Skip to main content

Solectria PVI 3000S

3 kW Grid-tie
Datasheet PDF
Rated AC (kW)
3.00
Strong · top 21%
Euro eff. (%)
-
Not published
MPPT
-
Not published
Max DC (V)
600
Typical · median 550 V
Weight (kg)
22.2
Typical · median 10.8 kg
Warranty (yrs)
10
Strong · top 15%

The PVI-S series from Solectria Renewables is built for installers who value straightforward mounting and serviceability over chasing marginal efficiency gains. Five power ratings make it easy to match the inverter precisely to a rooftop or ground-mount array size without oversizing the system. A defining feature of the design is transformer isolation, which adds galvanic safety and operating stability under tougher grid conditions, a benefit commercial project owners particularly value. A practical touch comes from the detachable wiring box with an integrated string combiner, letting electricians wire up the DC side without opening the main electronics enclosure, cutting installation time and reducing the risk of errors. The wide MPPT voltage window allows flexible string configurations even as irradiance shifts throughout the day. The package is rounded out by a built-in LCD display, RS485 communication, and optional web-based monitoring for easier remote diagnostics. For larger sites, an integrated panel assembly combining up to two inverters is also available. The standard 10-year warranty further lowers operating risk over the system's service life.

Ranking

449 inverters up to 3 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 96.9% Not published -
MPPT trackers - 1 Not published -
Max DC input voltage 600 V 550 V Typical 41
Weight per kW 7.4 5.5 Typical 295
Warranty 10 yrs 5 yrs Strong · top 15% 8
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 3 kW Continuous output
Max AC current 13.5 A
Grid frequency 60 Hz Range 59.3-60.5 Hz
Power factor Unity, >0.99
Harmonic distortion (THD) 3.0 %
Max DC voltage 600 V Caps the string length
MPPT voltage range 200 to 550 V
Start-up voltage 210 V
Max efficiency 96.7 % Best single operating point
CEC efficiency 96.0 % California Energy Commission weighting
Dimensions 732 × 454 × 175 mm Height × width × depth
Weight 22.2 kg 7.4 kg per kW
Enclosure Type 3R
Operating temperature -25 to 50 °C
Max humidity 95 %
Interfaces Display
Protocols RS485
Protection DC switch
Warranty 10 years Standard manufacturer cover
Certifications UL 1741IEEE 1547IEEE 1547.1CSA C22.2#107.1FCC part 15 B

Pros and cons

5 positive · 2 caution
What owners get
Transformer galvanic isolation

Unlike many competing transformerless string inverters of the same generation, the PVI-S series uses transformer isolation, providing additional DC/AC galvanic separation and better resilience against grid disturbances - a feature favored by commercial investors and certain US grid-interconnection requirements.

Removable junction box with integrated combiner

An integrated string combiner inside a detachable DC junction box lets an electrician complete DC wiring without opening the main electronics enclosure, shortening installation time and reducing the risk of damaging the inverter electronics during setup.

Five power ratings in one product line

Offering five distinct power variants allows precise sizing of the inverter to the rooftop or ground-mount array without oversizing the system, a practical benefit when designing commercial installations of varying scale.

Wide MPPT voltage range

A flexible MPPT voltage range allows more freedom in configuring PV module string lengths, easing string design under varying irradiance conditions throughout the day.

Standard 10-year warranty

The standard 10-year warranty, at the time of launch (2008), exceeded the typical 5-year coverage offered by many commercial inverter manufacturers in this class, lowering the investor's operational risk.

Trade-offs
Production discontinued since 2013

The PVI-S series was discontinued in 2013 (just 5 years after its 2008 launch), meaning limited availability of OEM spare parts and manufacturer service support for existing installations - a risk given the typical 20-25 year operating lifetime of PV systems.

Transformer isolation means lower efficiency and higher weight

The low-frequency transformer topology typically results in lower peak efficiency (usually around 95-96%) and a heavier unit compared to competing transformerless string inverters of the same era (e.g., Fronius, SMA), which reached 97-98% efficiency.

Inverter Power Euro eff. MPPT Weight Difference
Solectria PVI 3000S 3 kW - - 22.2 kg You are here
SolarEdge SE3000H (HD‑Wave, single phase) 3 kW 98.3% - 7.8 kg 14.4 kg lighter
XG3KTR-S 3 kW 98.3% 2 12.0 kg 10.2 kg lighter
SPI3K-B 3 kW 98.0% 2 18.5 kg 3.7 kg lighter
ASW3K-LT-G2 Pro 3 kW 97.9% 2 16.0 kg 6.2 kg lighter
Solis-3P3K-4G 3 kW 97.8% 2 17.3 kg 4.9 kg lighter
T3-M 3 kW 97.8% 2 16.5 kg 5.7 kg lighter
T3-G3 3 kW 97.8% 2 17.0 kg 5.2 kg lighter
X3-MIC-3K-G2 3 kW 97.8% 2 15.5 kg 6.7 kg lighter

About the PVI-S series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Is the Solectria PVI-S inverter series still available for purchase?
No, the PVI-S series has been discontinued and is no longer offered as a new product by Solectria Renewables. Units may still be found on the secondary market or through distributors clearing stock, but buyers should verify warranty service and spare parts availability with the current manufacturer, since technical support for legacy models can be limited.
What is the difference between transformer isolation in PVI-S and transformerless inverters?
Transformer isolation physically separates the DC and AC circuits, providing additional galvanic safety and more stable operation on unstable grids. In practice, this means lower sensitivity to grid disturbances and better protection for commercial installations, though at the cost of slightly greater weight and size compared to lighter transformerless inverters.
How does the detachable junction box with integrated string combiner work on PVI-S?
The junction box detaches from the main electronics enclosure, allowing an electrician to wire the DC side without opening the inverter's internal compartment. The integrated string combiner lets multiple module strings terminate in one place, reducing installation time and wiring errors, which is especially useful on larger systems with numerous PV strings.
What warranty does the PVI-S inverter series come with?
PVI-S inverters shipped with a standard 10-year manufacturer warranty, a competitive term for this class of equipment when the series launched. Since the line is now discontinued, buyers sourcing units from the secondary market should confirm how much warranty coverage remains and whether it transfers to a new system owner.
Can two PVI-S units be mounted on a single rack?
Yes, for larger installations an integrated mounting panel was available that could hold up to two PVI-S inverters at once. This setup helps organize technical space in commercial buildings where several units are installed close together, and it speeds up installation compared to mounting each inverter on separate individual brackets.
How can a PVI-S inverter be monitored remotely?
PVI-S featured a built-in LCD display for on-site readings and RS485 communication for connecting to supervisory systems. An optional web-based monitoring platform allowed tracking energy production and system status remotely, simplifying fault diagnosis without requiring a site visit for every check.