Skip to main content

AE Solar AE ME-120-580

580 Wp TOPCon
ComparePV verdict

Middle of its segment, needs the roof space

Rank 3,019 of 14,129
Compare panels Datasheet PDF
Power (Wp)
580
Typical for its class
Efficiency (%)
20.52
Weak · bottom 1%
Density (Wp/m²)
205.2
Weak · bottom 1%
Temp (%/°C)
-0.340
Weak · bottom 5%
Weight (kg)
29.0
Typical · median 31.2 kg
Warranty (yrs)
30
Typical · median 30 yrs

The Aurora ME-120 series is an advanced solution based on Gallium-doped cell technology, which effectively eliminates the problem of light-induced degradation (LID). Thanks to this, the modules maintain the highest performance for decades, providing a key advantage over standard silicon components. The use of Half-Cut Cells design allows for better system performance in partial shading conditions and a reduction of resistive losses within the panel. For the investor, this means more stable energy yields even in less favorable weather. These panels stand out for their exceptional resistance to extreme mechanical loads, making them an ideal choice for Polish climatic conditions, characterized by strong winds and heavy snow. Aurora ME-120 is a solution for demanding residential and commercial users seeking maximum reliability and an aesthetic installation appearance. The use of innovative materials makes the modules resistant to salt corrosion and ammonia, extending their application to coastal areas and farms. By choosing this series, you are investing in system longevity and energy security based on proven German engineering, which sets standards in durability and quality of workmanship.

Ranking

1,022 panels in the segment TOPCon 550-600 W
Metric This panel Median Position in segment Overall rank
Module efficiency 20.52% 22.44% Weak · bottom 1% 11,325
Power density 205.2 224.4 Weak · bottom 1% 11,331
Temperature coefficient -0.340 -0.290 Weak · bottom 5% 8,846
Weight per kWp 50.0 53.8 Typical 3,329
Performance warranty 30 yrs 30 yrs Typical 21
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Signals from the data

5 positive · 6 caution
Best for

Residential, commercial, utility-scale and shaded-installations.

Not ideal for

Roofs where every square metre has to count, tight roof space and hot climates.

Watch-outs
205.2 watts per square metre

Bottom 1% of the TOPCon 550-600 W segment, against a median of 224.4. Ranked 11,331st in the whole database.

20.52% module efficiency

Bottom 1% of the TOPCon 550-600 W segment, against a median of 22.44%. Ranked 11,325th in the whole database.

-0.340 %/°C temperature coefficient

Bottom 5% of the TOPCon 550-600 W segment, against a median of -0.290. Ranked 8,846th in the whole database.

What owners get
The only European Tier 1 brand with high creditworthiness

According to the BNEF 2024 report, AE Solar is the only European manufacturer with a high bankability rating (increasing from 26% in 2023 to 50% in 2024), which makes it easier to secure project financing and reduces the credit risk for institutional investors.

30-year warranty on the product and its performance

The manufacturer offers a full 30-year warranty, both for the product and for its power output, while the industry standard offered by comparable suppliers (e.g., Trina Solar, JA Solar) is 25 years. The extended warranty directly reduces the project's risk over the long term.

Gallium-doped electrodes - no LID degradation

Replacing boron with gallium eliminates light-induced degradation (LID), which is typical for standard PERC cells. The module maintains its specified power output from the very beginning, without the characteristic performance drop in the first year of operation that is associated with boron.

Kiwa PVEL Top Performer Award 2025

Independent laboratory tests conducted by Kiwa PVEL awarded the Aurora series the "Top Performer" title for 2025, confirming the quality and reliability of the product, as well as the accuracy of its specifications compared to those listed in the product datasheet.

Resistance to salt and ammonia corrosion

Certified compliance with IEC 61701 (salt spray) and IEC 62716 (ammonia) allows for installation in coastal areas and agricultural settings without the risk of accelerated enclosure and cell degradation.

Trade-offs
Performance is noticeably lower than that of TOPCon competitors.

The maximum efficiency of the series is 21.23%, while direct competitors in the same power range achieve 23.2% (Tongwei TWMND N-type) and 23.23% (Lexron TOPCon). This means that approximately 9% more module surface area is required to achieve the same installed power.

PERC - a technology nearing obsolescence

Market forecasts indicate a decline in the share of PERC technology at a CAGR of -10.8% between 2025 and 2030, with TOPCon technology expected to dominate (60% share by 2030). The choice of PERC in 2026 could limit the long-term viability of installations, and the higher annual degradation rate (0.6-0.8%/year vs 0.4-0.5%/year for TOPCon) would result in significant revenue losses over a 30-year period.

Lack of bifaciality

The panel is monofacial, while the competitor, Tongwei TWMND, in the same 580-600 W range offers bifacial N-type modules. When installed over a reflective surface (gravel, snow, white membrane), bifacial modules generate an additional 10-20% of energy without increasing the occupied surface area.

Notes from the database
  • Module efficiency of 20.5% is 1.9pp below average for TOPCon 550-600W panels (median: 22.4%)
  • 205.2 W/m² power density is 19.2 W/m² below TOPCon 550-600W median (224.4 W/m²) - requires larger installation area
  • Temperature coefficient of -0.34%/°C is 0.05pp worse than TOPCon 550-600W median (-0.29%/°C) - higher losses in summer heat
  • Weight of 29.0 kg (2.2 kg below TOPCon 550-600W median of 31.2 kg) allows easier transport and roof mounting
  • Ranked #11325 out of 14129 panels for efficiency in the database

Specifications

Open datasheet PDF
Nominal power (Pmax) 580 Wp Nameplate at 1000 W/m², 25 °C
Module efficiency 20.52 % Weak Segment median 22.44%
Vmpp · Impp 33.60 V · 17.26 A Operating point at max power
Voc · Isc 40.70 V · 18.25 A Sizes the string length
Max system voltage 1500 V Longer strings than 1000 V modules
Dimensions 2171×1302×30 mm · 2.83 m² of roof
Weight 29.0 kg Typical Typical · median 31.2 kg
Cells 120 · TOPCon Monocrystalline
Coefficient Pmax -0.340 %/°C Weak bottom 5% of its segment
Coefficient Voc · Isc -0.250 · 0.040 %/°C
NOCT 43 °C At 800 W/m², 20 °C ambient
Product warranty 30 years Hardware defects only
Performance warranty 30 years Typical median 30 yrs · median 30 yrs
End-of-warranty output 81.5 % Equals 473 W guaranteed
Degradation 2.50 → 0.55 % First year, then annual

Datasheet charts

Open datasheet PDF

Measured curves published by AE Solar in this model's datasheet. A chart carrying a wattage was measured on that variant alone - only the ones that describe 580 Wp appear here. The rest cover the whole series.

Simulations

Live - change any input
Lifetime output & value
30 years at 1200 kWh/kWp/year and €0.50 per kWh
Power in year 30
-
Lifetime energy
-
Energy value
-

Degradation from this panel's own datasheet figures. No inverter, soiling or shading losses.

Heat losses
-0.340 %/°C against a segment median of -0.290
-
Filter these
Size
Panel Power Eff. Temp. Weight Difference
AE Solar AE ME-120-580 580 W 20.52% -0.340 29.0 kg You are here
LR7-60HVH-560M 560 W 24.80% -0.260 25.0 kg Cooler, lighter, +4.3 pp
LR7-60HVH-555M 555 W 24.60% -0.260 25.0 kg Cooler, lighter, +4.1 pp
AIKO-A630-MAH72Dw 630 W 24.40% -0.260 32.5 kg +50 W, cooler, +3.9 pp
LR7-60HVHL-550M 550 W 24.40% -0.260 16.3 kg Cooler, lighter, +3.9 pp
JAT60S40-540/LR 540 W 24.40% -0.260 23.5 kg Cooler, lighter, +3.9 pp
AE ME-120 585 585 W 20.70% -0.340 29.0 kg Very close match
GKA210N120 680 W 24.03% -0.340 28.0 kg +100 W, lighter, +3.5 pp
GKA210N120-675 675 W 23.85% -0.340 28.0 kg +95 W, lighter, +3.3 pp
QN-670HJT-01 670 W 23.70% -0.240 35.5 kg +90 W, cooler, +3.2 pp
GKA210N120-670 670 W 23.67% -0.340 28.0 kg +90 W, lighter, +3.2 pp
QN-665HJT-01 665 W 23.50% -0.240 35.5 kg +85 W, cooler, +3.0 pp
GKA210N120-665 665 W 23.50% -0.340 28.0 kg +85 W, lighter, +3.0 pp
SPDG660-N120M12 660 W 23.32% -0.300 34.2 kg +80 W, heavier, +2.8 pp
NS-660MH-120 660 W 23.32% -0.290 31.0 kg +80 W, cooler, +2.8 pp
GKA210N120-660 660 W 23.32% -0.340 28.0 kg +80 W, lighter, +2.8 pp

Found 497 panels of the same or similar size to this one, within ±10 mm. See them here Found 502 panels of the same or similar size to this one, within ±25 mm. See them here Found 502 panels of the same or similar size to this one, within ±50 mm. See them here Found 502 panels of the same or similar size to this one, within ±100 mm. See them here

About the AURORA ME-120 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this module's own.

What is the warranty for AE Solar AURORA ME-120 solar panels?
The AURORA ME-120 series comes with a 30-year product warranty and a 30-year performance warranty on power output. This means that for three decades, the manufacturer guarantees the module's performance at the level specified in the documentation. This is one of the longest warranty packages available on the market, reflecting AE Solar's confidence in the durability of its own components.
What is the gallium-doping technology used in AURORA ME-120 panels, and does it actually prevent LID degradation?
Gallium-doped wafers replace traditional boron in the silicon structure, eliminating the light-induced degradation mechanism (LID). Standard PERC modules can lose up to 2-3% of their power in the first few weeks due to LID. In the AURORA ME-120, this problem is virtually non-existent, resulting in higher and more stable energy production from day one throughout the entire lifespan of the installation.
Will AE Solar AURORA ME-120 panels perform adequately under partial shading, for example, from a chimney or tree?
Yes. The use of Half-Cut Cell technology (120 cells cut in half) means that each cell operates at a lower current, and the panel is divided into independent electrical sections. The shading on one part of the module does not block the operation of the other cells as much as in traditional designs. For a roof with obstructions, this means a realistically higher energy yield per year.
Will the AURORA ME-120 modules withstand Polish winters, characterized by heavy snowfall and strong winds?
The AURORA ME-120 series is designed for extreme mechanical loads. The panels undergo tests exceeding European standards for snow and wind loads, making them suitable for Polish climatic conditions. The robust aluminum frame and tempered front glass provide resistance to both accumulated snow and strong winds typical of Polish winters.
Are AE Solar AURORA ME-120 panels suitable for a property located by the sea or near livestock farms?
Yes. The AURORA ME-120 modules have been proven to be resistant to salt mist and ammonia, which is a requirement of the IEC standards. This makes them suitable for use in coastal areas exposed to salt mist, as well as in the vicinity of livestock buildings, where ammonia vapors can accelerate the degradation of standard panels.
What is the maximum power output of the AE Solar AURORA ME-120 panel, and what roof area does a single module occupy?
The peak power of the module is 600 Wp, with an efficiency exceeding 21%. The dimensions of a single panel are approximately 2171 × 1302 mm, and its weight is approximately 30.5 kg. Therefore, to achieve a 10 kWp system, approximately 17 modules are needed, covering a total area of approximately 48 m² of roof space. This is a compact solution for roofs with limited usable area.
Add to compare