Dyness Tower Pro TP7 vs Dyness Tower T7
VS
The verdict
Tower Pro TP7 leads on the differences that matter
The largest is usable energy: 0.20 kWh apart. 4 of 18 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
4
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 18 parameters
What actually differs
Parameter
Tower Pro TP7
Tower T7
Difference
Usable energy
7.30 kWh
7.10 kWh
0.20 kWh apart
Continuous discharge power
7.68 kW
4.26 kW
3.42 kW more power
Cycle life
8000 cycles
6000 cycles
2000 cycles more
Warranty
15 yrs
10 yrs
5 yrs longer
Nominal energy
7.68 kWh
7.10 kWh
0.58 kWh apart
Depth of discharge
95 %
100 %
5 pp more of the cells usable
Continuous charge power
7.68 kW
4.26 kW
3.42 kW faster charging
Power per kWh
1.05 kW/kWh
0.60 kW/kWh
0.45 kW/kWh more power for its size
Weight
99.5 kg
105.0 kg
5.5 kg lighter
Min operating temperature
-20 °C
-10 °C
10 °C more cold tolerant
Weight per kWh
13.6 kg/kWh
14.8 kg/kWh
1.2 kg/kWh lighter
Max operating temperature
55 °C
50 °C
5 °C more heat tolerant
Ingress protection
IP55
IP54
IP55 vs IP54
Dimensions
788x587x310 mm
700x504x380 mm
788x587x310 mm vs 700x504x380 mm
02
1 shop we track
Price offers
Shop
Tower Pro TP7
Tower T7
At this shop
Shop prices by brand: See 26 Dyness offers
03
Full specification
Parameter
Tower Pro TP7
Tower T7
Difference
Capacity
Usable energy
7.30 kWh
7.10 kWh
0.20 kWh apart
Nominal energy
7.68 kWh
7.10 kWh
0.58 kWh apart
Depth of discharge
95 %
100 %
+5 pp for Tower T7
Max system capacity
23.0 kWh
-
Not published by Dyness
Modules per stack
2-6
2-6
Same
Power
Continuous discharge power
7.68 kW
4.26 kW
+3.42 kW for Tower Pro TP7
Continuous charge power
7.68 kW
4.26 kW
+3.42 kW for Tower Pro TP7
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
1.05 kW/kWh
0.60 kW/kWh
+0.45 kW/kWh for Tower Pro TP7
Efficiency and lifetime
Round-trip efficiency
95.0 %
-
Not published by Dyness
Cycle life
8000 cycles
6000 cycles
+2000 cycles for Tower Pro TP7
Cycle test depth
95 %
-
Not published by Dyness
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
192 V
192 V
Same
Operating voltage
168-219 V
-
Not published by Dyness
Cell chemistry
LFP
-
Not published by Dyness
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
99.5 kg
105.0 kg
-5.5 kg for Tower Pro TP7
Weight per kWh
13.6 kg/kWh
14.8 kg/kWh
-1.2 kg/kWh for Tower Pro TP7
Dimensions
788x587x310 mm
700x504x380 mm
788x587x310 mm vs 700x504x380 mm
Ingress protection
IP55
IP54
IP55 vs IP54
Outdoor-rated
Yes
-
Not published by Dyness
Min operating temperature
-20 °C
-10 °C
-10 °C for Tower Pro TP7
Max operating temperature
55 °C
50 °C
+5 °C for Tower Pro TP7
Warranty
Warranty
15 yrs
10 yrs
+5 yrs for Tower Pro TP7
Warranted throughput
-
-
Neither datasheet publishes this
04
Open all batteries
More useful comparisons
Similar capacity
Dyness Tower Pro TP7 vs Deye GB-L8
16 differences, the largest is continuous discharge power
Similar capacity
Dyness Tower Pro TP7 vs Deye GB-SL-EU (2 modules in series)
15 differences, the largest is cycle life
Similar capacity
Dyness Tower Pro TP7 vs FoxESS HS7.5
11 differences, the largest is cycle life
Similar capacity
Dyness Tower T7 vs Solplanet Ai-HB 075A
13 differences, the largest is usable energy
05
Written summary
Checking cache...