A close run between ten modules

JW-HD132N-705W delivers 18,550 kWh over 30 years at 0.47 c/kWh, which makes its energy 6% cheaper per kilowatt-hour than the dearest module in this report. It is not the cheapest sticker price in the set - €73.44 is - and it still wins.

6 November 2026, 11:22 a0dceed5-6e5f Saved - link stays live
Download PDF
Best long-term value
Jolywood JW-HD132N-705W 705 Wp
  • Runs cooler under load. -0.28 %/°C against -0.29 %/°C, worth 0.2 points of output at 47 °C.
  • Best composite in the set. It scores highest across lifetime energy, cost per kWh and warranty length taken together, even though it is not the cheapest energy in the set.
66 of 100
Cost per kWh 0.47 c/kWh
Ranking leader
JW-HD132N-705W
Score 66 of 100
Highest 30-year yield
18,945 kWh
2,763 kWh above the lowest module
Lowest cost per kWh
0.45 c/kWh
9% cheaper than the dearest
Modules compared
10
Prices entered by the requester
Assumptions Cell temperature47 °C InstallationGround mount Baseline yield1,000 kWh/kWp Horizon30 years CurrencyEUR Change and re-run
01

Side by side

# Manufacturer / model Power Price Year 1 30-year Cost per kWh Score
1 Jolywood JW-HD132N-705W 705 Wp €86.32 655 18,550 0.47 c/kWh 66
2 TWMNF-66HD720 720 Wp €92.98 669 18,945 0.49 c/kWh Most energy produced 60
3 JAM66D46-710/LB 710 Wp €92.57 658 18,638 0.50 c/kWh 54
4 Jolywood JW-HD156N-R0-640 640 Wp €77.81 595 16,840 0.46 c/kWh 47
5 TCL Zhonghuan HSM-ND66-GR615 615 Wp €73.44 571 16,182 0.45 c/kWh Cheapest energy in the set 42
6 JKM620N-66HL4M-BDV 620 Wp €75.01 575 16,276 0.46 c/kWh 41
7 TCL Zhonghuan HSM-ND66-GR620 620 Wp €75.62 576 16,314 0.46 c/kWh 40
8 JAM66D45-630/LB 630 Wp €79 584 16,538 0.48 c/kWh 37
9 JAM72D42-650/LB 650 Wp €84.81 602 17,063 0.50 c/kWh 35
10 JKM640N-66HL4M-BDV 640 Wp €83.12 593 16,801 0.49 c/kWh Weakest of the set 33
top 25% middle 50% bottom 25% Bands are relative to the modules in this report.

What drives each score

Each bar is the module's own composite, split into the three weighted parts that make it up. A dimension the whole set ties on separates nothing and splits evenly, and one they nearly tie on counts for nearly nothing.

JW-HD132N-705W 66
TWMNF-66HD720 60
JAM66D46-710/LB 54
JW-HD156N-R0-640 47
HSM-ND66-GR615 42
JKM620N-66HL4M-BDV 41
HSM-ND66-GR620 40
JAM66D45-630/LB 37
JAM72D42-650/LB 35
JKM640N-66HL4M-BDV 33
30-year yield · 45%Cost per kWh · 40%Warranty · 15%
02

Where the difference comes from

Cumulative energy

Kilowatt-hours added up year by year. The gap widens with every year - by year 30 it is 2,763 kWh between the highest and lowest module.

Power remaining

Percentage of nameplate power still delivered. These modules publish the same curve, so the lines overlap - the difference between them is in what that percentage is a percentage of.

03

Method

Full methodology
How each figure is built
1 Annual yield Panel watts times the installation baseline of 1,000 kWh/kWp, times a temperature factor from the module's own coefficient at 47 °C, times whatever degradation has left that year.
2 Degradation Each module ages at its own datasheet rate - JW-HD132N-705W loses 1% in year one, then 0.4% a year. Where a manufacturer publishes no curve, the 2% / 0.55% convention is used.
3 Cost per kWh Offer price divided by the thirty annual yields added together. The only figure that lets a dearer module win, and often it does.
4 Score A 0-100 composite: lifetime energy 45%, cost per kWh 40%, warranty 15%, each normalised across this report's modules. A dimension they all tie on splits evenly.
What this does not model

Energy price inflation, inverter and installation cost, local irradiance and weather, shading, or degradation behaviour that differs from the datasheet curve. This report compares modules against each other, not a full system business case. Talk to an installer before you buy.

Sources
Panel specifications read from manufacturer datasheets, refreshed daily.
Prices entered by whoever generated this report - not quotes we obtained or verified.
Baseline yield from the installation type, overridable with PVGIS data.
Generated by ComparePV on 6 November 2026, 11:22 · report a0dceed5-6e5f · anonymous and shareable Run a new comparison