Skip to main content

Solectria PVI 60KW

60 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
60.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
-
Not published
Max DC (V)
600
Weak · bottom 1%
Weight (kg)
694.0
Weak · 619.0 kg above median
Warranty (yrs)
5
Typical · median 5 yrs

The PVI KW series is Solectria's family of three-phase commercial inverters, built to serve installations ranging from tens of kilowatts up to multi-megawatt solar farms. What sets it apart is its transformer isolation, which delivers added galvanic safety and stable operation under difficult grid conditions, along with voltage flexibility that lets the unit match local electrical infrastructure (208/240/480/600 VAC). Integrated AC and DC disconnects reduce the number of additional BoS components, shortening installation time and lowering project costs. The inverters support advanced grid support functions such as active/reactive power control, voltage and frequency ride-through, and remote curtailment, making it easier to coordinate with utilities on larger projects. Thanks to MODBUS communication and a built-in cellular modem, installers gain full visibility into the performance of individual strings and sub-arrays without having to build out extra network infrastructure. An optional stainless steel enclosure and dust filter make the unit resilient in industrial and agricultural environments. The PVI KW series answers the needs of commercial system integrators and solar farm developers who want a reliable, scalable solution with high resistance to grid and environmental conditions.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.2% Not published -
MPPT trackers - 4 Not published -
Max DC input voltage 600 V 1100 V Weak · bottom 1% 519
Weight per kW 11.6 1.2 Weak · bottom 1% 514
Warranty 5 yrs 5 yrs Typical 45
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 60 kW Continuous output
Phases Three-phase
Nominal AC voltage 480 V -12%/+10%
Max AC current 264.0 A
Grid frequency 60 Hz Range 59.3-60.5 Hz
Power factor Unity, >0.99
Harmonic distortion (THD) 3.0 %
Max DC voltage 600 V Caps the string length
MPPT voltage range 312 to 500 V
Max efficiency 96.5 % Best single operating point
CEC efficiency 95.5 % California Energy Commission weighting
Dimensions 1930 × 1422 × 744 mm Height × width × depth
Weight 694.0 kg 11.6 kg per kW
Enclosure NEMA 3R
Operating temperature -25 to 50 °C
Max humidity 95 %
Interfaces Display
Protocols MODBUS
Protection DC switch
Warranty 5 years Standard manufacturer cover
Certifications UL 1741IEEE 1547IEEE 1547.1IEEE 62.41.2IEEE 62.45IEEE C37.90.2CSA C22.2#107.1FCC part 15 B

Pros and cons

5 positive · 3 caution
What owners get
Transformer-based galvanic isolation

The built-in transformer improves galvanic safety and resilience on unstable grids compared to transformerless competitors of that era, which mattered for commercial and agricultural installations on weaker infrastructure.

Voltage flexibility 208/240/480/600 VAC

A single unit supports four AC grid voltage standards, eliminating the need for separate regional variants and simplifying work for integrators across different installation markets.

Integrated AC/DC disconnects

Built-in disconnects reduce the number of BoS components and shorten installation time compared to models requiring separate disconnect enclosures, directly lowering labor costs.

Advanced grid support features

Active/reactive power control, voltage/frequency ride-through, and remote curtailment made it easier to meet grid operator requirements (e.g., IEEE 1547) on multi-megawatt projects, an advantage over simpler commercial inverters from that period.

Remote monitoring via MODBUS and cellular modem

A built-in cellular modem and MODBUS communication gave full visibility into string-level performance without building extra on-site network infrastructure, cutting monitoring deployment costs.

Trade-offs
Production discontinued in 2017

The PVI KW series was discontinued in 2017 (Q4 2017) following Yaskawa's acquisition of Solectria, meaning limited availability of spare parts and warranty service for existing installations.

Bulky transformer-based design

The AC transformer increases weight and footprint compared to newer transformerless competitors (e.g., the later XGI series), raising transport and installation costs and lowering conversion efficiency by roughly 1-2 percentage points.

Dated communication platform

Monitoring relying solely on MODBUS and a dedicated cellular modem, without native cloud/app integration, is outdated compared to the IoT platform standards used in newer commercial series.

Inverter Power Euro eff. MPPT Weight Difference
Solectria PVI 60KW 60 kW - - 694.0 kg You are here
SUN2000-60KTL-M0 60 kW 98.7% 6 74.0 kg 620.0 kg lighter
SG60KTL-182 60 kW 98.7% 1 60.0 kg 634.0 kg lighter
GW60KN-MT 60 kW 98.5% 4 64.0 kg 630.0 kg lighter
Solis-60K-4G 60 kW 98.5% 4 63.0 kg 631.0 kg lighter
BNT060KTL 60 kW 98.5% - 51.0 kg 643.0 kg lighter
XG60KTR 60 kW 98.5% 4 50.0 kg 644.0 kg lighter
XG60KTRL 60 kW 98.5% 4 50.0 kg 644.0 kg lighter
MAX 60KTL3 LV 60 kW 98.4% - 82.0 kg 612.0 kg lighter

About the PVI KW series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Is the Solectria PVI KW inverter series still available for purchase?
No, the PVI KW series has been discontinued by Solectria (now Yaskawa-Solectria) and is listed in the manufacturer's discontinued products archive. For new commercial and utility-scale projects, consider successor lines such as the PVI TL series, which carry forward the advanced grid-support functions. Service and spare parts for existing PVI KW installations may still be available through authorized distributors, but on a wind-down support basis.
What is the maximum power output of the Solectria PVI KW inverters?
The PVI KW family covered models rated from 50 kW to 100 kW in a single enclosure, allowing projects to scale without switching hardware platforms. This made the units suitable for both large commercial rooftop installations on industrial buildings and the first build-out phases of multi-megawatt solar farms assembled from several units.
What grid voltages does the Solectria PVI KW inverter support?
The PVI KW series operates across three grid configurations: 208, 240, 480, and 600 VAC, letting one inverter model fit different voltage standards common in industrial and commercial installations without an intermediate transformer. This flexibility let integrators standardize on a single model across projects built in different locations and electrical infrastructures.
What does transformer isolation provide in the PVI KW inverters, and is it an important feature?
Transformer isolation galvanically separates the DC and AC sides, improving safety and stabilizing operation during grid voltage fluctuations or utility-side disturbances. In practice, this means lower susceptibility to damage from unstable grid conditions, which mattered for commercial and farm-scale projects where downtime translates into measurable financial losses.
Does installing a PVI KW inverter require additional AC and DC disconnects?
No, PVI KW inverters include integrated AC and DC disconnects in the enclosure, eliminating the need to buy and mount separate disconnect boxes as additional BoS (Balance of System) components. This shortens installation time, reduces the number of cable connections prone to failure, and lowers overall project cost compared to solutions requiring external disconnects.
How can I monitor individual string performance in a PVI KW installation?
PVI KW inverters communicate over the MODBUS protocol and include a built-in cellular modem, giving installers full visibility into each string's and subsystem's performance without building additional on-site monitoring infrastructure. This was particularly useful for distributed solar farms, where visiting each unit for diagnostics would otherwise be time-consuming and costly.