Strong in heat, needs the roof space
The Horay Solar HS 210-108 TC-D Galaxy panel series introduces a new level of quality thanks to the use of advanced N-type TOPCon technology, which effectively eliminates the problem of light-induced degradation and ensures higher efficiency in low light conditions. The use of large 210 mm cells in a compact 108-cell format allows for powerful power output per square meter, making these modules an ideal choice for the roofs of single-family houses with limited space. The unique bifacial design combined with double glass architecture ensures that Galaxy panels not only generate energy from both sides but are also exceptionally resistant to micro-cracks and harsh weather conditions. This solves the problem of performance decline over time and gives investors the confidence of long-term, trouble-free operation. This product stands out from the competition with an excellent temperature coefficient, which translates into stable electricity production even on hot days. It is a solution dedicated to professional installations where maximizing return on investment and modern design are key. Thanks to its construction, this series provides the highest level of fire safety, which is crucial in both the residential and commercial sectors.
Ranking
Signals from the data
Hot roofs and southern climates.
Roofs where every square metre has to count, weight-limited structures and tight roof space.
Top 5% of the TOPCon 550-600 W segment, against a median of -0.290. Ranked 1,347th in the whole database.
Bottom 11% of the TOPCon 550-600 W segment, against a median of 224.4.
Bottom 12% of the TOPCon 550-600 W segment, against a median of 53.8.
Bottom 14% of the TOPCon 550-600 W segment, against a median of 22.44%.
The Galaxy series achieves 21.5-21.7% module efficiency, outperforming all three peer comparables: Boviet VEGA Series (21.3%), ET Solar Elite PLUS (21.4%), and matching JA Solar DEEP BLUE 3.0 (21.5%). Higher power density per m² is critical for residential rooftop installations with limited available area.
N-type TOPCon cells eliminate light-induced degradation (LID), a known weakness of P-type PERC. Typical TOPCon temperature coefficient of approx. -0.30%/°C vs. -0.35%/°C for PERC translates to roughly 1.75% higher output at 35°C above STC, a meaningful advantage during peak summer generation hours.
The bifacial dual-glass architecture captures an additional 10-25% energy from ground albedo reflection depending on surface type. Dual-glass construction eliminates microcracks and substantially reduces moisture ingress and PID risk - both critical for meeting the 30-year performance horizon.
Horay Solar provides a 30-year linear power warranty, exceeding the 25-year standard offered by peer-comparable products (JA Solar DEEP BLUE 3.0, ET Solar Elite PLUS). The company has maintained BNEF Tier 1 bankable manufacturer status since Q1 2025, confirmed again in Q1 2026, satisfying lender and project finance requirements.
The equipment warranty covers only 15 years, compared to the 25-year product warranty offered as standard by JA Solar (DEEP BLUE 3.0) and Trina Solar in the premium segment. For commercial installations financed via lease or project loans, the shorter warranty period may restrict available financing instruments or require supplemental insurance coverage.
With ~2.5 GW/year production capacity and a relatively short track record in European markets, Horay Solar's service infrastructure lags behind JA Solar (50+ GW, EU service offices) and Trina Solar. In markets like Poland, the availability of authorized service partners and response times for field replacements beyond year 10-15 carry measurable long-term O&M risk.
- At 21.7% efficiency, this panel is 0.7pp below the TOPCon 550-600W median of 22.4%
- At 216.8 W/m², this panel generates 7.6 W/m² less per unit area than TOPCon 550-600W median (224.4 W/m²)
- At -0.28%/°C, hot weather performance is typical for TOPCon 550-600W panels
- Bifaciality factor of 80% can add 4-12% extra yield with reflective mounting surface
- #7485 for efficiency, #1347 for temperature performance out of 14129 panels
Specifications
Datasheet charts
Measured curves published by Horay Solar in this model's datasheet. A chart carrying a wattage was measured on that variant alone - only the ones that describe 555 Wp appear here. The rest cover the whole series.
Simulations
Degradation from this panel's own datasheet figures. No inverter, soiling or shading losses.
Model: bifaciality × albedo × 0.6 view factor. A first-order estimate, not a yield simulation.
Alternatives
Found 31 panels of the same or similar size to this one, within ±10 mm. See them here Found 41 panels of the same or similar size to this one, within ±25 mm. See them here Found 41 panels of the same or similar size to this one, within ±50 mm. See them here Found 85 panels of the same or similar size to this one, within ±100 mm. See them here
About the HS 210-108 TC-D Galaxy series
These answers cover the whole series. Where a figure differs, the specification above is this module's own.