offers · See 21 FoxESS offers
02
Full specification
Parameter
Tower T14
HS15
Difference
Capacity
Usable energy
14.21 kWh
14.29 kWh
0.08 kWh apart
Nominal energy
14.21 kWh
14.74 kWh
0.53 kWh apart
Depth of discharge
100 %
-
Not published by FoxESS
Max system capacity
-
19.6 kWh
Not published by Dyness
Modules per stack
2-6
2-8
2-6 vs 2-8
Power
Continuous discharge power
8.52 kW
-
Not published by FoxESS
Continuous charge power
8.52 kW
-
Not published by FoxESS
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
0.60 kW/kWh
-
Not published by FoxESS
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
-
80 %
Not published by Dyness
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
384 V
307 V
77 V apart
Operating voltage
-
259.2-350.4 V
Not published by Dyness
Cell chemistry
-
LFP
Not published by Dyness
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
187.0 kg
-
Not published by FoxESS
Weight per kWh
13.2 kg/kWh
-
Not published by FoxESS
Dimensions
1100x504x380 mm
-
Not published by FoxESS
Ingress protection
IP54
IP21
IP54 vs IP21
Outdoor-rated
-
-
Neither datasheet publishes this
Min operating temperature
-10 °C
-10 °C
Same
Max operating temperature
50 °C
55 °C
+5 °C for HS15
Warranty
Warranty
10 yrs
10 yrs
Same
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
Dyness Tower T14 vs Dyness Tower Pro TP15
14 differences, the largest is usable energy
Similar capacity
Dyness Tower T14 vs Solplanet Ai-HB 150A
13 differences, the largest is usable energy
Similar capacity
Dyness Tower T14 vs Deye BOS-G15
11 differences, the largest is usable energy
Similar capacity
FoxESS HS15 vs Deye GB-L16
9 differences, the largest is usable energy
Similar capacity
FoxESS HS15 vs Deye GB-SL-EU (4 modules in series)
11 differences, the largest is usable energy
04