Skip to main content
BOS-G20 vs Tower Pro TP19 5 of 19 identical Swap Change batteries

Deye BOS-G20 vs Dyness Tower Pro TP19

Deye BOS-G20
BOS-G20
18.43 kWh LFP HV
VS
Dyness Tower Pro TP19
Tower Pro TP19
18.24 kWh 95.0 % round-trip LFP HV
The verdict

Tower Pro TP19 leads on the differences that matter

The largest is usable energy: 0.19 kWh apart. 5 of 19 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
5 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 19 parameters
Parameter BOS-G20 Tower Pro TP19 Difference
Usable energy 18.43 kWh 18.24 kWh 0.19 kWh apart
Cycle life 6000 cycles 8000 cycles 2000 cycles more
Warranty 10 yrs 15 yrs 5 yrs longer
Max system capacity 61.4 kWh 23.0 kWh 38.4 kWh more room to expand
Nominal energy 20.48 kWh 19.20 kWh 1.28 kWh apart
Depth of discharge 90 % 95 % 5 pp more of the cells usable
Nominal voltage 205 V 480 V 275 V apart
Weight 420.0 kg 206.0 kg 214.0 kg lighter
Weight per kWh 22.8 kg/kWh 11.3 kg/kWh 11.5 kg/kWh lighter
Cycle test depth 90 % 95 % 5 pp apart
Ingress protection IP20 IP55 IP20 vs IP55
Modules per stack 3-12 2-6 3-12 vs 2-6
Operating voltage 166.4-233.6 V 420-547 V 166.4-233.6 V vs 420-547 V
Dimensions 1629x530x602 mm 1451x587x310 mm 1629x530x602 mm vs 1451x587x310 mm
02

Price offers

1 shop we track
Shop BOS-G20 Tower Pro TP19 At this shop
Sklep Soltech Poland - 15 806.56 zł net Only Tower Pro TP19

All 1 offer for Tower Pro TP19

Shop prices by brand: See 46 Deye offers · See 26 Dyness offers

03

Full specification

Parameter BOS-G20 Tower Pro TP19 Difference
Capacity
Usable energy 18.43 kWh 18.24 kWh 0.19 kWh apart
Nominal energy 20.48 kWh 19.20 kWh 1.28 kWh apart
Depth of discharge 90 % 95 % +5 pp for Tower Pro TP19
Max system capacity 61.4 kWh 23.0 kWh +38.4 kWh for BOS-G20
Modules per stack 3-12 2-6 3-12 vs 2-6
Power
Continuous discharge power - 19.20 kW Not published by Deye
Continuous charge power - 19.20 kW Not published by Deye
Peak discharge power - - Neither datasheet publishes this
Power per kWh - 1.05 kW/kWh Not published by Deye
Efficiency and lifetime
Round-trip efficiency - 95.0 % Not published by Deye
Cycle life 6000 cycles 8000 cycles +2000 cycles for Tower Pro TP19
Cycle test depth 90 % 95 % 5 pp apart
Capacity at end of life 70 % - Not published by Dyness
Self-discharge - - Neither datasheet publishes this
Electrical
Voltage class High voltage High voltage Same
Nominal voltage 205 V 480 V 275 V apart
Operating voltage 166.4-233.6 V 420-547 V 166.4-233.6 V vs 420-547 V
Cell chemistry LFP LFP Same
Active cell balancing - - Neither datasheet publishes this
Thermal management - - Neither datasheet publishes this
Built-in inverter
Inverter None (battery only) None (battery only) Same
Inverter power - - Neither datasheet publishes this
Grid connection - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 420.0 kg 206.0 kg -214.0 kg for Tower Pro TP19
Weight per kWh 22.8 kg/kWh 11.3 kg/kWh -11.5 kg/kWh for Tower Pro TP19
Dimensions 1629x530x602 mm 1451x587x310 mm 1629x530x602 mm vs 1451x587x310 mm
Ingress protection IP20 IP55 IP20 vs IP55
Outdoor-rated - Yes Not published by Deye
Min operating temperature -20 °C -20 °C Same
Max operating temperature 55 °C 55 °C Same
Warranty
Warranty 10 yrs 15 yrs +5 yrs for Tower Pro TP19
Warranted throughput - - Neither datasheet publishes this
04

More useful comparisons

Open all batteries
Similar capacity
Deye BOS-G20 vs Solplanet Ai-HB 200A
10 differences, the largest is max system capacity
Similar capacity
Deye BOS-G20 vs Deye GB-L20
9 differences, the largest is max system capacity
Similar capacity
Deye BOS-G20 vs Deye GB-SL-EU (5 modules in series)
10 differences, the largest is max system capacity
Similar capacity
Dyness Tower Pro TP19 vs FoxESS ECS2900-H7
13 differences, the largest is cycle life
05

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.